Type SE, Style SEU Service Entrance Cable. 600 Volt. Individual Conductors Rated XHHW-2 or THHN/THWN. Jacket and Individual Conductors Sunlight Resistant.
Southwire® Type SE, Style SEU service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating is 600 volts.
Conductor | Neutral Wire | Allowable Ampacities | ||||||||||||
Size (AWG or kcmil) AWG or kcmil mm2 | No. of Conductors | No. of Strands | Size (AWG) | No. of Neutrals | No. of Strands | Nom. Width (mils) (mm) | Nom. Height (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Insulation Thickness (mils) (mm) | Allowable Ampacity at 60C | Allowable Ampacity at 75C | Allowable Ampacity at 90C | Allowable Ampacity in Dwelling | |
130757 |
10 AWG
10 AWG
|
2
2
|
1
1
|
10
10
|
1
1
|
12
12
|
447
11.37
|
297
7.56
|
131
195
|
20
0.51
|
30
30
|
30
30
|
30
30
|
|
130765 |
8 AWG
8 AWG
|
2
2
|
7
7
|
8
8
|
1
1
|
8
8
|
596
15.14
|
384
9.75
|
210
312
|
30
0.76
|
40
40
|
50
50
|
60
60
|
|
130815 |
6 AWG
6 AWG
|
2
2
|
7
7
|
8
8
|
1
1
|
8
8
|
673
17.10
|
425
10.80
|
286
425
|
30
0.76
|
55
55
|
65
65
|
75
75
|
|
130773 |
6 AWG
6 AWG
|
2
2
|
7
7
|
6
6
|
1
1
|
12
12
|
673
17.10
|
425
10.80
|
316
471
|
30
0.76
|
55
55
|
65
65
|
75
75
|
|
130823 |
4 AWG
4 AWG
|
2
2
|
7
7
|
6
6
|
1
1
|
12
12
|
807
20.50
|
492
12.50
|
424
631
|
45
1.14
|
70
70
|
85
85
|
95
95
|
100
100
|
130781 |
4 AWG
4 AWG
|
2
2
|
7
7
|
4
4
|
1
1
|
12
12
|
836
21.24
|
521
13.24
|
490
729
|
45
1.14
|
70
70
|
85
85
|
95
95
|
100
100
|
130831 |
3 AWG
3 AWG
|
2
2
|
7
7
|
5
5
|
1
1
|
15
15
|
861
21.87
|
519
13.18
|
521
775
|
45
1.14
|
85
85
|
100
100
|
110
110
|
110
110
|
130799 |
3 AWG
3 AWG
|
2
2
|
7
7
|
3
3
|
1
1
|
12
12
|
902
22.92
|
560
14.23
|
592
881
|
45
1.14
|
85
85
|
100
100
|
110
110
|
110
110
|
130849 |
2 AWG
2 AWG
|
2
2
|
7
7
|
4
4
|
1
1
|
12
12
|
952
24.19
|
579
14.71
|
656
976
|
45
1.14
|
95
95
|
115
115
|
130
130
|
125
125
|
130807 |
2 AWG
2 AWG
|
2
2
|
7
7
|
2
2
|
1
1
|
15
15
|
964
24.49
|
591
15.02
|
730
1086
|
45
1.14
|
95
95
|
115
115
|
130
130
|
125
125
|
218263 |
1 AWG
1 AWG
|
2
2
|
19
19
|
1
1
|
1
1
|
14
14
|
1101
27.98
|
670
17.03
|
915
1362
|
55
1.40
|
110
110
|
130
130
|
150
150
|
150
150
|
218289 |
2/0 AWG
2/0 AWG
|
2
2
|
19
19
|
2/0
2/0
|
1
1
|
18
18
|
1289
32.76
|
775
19.70
|
1428
2126
|
55
1.40
|
145
145
|
175
175
|
195
195
|
200
200
|