Southwire Product Catalog

 

Our Product Catalog Download requires WinZip file archiving software. Download Winzip

Click here to show/hide usage instructions.
  • Product group offerings are viewed by clicking on the product group description or on the plus symbol next to the folder icon. This will expand and collapse the product group.
  • A product quick view is obtained by hovering over the product item image. This will display product summary information.
  • A complete product page is viewed by clicking on the product item in the expanded list. This will open the catalog page in a PDF file format.
  • To download multiple pages, click on the box in front of the product pages or groups and then click on "Download Products" found at the top and bottom of the product listing. The selected pages will be downloaded as a zipped file to your computer.
  • To narrow product groups, select a filter from the dropdown listbox.
  • XHHW Aluminum
    • 600 Volt. AlumaFlex® Aluminum Alloy (AA-8176) Conductor.
    • Cross-linked Polyethylene (XLP) Insulation.
    • High-Heat and Moisture Resistant.
    • Sunlight Resistant in Black Sizes 2 AWG and Larger.
    XHHW Aluminum
  • AL-RHH or RHW or USE
    • Underground Service Entrance Cable. 600 Volt.
    • AlumaFlex® Aluminum Alloy (AA-8176) Conductor.
    • Cross-linked Polyethylene(XLP) Insulation.
    • High-Heat, Moisture, and Sunlight Resistant.
    • Rated SIS in #8 - 4/0 AWG.
    AL-RHH or RHW or USE
  • Mobile Home Feeder
    • Underground Service Entrance Cable
    • 600 Volt
    • AlumaFlex® Aluminum Alloy (AA-8176) Conductors
    • Cross-linked Polyethylene (XLP) Insulation
    • Sunlight Resistant
    Mobile Home Feeder
  • Aluminum SE Cable
    • Type SE, Style SER and SEU Service Entrance Cable
    • 600 Volt. AlumaFlex® Aluminum Alloy (AA-8176) Conductors
    • Individual Conductors Rated XHHW or THHN/THWN
    • Jacket and Inner Conductors are Sunlight Resistant
    Aluminum SE Cable
  • SIMpull THHN® Cable with AlumaFlex® Conductors
    • 600 Volts
    • AlumaFlex® Aluminum (AA-8176) Conductor
    • Thermoplastic Insulation / SIM Nylon Sheath
    • Heat, Moisture, Gasoline, and Oil Resistant II, Sunlight Resistant
    • Also Rated THWN-2
    • SIM Technology® for Easier Pulling
    SIMpull THHN® Cable with AlumaFlex® Conductors
  • Primary Wire SXL
    • Stranded bare or copper conductors
    • PVC Insulation.
    • 125°C, 60 Volts.
    Primary Wire SXL
  • Primary Wire GPT
    • Stranded bare or copper conductors
    • Premium PVC Insulation.
    • 85°C, 60 Volts.
    Primary Wire GPT
  • SGT/SGR/SGX Battery Cable
    • Stranded bare copper with PVC, Rubber, TPR or Cross-Link Insulation.
    • 85°C (SGT), 90°C (SGR), 125°C (SGX). 60 Volts.
    SGT/SGR/SGX Battery Cable
  • Brake Cable
    • Stranded Bare or Tinned Copper Conductors.
    • 85°C and 105°C, 50 Volts.
    Brake Cable
  • Booster Cable
    • Stranded bare copper with PVC and TPE Insulation
    • 85°C and 105°C, 50 Volts
    Booster Cable
  • Trailer Cable
    • Stranded bare copper conductors with PVC,
    • Rubber or TPR insulation;
    • twisted with overall jacket.
    • 60°C, 90°C, 105°C;-40°C, -65°C.
    Trailer Cable
  • MCAP -PCS Duo™
    • Circuit identification printed directly on the armor
    • Available in 250’ coils, 1000’ reels, barrels, boxes, or prefab assemblies
    • UL 83, 1685, and 1569 compliant (Including new Sections 9.4, 40.1(q), and 41.1(r) as detailed in the latest UL 1569 CRD)
    • Environmental air-handling spaces per NEC 300.22 (C)
    • Places of Assembly per NEC 518.4 and theaters per NEC 520.5
    • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2)
    MCAP -PCS Duo™
  • Armorlite® Type MC PVC Jacketed Neutral Per Phase

    A dedicated neutral conductor for each phase conductor for compliance with NEC 210.7.
    Reduces installation costs up to 50% over pipe and wire.
    UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121,W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
    Anti-short bushings are not required for use with MC cable per the NEC and UL

    Armorlite® Type MC PVC Jacketed Neutral Per Phase
  • Armorlite® Type MC Neutral Per Phase
    • Lightweight Aluminum Interlocked Armor. 600 Volts.
    • Copper Power Conductors.THHN/THWN Insulated Singles.
    • Dedicated Neutral Conductor for Each Phase Conductor.
    • Insulated GroundingConductors.
    • Sizes 14 AWG and 8 AWG. RatedVW-1.
    Armorlite® Type MC Neutral Per Phase
  • Armorlite® Type MCAP Multi-Circuit

    Reduces installation costs up to 50% over pipe and wire.
    Lightweight aluminum armor--as much as 45% lighter than steel MC Cable.
    UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
    Anti-short bushings are not required for use with MC cable per the NEC and UL

    Armorlite® Type MCAP Multi-Circuit
  • Armorlite ® Type MC
    • Lightweight Aluminum Interlocked Armor. 600 Volts
    • Copper Power Conductors. THHN/THWN Insulated Singles
    • Green Insulated Grounding Conductor
    • Sizes 14 AWG through 2 AWG. Rated VW-1
    Armorlite ® Type MC
  • Armorlite ® Type MC - Isolated Ground
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • Copper Power Conductors.
    • THHN/THWN Insulated Singles.
    • Two Insulated Grounding Conductors.
    • Sizes 12 AWG and 10 AWG.
    • Rated VW-1.
    Armorlite ® Type MC - Isolated Ground
  • Armorlite ® Type MC - Oversized Neutral
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • Copper Power Conductors.
    • THHN/THWN Insulated Singles.
    • Oversized Neutral Conductor.
    • Green Insulated Grounding Conductor.
    • Sizes 12 AWG and 10 AWG.
    • Rated VW-1.
    Armorlite ® Type MC - Oversized Neutral
  • Armorlite ® Type MC - Multi-Circuit
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • Copper Power Conductors.
    • THHN/THWN Insulated Singles.
    • Multiple Circuits.
    • Green Insulated Grounding Conductor.
    • Sizes 12 AWG and 10 AWG.
    • Rated VW-1.
    Armorlite ® Type MC - Multi-Circuit
  • Armorlite ® Type MC - PVC Jacketed
    • Lightweight Aluminum Interlocked Armor with Overall PVC Jacket.
    • 600 Volts.
    • Copper Power Conductors.
    • THHN/THWN Insulated Singles.
    • Sunlight Resistant.
    • Green Insulated Grounding Conductor.
    • Sizes AWG 14 through AWG 2. Rated VW-1.
    Armorlite ® Type MC - PVC Jacketed
  • Armorlite ® Type AC
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • Copper Power Conductors.
    • Type ACTHH (THHN Singles).
    • 16 AWG Aluminum Bond Wire.
    • Sizes 14 AWG through 2 AWG.
    Armorlite ® Type AC
  • Duraclad® Type AC

    An armor assembly (combination of the interlocked armor & bonding strip) that is recognized as an equipment grounding/bonding conductor per NEC 250.118(8).
    Reduces installation costs up to 50% over pipe and wire.
    Anti-short/insulating bushings supplied with every reel or coil.
    Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.

