LNP8SD, LONGNOSE PLIER 8" 12AWG DIP p-58289740 58289740

Southwire #: 58289740 Model #: LNP8SD

These durable, high-performing long nose pliers are built from forged steel and are fitted with dipped handles. Designed to reach tight spaces. The hi-leverage, hot-riveted joint is guaranteed to provide long-lasting durability and performance

Download Category Specifications
Excel Table
Register Product
Register Product

Features & Benefits

  • HEAVY DUTY long-nose pliers perfect for accessing cramped spaces where full sized tolls won’t reach to get the job done
  • Strips 12 AWG solid insulated wire.
  • DURABLE Induction Hardened cutting blades ensure efficient and lasting cutting surfaces for hard and soft wire
  • STRONG serrated jaws for optimal holding and gripping results
  • Hot riveted pivot joint for smooth action and no wobble

Specifications

Model # LNP8SD LNP8SD
UPC # 032886911019 032886911019
Product Height 8.5 21.59 inch cm
Product Width 2.1 5.33 inch cm
Depth 0.614 1.56 inch cm
Product Weight 0.64 0.29 lbs kg
Warranty Lifetime No Hassle Warranty Lifetime No Hassle Warranty
Handle Grip Dipped Grip Dipped Grip

Resources

There are no downloadable resources for this product.
Rated 4 out of 5 by from Quality tool Look at the size! This is a serious long nose plier. At 8 inches they are longer than most, and the length is not all in the nose. The handles are most of the length, giving these pliers good leverage for cutting or gripping. The cushioned handles are thick and do a good job. There is a #12 wire stripper built in the cutter, which some may find useful. I thought perhaps it would make these my go-to pliers for working for working with #12 NM. With a Romex stripper, I thought you could do it all. But I found that the stripping gap prevents a clean cut of the jacket. So if you think you need the full width of the cutter, you may find the gap gets in the way. But if you are working with individual wires, these pliers will work great for you. The rounded edges form a perfect eye on solid wires, and the serrated jaws grip tightly. Fit and finish is great with good simultaneous full closure of the nose and the cutter. I'll grab these first, even though I'm not crazy about the wire stripper.
Date published: 2017-03-19
Rated 5 out of 5 by from High Quality Feel The most important quality in a hand tool is how it feels in your hand - these long nose pliers feel great! The handle is comfortable without being bulky. The weight is balanced properly and the tips are well aligned for a tight, secure grip. This is a professional quality too.
Date published: 2017-03-20
Rated 5 out of 5 by from 8" Heavy Duty Needle Nose Pliers The needle nose pliers are very well built and have a smooth action. The cutting blade is very precise and the 12 gauge wire stripper comes in very handy. These are especially nice to use when making up solid wire where you need to bend it around a termination screw.
Date published: 2017-03-20
Rated 5 out of 5 by from Great product. Solid value. What can I say about a pair of needle nose pliers? Either they are junk or not and these most definitely are not. Once I got them loosened up to my liking I was completely sold. Grip, stripping hole, and cutters all are great. You can't go wrong.
Date published: 2017-03-16
Rated 5 out of 5 by from Better than "Klein T...s" Been using it for 2 weeks now. Love the feel. I used it to get in a crammed J box to pull out a damaged wire. Did not loose grip of the wire and no matter how hard I pulled the dipped grips stayed in place. Glad it's in my tool pouch.
Date published: 2017-03-23
Rated 5 out of 5 by from Greeat overall features! I received this just yesterday and already have put it to good use. The weight of the tool is just right along with how it feels as I'm holding it. It has the ability to strip 12 gauge wire as well.
Date published: 2017-03-14
Rated 5 out of 5 by from Quality!! This tool is quality, as soon as you feel it in your hand you know its a well made tool. It doesn't reinvent the wheel but because of its quality it feels good and gives the user confidence.
Date published: 2017-03-17
Rated 5 out of 5 by from High Quality Long Nose Pliers I'm really happy with my long nose pliers. They are solid. The handle is comfortable and I really like the ability to strip wire with the tool also. Strongly recommend.