    Duraclad® Type AC
  • Duraclad® Type AC-HCF Steel Armor Health Care Facility
    • An armor assembly (combination of the interlocked armor & bonding strip) that is recognized as an equipment grounding conductor per the NEC 250.118(8) and 517.13(A).
    • An insulated equipment grounding conductor sized per NEC 517.13(B) and Table 250.122.
    • Reduces installation costs up to 50% over pipe and wire.
    • Anti-short/insulating bushings supplied with every reel or coil.
    Duraclad® Type AC-HCF Steel Armor Health Care Facility
  • Duraclad HCF MC AP Type MC All Purpose Health Care Facility

    Meets UL Product Category PJAZ (Metal-Clad Cable) and provides redundant equipment grounding conductors (as defined in NEC® 250.118) as required in NEC® 517.13(A) & (B).
    Installation instructions included with every reel and coil.
    Simplified armored product application and installation.
    Reduces installation costs up to 50% over pipe and wire.
    Increased labor savings compared to Type AC HCF.
    Easy to identify green armor.

    Duraclad HCF MC AP Type MC All Purpose Health Care Facility
  • Duraclad® MC-PCS Duo™

    MC-PCS Du o™ Cable is constructed with 12 AWG or 10 AWG CU Type THHN/THWN power and ground conductors along with a control conductor assembly composed of a 30 mil PVC jacket covering two 16 AWG CU Type TFN control conductors. The phase conductors, ground,

    Duraclad® MC-PCS Duo™
  • Duraclad ® Type BAG Bare Armored Ground Cable
    • Steel Interlocked Armor.
    • Bare Copper Ground.
    Duraclad ® Type BAG Bare Armored Ground Cable
  • Duraclad Type MC - Lightweight Steel Armor
    • Lightweight Steel Interlocked Armor. 600 Volts
    • Also available in Blue Steel Armor
    • Copper Power Conductors. THHN/THWN Insulated Singles
    • Green Insulated Grounding Conductor
    • Sizes 14 AWG through 10 AWG. Rated VW-1
    Duraclad Type MC - Lightweight Steel Armor
  • HCF MCAP Type MC All Purpose Hospital Care Facility
    • Green Lightweight Aluminum Interlocked Armor.
    • 600 Volt.
    • Copper THHN Insulated Conductors and Green Insulated Ground Conductor.
    • Full-Sized Aluminum Equipment Grounding/Bonding Conductor.
    • Sizes 12 AWG through 10 AWG.
    • UL Listed. Rated VW-1
    HCF MCAP Type MC All Purpose Hospital Care Facility
  • MC-PCS Duo™ PVC Jacketed Power & Control/Signal Cable

    Full compliance with NEC 330, NEC 725, and UL 1569
    16 AWG signal wiring for 0-10V dimming.
    Available in 250’ coils or 1000’ reels
    Available with steel armor
    UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L- 3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065,C-AJ- 4066, F-C-3038.
    Anti-short bushings are not required for use with Type MC Cable per the NEC and UL.

    MC-PCS Duo™ PVC Jacketed Power & Control/Signal Cable
  • MC-PCS Duo™ Power & Control / Signal Cable
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts. Copper Power & Control Conductors.
    • THHN/THWN & TFN Insulated Singles.
    • Green Insulated Grounding Conductor.
    • Power: 12 AWG & 10 AWG.
    • Control: 16 AWG.
    • Rated FT4/IEEE 1202. Rated 90°C Dry Locations.

    For more information, visit http://mcpcsduo.southwire.com/.

    MC-PCS Duo™ Power & Control / Signal Cable
  • MC-PCS Duo™ 2 Zone & 3 Zone Power & Control/Signal Cable

    • Full compliance with NEC 330, NEC 725, and UL 1569
    • 16 AWG signal wiring for 0-10V dimming.
    • Circuit Identification printed directly on the armor
    • Available in 250’ coils, 1000’ reels, barrels, boxes, or prefab assemblies
    • Available with steel armor
    • Available with overall PVC jacket

     

     

    MC-PCS Duo™ 2 Zone & 3 Zone Power & Control/Signal Cable
  • MC-PCS HCF Duo™ Power & Control/Signal Cable for Healthcare Facilities

    Full compliance with NEC 330, NEC 725, and UL 1569
    Meets UL Product Category PJAZ (Metal-Clad Cable) and provides redundant equipment grounding conductors (as
    defined in NEC® 250.118) as required in NEC® 517.13(A) & (B).
    Installation instructions included with every reel and coil
    Circuit identification printed directly on the armor
    Armor ground path is approximately 3.5 times better than Type AC HCF Cable and is equivalent to a green insulated copper grounding conductor.

    MC-PCS HCF Duo™ Power & Control/Signal Cable for Healthcare Facilities
  • MCAP Type MC All Purpose
    • Lightweight Aluminum Interlocked Armor. 600 Volt. Copper THHN Insulated Conductors
    • Full-Sized Aluminum Equipment Grounding/Bonding Conductor. UL Listed. Rated VW-1
    MCAP Type MC All Purpose
  • Multi Circuit MC PVC JKT

    Reduces installation costs up to 50% over pipe and wire.
    UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160,C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038 Anti-short bushings are not required for use with MC cable per the NEC and UL
    Multi Circuit MC PVC JKT
  • PVC Jacketed MCAP HCF ALUMINUM ARMOR
    • 14 AWG through 8 AWG Copper THHN Insulated Conductors and Green Insulated Ground Conductor.
    • Full-Sized Aluminum Equipment Grounding/Bonding Conductor.
    • UL Listed.
    • 600 Volts.
    • Rated VW-1.
    • Green Lightweight Aluminum Interlocked Armor is Part of Equipment Bonding/Grounding Path.
    • Sunlight Resistant, Direct Burial Overall PVC Jacket.