Date published: 2017-03-20
Rated 5 out of 5 by from Great Product and Features I received these pliers a month ago and have not used any others. These needle nose are manufactured very well are my new go to when I am in need of a precision tool.
Date published: 2017-04-10
Rated 5 out of 5 by from 8 inch needle nose pliers I've had them for about a week now. Very comfortable in hand and seem to be very aldirable.Definitely very good needle nose for the price that's for sure.
Date published: 2017-03-23
Rated 4 out of 5 by from 8" Heavy Duty pliers My only problem is i think the teeth/metal head are a little to fine . I would like to see a bit more depth for holding power on twisting wires and such .
Date published: 2017-03-24
Rated 4 out of 5 by from Turned out good After I finally cleaned off all the preservative, especially on the plastic handles, these pliers turned into a dependable tool that I use every day.
Date published: 2017-03-23
Rated 5 out of 5 by from Real sturdy and sharp. This a very well built, I have been very impressed all of Southwires products and this one is no exception it meets and exceeds my expectations.
Date published: 2017-04-05
Rated 5 out of 5 by from Great design Comes in handy for terminating panels. Wire strip notch works good for #12 & #14 wire. Handle is good size for comfortable grip. Great design.
Date published: 2017-03-17
Rated 3 out of 5 by from Okay for price They are okay. Not great quality as one of the handles is deformed. They are loose out of packaging and have a built in #12 stripper.
Date published: 2018-05-07
Rated 5 out of 5 by from Good quality Good quality tool for the amount of money, good firm pinch at the tip, nice clean cutting and feels comfortable in your hand...
Date published: 2017-03-21
Rated 5 out of 5 by from Well built The Needle Nose seem very well built and heavy duty. The cutters and wire stripper work very well. Everything I could ask
Date published: 2017-03-16
Rated 5 out of 5 by from Workes as it should I particularly like the stiffness of the jaws in that they resist twist and the serrations hold well.
Date published: 2017-03-21
Rated 4 out of 5 by from Very heavy duty. Product is heavy dire and feels heavy in your hand. Cuts well and is a good size. Highly recommend!
Date published: 2017-03-23
Rated 5 out of 5 by from Great Tool! It is a great product at a great price. With a life time guarentee, you cant go wrong!
Date published: 2017-03-21
Rated 4 out of 5 by from Works good The tip has great holding power. The grips are very good and you can strip wires too
Date published: 2017-04-13
Rated 4 out of 5 by from Great Tool! Overall the tool is great. We enjoy the build in strippers. Feels good in your hand.
Date published: 2017-03-16
Rated 5 out of 5 by from great product these pliers have a great grip and length,comfortable to use.Good sharp cutter also
Date published: 2017-03-16
Rated 4 out of 5 by from Long nose plier I found this tool very well made. And it worked nice.i would give it a thumbs up.
Date published: 2017-03-16
Rated 4 out of 5 by from Perfect size I've used this on several occasions and seems to perform to my expectations
Date published: 2017-03-16
Rated 4 out of 5 by from Great Tool The Cutting Jaws are great, very easy to cut. Jaws are symmetrical.
Date published: 2017-07-17
Rated 5 out of 5 by from Really works well Glad I got these works great for me. Really like the way they work
Date published: 2017-03-17
Rated 5 out of 5 by from Best thing yet Would recommend to someone in any trade can’t get enough of them
Date published: 2018-05-07
Rated 5 out of 5 by from Very well made tool Very nice pair of pliers, well made and does the job every time.
Date published: 2017-07-16
Rated 4 out of 5 by from Good quality This is a very good quality product. Works well stripping wire.
Date published: 2017-04-13
  • y_2026, m_3, d_8, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_41
  • loc_en_US, sid_58289740, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_southwiretools
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 8ms
  • REVIEWS, PRODUCT
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 31ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;