     

    PVC Jacketed MCAP HCF ALUMINUM ARMOR
  • Red Alert ® Type MC - Fire Alarm and Control
    • Red Lightweight Aluminum Interlocked Armor.
    • 600 Volt Type MC and 300 Volt Type FPLP.
    • Plenum Rated.
    • Solid Copper Conductors.
    • Sizes 14 & 12 AWG Type THHN/THWN VW-1 Singles.
    • Sizes 18 &16 AWG Type TFN VW-1 Singles.
    • Green Insulated or Tinned Copper Grounding Conductor.
    • 6/C and 8/C constructions are NOT Plenum Rated.
    Red Alert ® Type MC - Fire Alarm and Control
  • AC90 - Aluminum
    • 8000 Series ACM aluminum conductors
    • CSA Standard C22.2, No. 51 - armoured cables
    • CSA Certified file listing: LL90458, CLASS 581801 – armoured cable
    • CSA -40°C cold temperature rating
    • CSA -10°C minimum recommended cold temperature
    • installation temperature
    • XLPE Insulation
    • Temperature rating of conductors is 90°C (maximum) 
    • Aluminum interlocked armour
    • 600V insulation rating
    AC90 - Aluminum
  • AC90 Copper
    • Copper Conductors
    • 14 to 6 AWG, 600 Volts
    • 90°C; -40°C
    • XLPE insulation
    AC90 Copper
  • AC90 ISO-BX Copper
    • Copper Conductors, XLPE Insulation
    • 14 to 10 AWG, 600 Volts
    • 90°C; -40°C
    AC90 ISO-BX Copper
  • AC90AG

    Southwire’s AC90AG™ cables meet or exceed the following requirements:

    • CSA Spec. C22.2 No. 51 - Armoured Cables
    • CSA File Listing: LL90458
    • CSA -40°C Cold Temperature Rating
    • CSA -10°C Minimum recommended cold installation temperature
    • XLPE Insulation
    AC90AG
  • ACIC-PCS DUO™ - Power & Control/Signal Cable - CSA

    Southwire’s ACIC-PCS DUOTM cables meet or exceed the following requirements:

    • CSA Certification File: LL90458
    • CSA Standard C22.2 No. 239 - Control and Instrumentation Cables
    • CSA 90°C Max. Insulation Temperature rating
    • CSA -25°C Cold Temperature Rating
    • CSA -10°C Minimum recommended cold Installation Temperature
    • CSA - FT1 & FT4 Flame Test ratings
    • Class - C572101 - Control Cables
    ACIC-PCS DUO™ - Power & Control/Signal Cable - CSA
  • Annunciator (Bell) Wire
    • Soft bare copper conductors, thermoplastic insulation.
    • Multiple conductors are twisted.
    • 105°C, 30 Volts.
    Annunciator (Bell) Wire
  • Battery Cable
    • Stranded bare copper with PVC, Rubber, TPR or Cross-link Insulation
    • 85°C, 90°C, 125°C. 50 Volts
    • RoHS
    Battery Cable
  • Blasting Cable
    • Stranded Copper Conductors
    • Neoprene rubber insulation. 60°C
    • RoHS
    Blasting Cable
  • Booster Cable (Twin)
    • Stranded bare copper with PVC, rubber or TPR insulation
    • 90°C, 50 Volts RoHS
    Booster Cable (Twin)
  • Brake Cable
    • Stranded bare or tinned copper conductors.
    • 105°C, 50 Volts.
    Brake Cable
  • CL 1251/AWM 3173
    • Solid or Stranded Soft Bare or Tinned Copper Conductor. XLPE insulation
    • 125°C Normal Operating Temperature. 600 Volts
    • RoHS
    CL 1251/AWM 3173
  • CSA Teck90 Control Cable
    • 1000 V Multiconductor, Teck 90 Cable
    • 14-10 AWG, XLP insulation
    • Aluminum Interlocked Armor
    • Inner and Outer PVC jackets
    • Rated HL (Hazardous Locations)
    CSA Teck90 Control Cable
  • CSA Teck90 Power Cable
    • 1000 V Multiconductor, Teck 90 Cable
    • 8 and larger AWG, XLP insulation
    • Aluminum Interlocked Armor
    • Inner and Outer PVC jackets
    • Rated HL (Hazardous Locations)
    • 600V UL Type MC
    CSA Teck90 Power Cable
  • CU-NMWU
    • Underground Feeder and Branch Circuit Cable.
    • 300 Volts. Copper Conductors.
    CU-NMWU
  • FAS
    • Solid or stranded bare copper conductors
    • PVC Insulation 105°C, 300 Volts
    • RoHS
    FAS
  • HDT/GPT/TWP
    • Stranded bare or copper conductors
    • PVC Insulation 85°C, 50 Volts
    • RoHS
    HDT/GPT/TWP
  • HPN
    • Bare copper conductors,
    • 2 or 3 conductors laid parallel.
    • 90°C, 300 Volts.
    HPN
  • HSJO/SJOW
    • Bare copper conductors;
    • 60 or 90°C, 300 Volts.
    HSJO/SJOW
  • Irrigation Cable
    • Solid bare copper; PVC insulation; twisted without fillers;overall PVC jacket.
    • 60°C, 30 Volts.
    Irrigation Cable
  • LVT
    • Solid or stranded soft bare copper conductors.
    • 105°C, 300 Volts.
    LVT
  • PXT / PXWT / XTW
    • Bare stranded copper, laid parallel with PVC insulation.
    • 60°C, 125 Volts - PXT 300 Volts - PXWT -34°C)
    PXT / PXWT / XTW
  • Romex® SIMpull® NMD90 Copper
    • Non-metallic Sheathed Cable
    • 300 Volts
    • Copper Conductors
    • SIM Jacket™
    Romex® SIMpull® NMD90 Copper
  • Romex® SIMpull® NMD90 Aluminum

    ASTM – Compact and Compressed aluminum conductors

    Ampacities listed are as per Table 4 in the 2012 Canadian Electrical Code Part I

    CSA C22.2 No. 48 – Non-metallic sheathed cable - LL90458

    CSA - FT1 rating

    Romex® SIMpull® NMD90 Aluminum
  • SIMpull®  RW90 Aluminum
    • Single Aluminum Conductor.
    • 600 Volts.
    • 90°C Max, -40°C Min.
    • Sizes 6 and Larger Black is Sunlight Resistant.
    SIMpull® RW90 Aluminum
  • SIMpull® RW90 Copper
    • Copper Conductors
    • XLPE Insulation
    • 600 Volts
    • 90ºC Maximum, -40ºC Minimum
    • Sunlight Resistant in all Colours
    SIMpull® RW90 Copper
  • RWU90 - Aluminum
    • Single Aluminum Conductor.
    • 8 and larger AWG, 1000 Volts.
    • 90°C Max, - 40°C Min.
    RWU90 - Aluminum
  • RWU90 Copper
    • Single Copper Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant (In Black)
    RWU90 Copper
  • SIMpull® RWU90 Copper
    • Single Copper Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant
    SIMpull® RWU90 Copper
  • SIMpull® RWU90 ALUMINUM
    • Aluminum Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant
    SIMpull® RWU90 ALUMINUM
  • SIMpull T90 Copper

    Southwire’s SIMpull® THHN, THWN-2, MTW cables meet or exceed the following requirements:

    • ASTM B3, B8 and B787
    • Built to CSA C22.2 No.75, LL90458
    • -25°C Cold Bend Test Compliant
    • 2018 Canadian Electrical Code
    • CSA FT-1 - Flame Test
    • UL, c(UL) and CSA listed
    • RoHS/REACH Compliant
    SIMpull T90 Copper
  • SIMpull® T90 ALUMINUM

    Southwire’s SIMpull® T90 cables meet or exceed the following requirements:

    • ASTM
    • CSA C22.2 No. 75, LL90458
    • 2018 Canadian Electrical Code Part I
    • Optional: CSA FT1 flame test rating
    • Optional: -40°C rating
    • RoHS/REACH Compliant
    SIMpull® T90 ALUMINUM
  • SIS
    • Bare or tinned solid or stranded copper.
    • 90°C, 600 Volts.
    SIS
  • Speaker Cable
    • Bare or tinned stranded copper
    • Parallel clear or opaque PVC Insulation.
    • Two Copper Conductors.
    Speaker Cable
  • SPT-1, SPT-2, SPT-3
    • Rated 300 Volts. Rated 105°C
    • Stranded Copper Conductors
    • Thermoplastic Insulation
    • RoHS
    SPT-1, SPT-2, SPT-3
  • STW
    • Bare copper conductors
    • Thermoplastic insulation
    • 60 or 105°C for ST, -34°C for STW
    • 600 Volts
    STW
  • Submersible Pump Cable
    • Solid or stranded bare copper conductors;
    • individuals PVC insulation;
    • 3 or 4 twisted conductors
    • 600 Volts, -40°C.,
    • Maximum 60°C.
    Submersible Pump Cable
  • SXL/GXL/TXL
    • Stranded bare or tinned copper conductors with cross-linked polyethylene insulation.
    • 125°C, 50 Volts.
    SXL/GXL/TXL
  • TEW/AWM 1015/1019/1020/1230 MTW
    • Solid or stranded bare, tinned, or prefused copper
    • Thermoplastic Insulation, 105°C, 600 Volts
    • RoHS
    TEW/AWM 1015/1019/1020/1230 MTW
  • TR32 AWM Style 1013
    • Solid or stranded tinned copper conductors;
    • PVC insulation.
    • 90°C, 600 Volts.
    TR32 AWM Style 1013
  • TR64 AWM 1007
    • Solid or stranded tinned copper conductors
    • PVC insulation. 90°C, 300 Volts.
    • RoHS
    TR64 AWM 1007
  • Trailer Cable
    • Stranded bare copper conductors with PVC,
    • Rubber or TPR insulation; twisted with overall jacket.
    •  60°C, 90°C, 105°C;-40°C, -65°C.
    • RoHS
    Trailer Cable
  • TW75 Copper
    • Copper Conductors
    • 600 Volts
    • Thermoplastic Sunlight Resistant Insulation
    • All Sizes Rated TW75
    TW75 Copper
  • SIMpull® THHN Copper Wire & Cable
    •  600 Volts. Copper Conductor. 
    •  Thermoplastic Insulation/ Nylon Sheath.
    •  Heat, Moisture, Gasoline, and Oil Resistant II.
    • All Sizes Rated Both THHN and either THWN (sizes 14, 12, and 10 AWG) or THWN-2 (sizes 8 AWG and larger).
    • Also Rated MTW and AWM.
    • SIMpull® Technology for Easier Pulling.
    SIMpull® THHN Copper Wire & Cable
  • SIMpull CU-XHHW™
    • 600 Volt
    • Copper conductor
    • Cross-linked polyethylene (XLP) insulation
    • High-heat and moisture resistant
    • SIM Technology® for easier pulling
    • Sizes 14 through 10 AWG also rated SIS
    SIMpull CU-XHHW™
  • CU-RHH or RHW or USE
    • Underground Service Entrance Cable
    • 600 Volt
    • Copper conductors
    • Cross-linked polyethylene (XLP) insulation
    • High-heat, moisture, and sunlight resistant
    • Sizes 6 through 4/0 AWG also rated SIS
    CU-RHH or RHW or USE
  • CU-TFFN
    • 600 Volt.
    • Copper Conductor.
    • Thermoplastic Insulation/Nylon Sheath.
    • Heat, Moisture, Oil, and Gasoline Resistant 1.
    • Also Rated MTW and 105 °C AWM
    • Also Available, TFN and TEWN.
    CU-TFFN
  • Romex® Brand SIMpull® Type NM-B Cable
    • Listed per UL Standard 719
    • UL 83 (Conductor Construction)
    • ASTM B-3 and B-8
    • Federal Specification A-A-59544
    • National Electrical Code, NFPA 70
    • REACH/RoHS Compliant
    Romex® Brand SIMpull® Type NM-B Cable
  • Romex® Brand SIMpull® NM-B-PCS Duo™ Cable

    • Compliant with NEC Article 334 (NM Cable) and the Class 2/Class 3 circuit separation

    requirements of NEC 725.136(I)(1) and 725.136(I)(2)

    • Listed per UL Standard 719

    • ASTM B-3 and B-8

    • Federal Specification A-A-59544

    • REACH/RoHS Compliant

    Romex® Brand SIMpull® NM-B-PCS Duo™ Cable
  • CU-UF-B
    • Underground Feeder and Branch Circuit Cable
    • 600 Volt
    • Copper conductors
    • Sunlight, moisture, and fungus resistant
    • Overall PVC jacket.
    CU-UF-B
  • Copper SE Cable
    • Service Entrance Cable
    • Type SE, Style SER and SE Stype U
    • Service entrance cable
    • 600 Volt
    • Individual conductors rated XHHW-2 or THHN/THWN
    • Jacket and individual conductors
    • Sunlight resistant
    Copper SE Cable
  • Access Control Cable
    • FLAME TEST Riser: UL 1666 Plenum: NFPA 262
    • CABLE TYPE Riser: CMR/CL3R Plenum: CMP/CL3P
    • VOLTAGE 300V
    • TEMPERATURE 75C
    • SUITABLE USE: General purpose low voltage and power-limited systems' circuits to NEC Articles 725 and 800
    • QA UL listed to UL 444 and UL 13

    Access Control Cable
  • Category 5e Cable
    • FLAME TEST CM: UL 1685 /CMR: UL 1666 CMP: NFPA 262
    • CABLE TYPE According to table
    • VOLTAGE 300V
    • TEMPERATURE 75C
    • SUITABLE USE: Where Category 5e cable is specified. General purpose communication circuits to NEC Article 800.
    Category 5e Cable
  • Category 6 Cable
    • CABLE TYPE According to table
    • VOLTAGE 300V
    • TEMPERATURE 75C
    • SUITABLE USE Where Category 6 cable is specified. General purpose communication circuits to NEC Article 800.
    • QA UL listed to UL 444

    Category 6 Cable
  • Broadband Coax- CATV Cable
    • FLAME TEST Non-Plenum Cables: UL 1685 / CSA FT1. Plenum Cables: NFPA 262 / CSA FT6
    • CABLE TYPE Non-Plenum Cables CM RG11 14 AWG are CL3. Plenum Cables: CMP / RG11 14 AWG are CL3P
    • VOLTAGE 300V
    • TEMPERATURE 75C
    • SUITABLE USE: Non-Plenum Cables: In horizontal, non riser and non-plenum use in buildings. Plenum Cables: For use in plenum and risers. Non-UL Cables: For use outdoors, and where cable without a flame rating are permitted.

     

    Broadband Coax- CATV Cable
  • FPLP- Fire Alarm Cable
    • SPECIFICATION UL 1424
    • CABLE TYPE FPLP (NEC / UL)
    • FLAME TEST NFPA 262
    • VOLTAGE 300V
    • TEMPERATURE 75C
    • SUITABLE USE: Fire protectice signaling circuits, smoke detectors, audio, control, and initiating circuits.
    • QA (UL) Listed / (UL) FPLP

    FPLP- Fire Alarm Cable
  • FPLR- Fire Alarm Cable
    • SPECIFICATION
    • CABLE TYPE FPLR (NEC / UL)
    • FLAME TEST UL 1666; FT4
    • VOLTAGE 300V
    • TEMPERATURE 75C
    • SUITABLE USE: Fire protectice signaling circuits, smoke detectors, audio, control, and initiating circuits.
    • QA (UL) Listed / (UL) FPLR

    FPLR- Fire Alarm Cable
  • Multiconductor- Plenum Rated- Unshielded Cable
    •  FLAME TEST NFPA 262 (Formerly UL 910 Steiner Tunnel)
    •  CABLE TYPE CL3P. Also CMP where UL permits (Sizes 16 AWG and smaller.)
    •  VOLTAGE 300V
    •  TEMPERATURE 75C
    •  SUITABLE USE: General purpose low voltage and power-limited systems' circuits to NEC Article 725 16 AWG and smaller also for communications circuits to NEC Article 800.
    •  QA UL listed to UL 444 and UL 13 as applicable.

    Multiconductor- Plenum Rated- Unshielded Cable
  • Multiconductor- Riser Rated- Unshielded Cable
    •  FLAME TEST UL 1666
    •  CABLE TYPE CL3R. Also CMR where UL permits (Sizes 16 AWG and smaller.)
    •  VOLTAGE 300V
    •  TEMPERATURE 75C
    •  SUITABLE USE: General purpose low voltage and power-limited systems' circuits to NEC Article 725 16 AWG and smaller also for communications circuits to NEC Article 800.
    • QA UL listed to UL 444 and UL 13 as applicable.
    Multiconductor- Riser Rated- Unshielded Cable
  • Multiconductor- Plenum Rated- Shielded Cable
    • FLAME TEST NFPA 262 (Formerly UL 910 Steiner Tunnel)
    • CABLE TYPE CL3P. Also CMP where UL permits (Sizes 16 AWG and smaller.)
    • VOLTAGE 300V
    • TEMPERATURE 75C
    • SUITABLE USE: General purpose low voltage and power-limited systems' circuits to NEC Article 725 16 AWG and smaller also for communications circuits to NEC Article 800.
    • QA UL listed to UL 444 and UL 13 as applicable.

    Multiconductor- Plenum Rated- Shielded Cable
  • Multiconductor- Riser Rated- Shielded Cable
    •  FLAME TEST UL 1666
    •  CABLE TYPE CL3R. Also CMR where UL permits (Sizes 16 AWG and smaller.)
    •  VOLTAGE 300V
    •  TEMPERATURE 75C
    •  SUITABLE USE: General purpose low voltage and power-limited systems' circuits to NEC Article 725 16 AWG and smaller also for communications circuits to NEC Article 800.
    • QA UL listed to UL 444 and UL 13 as applicable.

    Multiconductor- Riser Rated- Shielded Cable
  • Home Automation Combination Cable
    • Available in 1000ft or 500 ft reels.
    • Armor, alternate color codes, and alternate options can be ordered.

    Home Automation Combination Cable
  • Alumaflex™ Type MC XHHW-2
    • UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
    • Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.
    • Anti-short bushings are not required for use with MC cable per the NEC and UL
    Alumaflex™ Type MC XHHW-2
  • AlumaFlex™ Type MC-XHHW-2 PVC Jacketed
    • UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
    • Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.
    • Anti-short bushings are not required for use with MC cable per the NEC and UL
    AlumaFlex™ Type MC-XHHW-2 PVC Jacketed
  • Armorlite ® Type MC - Copper Conductors
    • Copper Power Feeder Conductors.
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • THHN/THWN-2 Insulated Singles.
    • Bare Copper Grounding Conductor.
    • Sizes 1 AWG through 750kcmil.
    Armorlite ® Type MC - Copper Conductors
  • Armorlite ® Type MC - PVC Jacketed - Copper Conductors
    • Copper Power Feeder Conductors.
    • Lightweight Aluminum Interlocked Armor with Overall PVC Jacket.
    • 600 Volts.
    • THHN/THWN-2 Insulated Singles.
    • Bare Copper Grounding Conductor.
    • Sizes 1 AWG through 750 kcmil.
    Armorlite ® Type MC - PVC Jacketed - Copper Conductors
  • AlumaFlex™ Type MC AL THHN/THWN-2 Conductors
    • Type MC - 1/0 AWG through 900 kcmil - with triple e TM Aluminum Alloy Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • AlumaFlex TM with triple e TM Aluminum Alloy 8000 series (AA8176) Conductors.
    • THHN/THWN-2 Insulated Singles.
    • Bare AlumaFlex TM Aluminum Alloy Grounding Conductor
    AlumaFlex™ Type MC AL THHN/THWN-2 Conductors
  • AlumaFlex ™ Type MC Jacketed AL THHN Conductors
    • Type MC PVC Jacketed - 1/0 AWG through 900 kcmil - with triple e TM Aluminum Alloy Lightweight Aluminum Interlocked Armor with Overall PVC Jacket,
    • 600 volts.
    • AlumaFlex TM with triple e TM Aluminum Alloy 8000 series (AA8176) Conductors.
    • THHN/THWN-2 Insulated Singles.
    • Bare Aluminum Grounding Conductor.
    AlumaFlex ™ Type MC Jacketed AL THHN Conductors
  •  Copper Riser MC Cable

    Ideal for use in vertical high rise applications.

    Available with THHN or XHHW conductors

    Available in custom constructions and lengths

    Polymeric binder jacket over conductors provides continuous conductor support

    Available with Southwire pulling heads and on stacked reels

    Compatible with any fittings and clamps rated for use with standard Type MC

    Copper Riser MC Cable
  •  Aluminum Riser MC Cable
    • Lightweight Aluminum Interlocked Armor. 600 Volts.
    • AlumaFlexTM with triple eTM Aluminum Alloy 8000 series
    • (AA8176)Conductors, THHN/THWN-2 Insulated Singles
    • Bare AlumaFlexTM Aluminum Alloy Grounding Conductor
    Aluminum Riser MC Cable
  • American Mustang® SJOOW 105°C- Yellow Jacket

    • UL 62

    • CSA Standard 22.2 No. 49

    • NEC 400

    • NEC 501.140 Class I Division 2

    • Passes CSA FT2 Flame Test

    • MSHA

    • Federal and Military Specification JC-580B

    • RoHS-2 (European Directive 2011/65/EU )

     

    American Mustang® SJOOW 105°C- Yellow Jacket
  • American Mustang® SOOW 105°C- Yellow Jacket

    • UL 62

    • CSA Standard 22.2 No. 49

    • NEC 400

    • NEC 501.140 Class I Division 2

    • Passes CSA FT2 Flame Test

    • MSHA

    • Federal and Military Specification JC-580B

    • RoHS-2 (European Directive 2011/65/EU )

    American Mustang® SOOW 105°C- Yellow Jacket
  • Seoprene ® SJEOOW 105°C- Black Jacket

    • UL 62

    • CSA Standard 22.2 No. 49

    • NEC 400

    • NEC 501.140 Class I Division 2

    • Passes CSA FT2 Flame Test

    • MSHA

    • Federal and Military Specification JC-580B

    • RoHS-2 (European Directive 2011/65/EU )

    Seoprene ® SJEOOW 105°C- Black Jacket
  • Seoprene Plus™ SJEOOW 105°C- Yellow Jacket

    • UL Standard 62

    • CSA Standard C22.2 No. 49

    • Passes CSA FT2 Flame Test

    • NEC Article 400

    • NEC Article 501.140 Class I Div. 2

    • MSHA

    • Federal Spec JC580

    • RoHS-2 (European Directive 2011/65/EU )

    Seoprene Plus™ SJEOOW 105°C- Yellow Jacket
  • Seoprene® SEOOW 105°C- Black Jacket

    • UL 62

    • CSA Standard 22.2 No. 49

    • NEC 400

    • NEC 501.140 Class I Division 2

    • Passes CSA FT2 Flame Test

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

    Seoprene® SEOOW 105°C- Black Jacket
  • Seoprene Plus™ SEOOW 105°C- Yellow Jacket

    • UL Standard 62

    • CSA Standard C22.2 No. 49

    • Passes CSA FT2 Flame Test

    • NEC Article 400

    • NEC Article 501.140 Class I Div. 2

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

    Seoprene Plus™ SEOOW 105°C- Yellow Jacket
  • Royal® Type W

    • UL Listed as Type RHH or RHW-2 and Type W per UL 1650UL

    • CSA Standard 22.2 No. 96

    • NEC Article 400

    • Passes CSA FT1, FT5 Horizontal lame Tests

    • 1/0 and larger reated for CT use

    • ANSI/ICEA S-75-381, NEMA WC58

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

    Royal® Type W
  • Royal® SOOW 90°C- Black Jacket

    • UL 62

    • CSA Standard 22.2 No. 49

    • NEC 400

    • NEC 501.140 Class I Division 2

    • Passes CSA FT2 Flame Test

    • MSHA

    • Federal and Military Specification JC-580B

    • RoHS-2 (European Directive 2011/65/EU )

     

    Royal® SOOW 90°C- Black Jacket
  • Royal® SOOW Cord- Control Black Jacket

    • UL 62

    • CSA Standard 22.2 No. 49

    • NEC 400

    • NEC 501.140 Class I Division 2

    • Passes CSA FT2 Flame Test

    • MSHA

    • Federal and Military Specification JC-580B

    • RoHS-2 (European Directive 2011/65/EU )

    Royal® SOOW Cord- Control Black Jacket
  • Royal® SOOW 90°C- Power Size Non-UL Black Jacket

    • ASTM B3, B174

    • NEC 400

    • MSHA

    • Federal and Military Specification JC-580B

    • RoHS-2 (European Directive 2011/65/EU )

     

    Royal® SOOW 90°C- Power Size Non-UL Black Jacket
  • Royal® SOOW 90°C- Power Size UL Black Jacket
    • • UL 62

      • CSA Standard 22.2 No. 49

      • NEC 400

      • NEC 501.140 Class I Division 2

      • Passes CSA FT2 Flame Test

      • MSHA

      • Federal and Military Specification JC-580B

      • RoHS-2 (European Directive 2011/65/EU )

    Royal® SOOW 90°C- Power Size UL Black Jacket
  • Type SJTOOW - Plastic (PVC)
    • 105°C PVC Cord. 300 Volts. Flexible Copper Conductors.
    • Flexible PVC  Insulation and Jacket.
    • Grey or Yellow Jacket.  Rated -34°C to 105°C. Rated as Hard-Usage Service Cord.
    • Flame Retardant and Meets UL and CSA FT2 Flame Tests.
    • Approved for Outdoor Use. Provides Premium Oil Resistance, Water Resistant, and Flexibility.
    Type SJTOOW - Plastic (PVC)
  • Type STOOW - Plastic (PVC)
    • 105°C PVC Cord. 600 Volts. Flexible Copper Conductors.
    • Flexible PVC Insulation and Jacket.
    • Grey or Yellow Jacket. Rated -34°C to 105°C. Rated as Extra Hard-Usage Service Cord.
    • Flame Retardant and Meets UL and CSA FT2 Flame Tests.
    • Approved for Outdoor Use. Provides Premium Oil Resistance, Water Resistant, and Flexibility.
    Type STOOW - Plastic (PVC)
  • SVT Cord
    • Stranded Copper Conductors.
    • 300 Volts; 60 or 105°C.
    • PVC Jacket
    SVT Cord
  • SPT
    • Rated 300 Volts. Rated 105°C or 60°C.
    • Stranded Copper Conductors.
    • Color Coded PVC Insulation/Jacket.
    SPT
  • Seoprene® SEOOW 105°C- Control Black Jacket

    • UL 62

    • CSA Standard 22.2 No. 49

    • NEC 400

    • NEC 501.140 Class I Division 2

    • Passes CSA FT2 Flame Test

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

    Seoprene® SEOOW 105°C- Control Black Jacket
  • Seoprene® SEOOW 105°C- Power Size UL Black Jacket

    • UL 62

    • CSA Standard 22.2 No. 49

    • NEC 400

    • NEC 501.140 Class I Division 2

    • Passes CSA FT2 Flame Test

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

    Seoprene® SEOOW 105°C- Power Size UL Black Jacket
  • Seoprene® SEOOW 105°C- Power Size Non-UL Black Jacket

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

    Seoprene® SEOOW 105°C- Power Size Non-UL Black Jacket
  • Seoprene Plus™ SEOOW 105°C- Power Size Yellow Jacket

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

    Seoprene Plus™ SEOOW 105°C- Power Size Yellow Jacket
  • TITAN® Type HC
    • Hot/Cold Liquidtight Flexible Metal Conduit
    • UL/CSA Listed
    • Oil-Resistant
    • Sunlight-Resistant
    • Temperature Rated -40°C to +105°C
    TITAN® Type HC
  • Alflex ® - Type RWA
    • Aluminum Flexible Metal Conduit. High Strength Aluminum Alloy Strip
    • 5/16" is UL Recognized Component. UL Listed in sizes 3/8" to 3"
    • 600 Volt
    Alflex ® - Type RWA
  • Galflex ® - Type RWS
    • Steel Flexible Metal Conduit. High Strength Steel Strip.
    • UL Recognized Component in 5/16". UL Listed in 3/8" through 3".
    • CSA Listed for Trade Sizes 5/16" and 3/8" Available Upon Request.
    Galflex ® - Type RWS
  • Alflex ® - Type SWA
    • Aluminum Flexible Metal Conduit
    • High Strength Aluminum Alloy Strip
    • Size 5/16" UL Recognized Component
    • UL Listed in Sizes 3/8" and Larger
    • CSA listed
    Alflex ® - Type SWA
  • Titan2™ - Type UL
    • Liquidtight Flexible Metal Conduit.
    • UL Listed.
    • CSA Listed.
    • Oil-Resistant.
    • Sunlight-Resistant.
    • Temperature Rated -30oC to 80oC.
    Titan2™ - Type UL
  • Titan ® - Type CB
    • Liquidtight Flexible Metal Conduit.
    • Easy to Identify Blue Jacket for Computer Applications.
    • UL/CSA Listed.
    • Oil-Resistant.
    • Sunlight-Resistant.
    • Temperature Rated -30oC to 80oC.
    Titan ® - Type CB
  • Titan ® - Type EF
    • Extra-Flexible Liquidtight Metal Conduit.
    • Steel or Aluminum Constructions.
    • General Purpose Use.
    • Oil-Resistant.
    • Sunlight-Resistant.
    • Temperature Rated -10°C to 60°C.
    Titan ® - Type EF
  • Data-Flex ®
    • Flexible Metal Conduit
    • Crush/corrosion resistant
    • Smooth interior for easy pulling
    Data-Flex ®
  • Slinky-Flex ® - Type SF
    • Extra Flexible Metal Conduit.
    • Allows "U" Bends for Tight Applications.
    Slinky-Flex ® - Type SF
  • Ultratite ® - Type NMHC
    • Hot/Cold Liquidtight Flexible Nonmetallic Conduit.
    • Oil-Resistant.
    • Sunlight-Resistant.
    • Crush-Resistant.
    • UL/CSA Listed.
    • Temperature Rated -40oC to 105oC.
    Ultratite ® - Type NMHC
  • Ultratite ® - Type NMOR
    • Oil Resistant Liquidtight Flexible Nonmetallic Conduit.
    • UL/CSA Listed.
    • Sunlight-Resistant.
    • Crush-Resistant.
    • Temperature Rated -30oC to 80oC.
    Ultratite ® - Type NMOR
  • Ultratite ® - Type NM
    • Liquidtight Flexible Nonmetallic Conduit.
    • UL/CSA Listed
    • Oil resistant 
    • Sunlight-Resistant.
    • Crush-Resistant.
    • Temperature Rated -30oC to 80oC.
    Ultratite ® - Type NM
  • American Mustang ® Orange Welding Cable
    • Premium Grade Orange CPE Jacket. . 
    • Superior Flexibility, Flame Retardant, Oil and Solvents Resistant.
    • Weather and Ozone Resistant.
    • 105°C to -55°C 600 Volt.

    American Mustang ® Orange Welding Cable
  • Red Welding Cable
    • 600 Volts. Rated for -55°C to 105°C. Sizes 6 AWG - 500 MCM.
    • Good Flexibility. Oil Resistant.
    • Resists Compression, Cuts and Abrasion.
    • Red EPDM Jacket, RoHS Compliant.
    Red Welding Cable
  • Black non-UL Welding Cable
    • 600 Volts. Rated for -55°C to 105°C. Sizes 6 AWG - 500 MCM.
    • Good Flexibility. Oil Resistant.
    • Resists Compression, Cuts and Abrasion.
    • Black EPDM Jacket, RoHS Compliant.
    Black non-UL Welding Cable
  • 2KV Diesel Locomotive Cable
    • 2000 V
    • 90°C
    • MSHA Accepted
    • UL Listed as Type RHH/RHW-2
    • CT Rated
    • RoHS Compliant
    2KV Diesel Locomotive Cable
  • Royal® Type W

    • UL Listed as Type RHH or RHW-2 and Type W per UL 1650UL

    • CSA Standard 22.2 No. 96

    • NEC Article 400

    • Passes CSA FT1, FT5 Horizontal lame Tests

    • 1/0 and larger reated for CT use

    • ANSI/ICEA S-75-381, NEMA WC58

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

     

    Royal® Type W
  • Type SC Entertainment Cable
    • Type SC Entertainment Cable. 600 Volts. Extra Flexible Copper Conductors.
    • Water and Sunlight Resistant. Designed to Withstand Severe Environmental Conditions. 
    • 105°C to -40°C. Listed for Indoor or Outdoor Use. Flame Retardant.
    • Provides Flexibility, Resistance to Oil, Solvents, Ozone, Aging, and Abrasion.
    Type SC Entertainment Cable
  • Royal® Bus Drop

    • UL Subject 509

    • RoHS-2 (European Directive 2011/65/EU )

    Royal® Bus Drop
  • Temporary Jumper Cable
    • Single Conductor
    • 4 AWG - 500 kcmil
    • 90°C Damp or Dry Locations
    • 5/15kV EPR Insulation, Non-Shielded
    • Test
    Temporary Jumper Cable
  • Canadian Type G-GC and Type G Round
    • 2000 Volts. 90°C(-40°C). Sunlight and Oil Resistant.
    • UL and c(UL) Listed, MSHA Approved, and RoHS Compliant.
    Canadian Type G-GC and Type G Round
  • Royal® Type G
    • 2000 Volts. 90°C(-40°C). Sunlight and Oil Resistant.
    • UL and c(UL) Listed, MSHA Approved, and RoHS Compliant.
    Royal® Type G
  • Royal® Type G-GC

    • UL Listed as Type G per UL 1650

    • CSA Standard 22.2 No. 96

    • NEC Article 400

    • Passes CSA FT1, FT5 Horizontal lame Tests

    • MSHA

    • RoHS-2 (European Directive 2011/65/EU )

    Royal® Type G-GC
  • Royal <sup>®</sup> Type SOOW
    • 90°C, 600 Volts. Flexible Stranding. Water Resistant 60°C.
    • Black Jacket. Rated -40°C to 90°C. RoHS Compliant.
    • UL Listed and CSA Certified for Indoor and Outdoor Use.
    • 18 AWG - 10 AWG - Multi-conductor Shielded
    Royal ® Type SOOW
  • TelcoSafe® I
    • 600 Volts, Copper Conductor
    • Central Office Power Wire and Cable
    • Flexible Central Office Power Wire and Cable
    • CSA approved, Non-Halogen Insulation
    • 8 AWG thru 750 KCMIL - Single Conductor
    • 90°C Dry, 75°C Wet to -40°C
    TelcoSafe® I
  • TelcoFlex® II
    • 600 Volts, Copper Conductor  
    • Class l Flexible Strand Without Braid
    • CSA Approved, Non-Halogen  Insulation
    • 8 AWG thru 750 KCMIL - Single Conductor
    TelcoFlex® II
  • TelcoFlex® III
    • 600 Volts, Copper Conductor
    • Central Office / Telecom Power Cable
    • Class B Strand With Braid
    • CSA approved, Non-Halogen Insulation
    • 14 AWG - 750 KCMIL - Single Conductor
    TelcoFlex® III
  • TelcoFlex® IV
    • 600 Volts, Copper Conductor  
    • Class l Flexible Strand With Braid
    • CSA approved, Non-Halogen Insulation
    • 8 AWG - 750 KCMIL - Single Conductor
    TelcoFlex® IV
  • Lite-Whip Pre-Assembled  (Steel Flex 6' Fixture Whips)
    • Interlocked Steel Armor with Factory Installed Conductors.
    • Factory Installed Lock-nut or Snap-in Fittings. 600 Volts.
    • Sizes 18 and 16 AWG Copper TFN or TFFN Conductors.
    • Sizes 14 and 12 AWG Copper THHN/THWN Conductors.
    • Green Insulated Copper Grounding Conductor.
    Lite-Whip Pre-Assembled (Steel Flex 6' Fixture Whips)
  • Modular Assemblies
    • 14 AWG through 10 AWG THHN/THWN Insulated Singles
    • Green Insulated Ground
    • UL Listed
    • 600 Volts
    • Rated VW-1
    • Lightweight Aluminum Interlocked Armor
    • Includes UL Listed Fittings and Prepared Cable Ends

     

    Modular Assemblies
  • Ultra-Whip (Non-Metallic Hook-Up Whips)
    • 600 Volt. Stranded Copper THHN/THWN Insulated Singles.
    • Green Insulated Copper Grounding Conductor.
    • Highly Flexible Non-metallic Conduit with Factory Installed Conductors.
    • Liquidtight Flexible Non-metallic Conduit Type B (LFNC-B) Fittings.
    • Intended for 208/240/480 Volt Single Phase Circuits.
    Ultra-Whip (Non-Metallic Hook-Up Whips)
  • AAAC-6201
    • All Aluminum-Alloy Conductor.
    • Bare.
    AAAC-6201
  • AAC
    • All Aluminum Conductor.
    • Bare.
    AAC
  • ACSR
    • Aluminum Conductor.
    • Steel Reinforced.
    • Bare.
    ACSR
  • ACSR/AW
    • Aluminum Conductor.
    • Aluminum-Clad Steel Reinforced.
    • Bare.
    ACSR/AW
  • ACAR
    • Aluminum Conductor.
    • Aluminum Alloy Reinforced.
    • Bare.
    ACAR
  • ACSR/TW
    • Aluminum Conductor.
    • Steel Reinforced.
    • Trapezoidal Shaped Aluminum Strands.
    • Bare.
    ACSR/TW
  • AAC/TW
    • All Aluminum Conductor.
    • Trapezoidal Shaped Conductors.
    • Bare.
    AAC/TW
  • Motion-Resistant Conductor
    • ACSR Motion-Resistant Conductor.
    • Bare Aluminum Conductor, Steel Reinforced.
    Motion-Resistant Conductor
  • VR2 Cable
    • Vibration-Resistant.
    • Bare Aluminum Cable.
    • Available in AAC and ACSR Constructions.
    VR2 Cable
  • ACSS
    • Aluminum Conductor, Steel Supported.
    • Bare
    ACSS
  • ACSS/AW
    • Aluminum Conductor.
    • Aluminum-Clad Steel Supported.
    ACSS/AW
  • ACSS/TW
    • Aluminum Conductor, Steel Supported.
    • Trapezoidal Shaped Aluminum Strands.
    • Bare.
    ACSS/TW
  • Armor Wire/Binder Tape
    • Aluminum Armor Wire and Binder Tape.
    • Rectangular Soft 1350 Aluminum Alloy.
    Armor Wire/Binder Tape
  • Tie & Ground Wire
    • Aluminum Tie and Ground Wire.
    • Solid Soft 1350 Aluminum Alloy.
    Tie & Ground Wire
  • Covered Line Wire
    • Aluminum Conductor.
    • Polyethylene or Crosslinked Polyethylene Covering.
    Covered Line Wire
  • Parallel Aerial Cable
    • Parallel Aerial Cable.
    • Aluminum Conductors.
    • High Density Polyethylene or Crosslinked Polyethylene Insulation.
    Parallel Aerial Cable
  • Reverse Twist Secondary
    • Reverse Twist Secondary.
    • Aluminum Conductors.
    • High Density Polyethylene or Crosslinked Polyethylene Insulation.
    Reverse Twist Secondary
  • Single Conductor 600V
    • Aluminum Conductor.
    • Cross-linked Polyethylene (XLP) Insulation.
    Single Conductor 600V
  • Duplex 600V Secondary UD
    • Aluminum Conductors.
    • Cross-linked Polyethylene (XLP) Insulation.
    Duplex 600V Secondary UD
  • Triplex 600V Secondary UD
    • Aluminum Conductors.
    • Cross-linked Polyethylene (XLP) Insulation.
    Triplex 600V Secondary UD
  • Quadruplex 600V
    • Aluminum Conductors.
    • Cross-linked Polyethylene (XLP) Insulation.
    Quadruplex 600V
  • HI-SCORE Single Conductor 600V
    • Aluminum Conductor.
    • Ruggedized XLP Insulation.
    • Provides Superior Mechanical Protection.
    HI-SCORE Single Conductor 600V
  • HI-SCORE Duplex 600V
    • Aluminum Conductors.
    • Ruggedized XLP Insulation.
    • Provides Superior Mechanical Protection.
    HI-SCORE Duplex 600V
  • HI-SCORE Triplex 600V
    • Aluminum Conductor.
    • Ruggedized XLP Insulation.
    • Provides Superior Mechanical Protection.
    HI-SCORE Triplex 600V
  • HI-SCORE Quadruplex 600V
    • Aluminum Conductors.
    • Ruggedized XLP Insulation.
    • Provides Superior Mechanical Protection.
    HI-SCORE Quadruplex 600V
  • SureSeal® Duplex 600V
    • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
    • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
    • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
    SureSeal® Duplex 600V
  • SureSeal® Triplex 600V
    • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
    • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
    • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
    SureSeal® Triplex 600V
  • SureSeal® Quadruplex 600V
    • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
    • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
    • Sealant also provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
    SureSeal® Quadruplex 600V
  • SureSeal® Single Conductor 600V
    • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
    • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
    • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
    SureSeal® Single Conductor 600V
  • 8000 Series AL Triplex 600V
    • TRIPLE E Aluminum Alloy (AA-8176) Conductors.
    • Cross-linked Polyethylene (XLP) Insulation.
    8000 Series AL Triplex 600V
  • Quadruplex 600V Secondary UD RHH or RHW-2 or USE-2 AlumaFlex®
    • TRIPLE E Aluminum Alloy (AA-8176) Conductors.
    • Cross-Linked Polyethylene (XLP) Insulation.
    Quadruplex 600V Secondary UD RHH or RHW-2 or USE-2 AlumaFlex®
  • PowerGlide Triplex 600V
    • Aluminum conductor
    • Cross-linked polyethylene (XLP) insulation
    • Easy to pull or push
    PowerGlide Triplex 600V
  • PowerGlide Quadruplex 600V
    • Aluminum Conductor
    • Cross-linked Polyethylene (XLP) Insulation
    • Easy to Pull or Push
    PowerGlide Quadruplex 600V
  • PowerGlide HI-SCORE Triplex 600V
    • Aluminum Conductor.
    • Ruggedized Cross-linked Polyethylene (XLP) Insulation.
    • Provides Superior Mechanical Protection.
    • Easy to Pull or Push.
    PowerGlide HI-SCORE Triplex 600V
  • PowerGlide HI-SCORE Quadruplex 600V
    • Aluminum Conductor.
    • Ruggedized Cross-linked Polyethylene (XLP) Insulation.
    • Provides Superior Mechanical Protection.
    • Easy to Pull or Push.
    PowerGlide HI-SCORE Quadruplex 600V
  • 15kV HI-DRI UD
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    15kV HI-DRI UD
  • 25kV HI-DRI UD
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    25kV HI-DRI UD
  • 28kV HI-DRI UD
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    28kV HI-DRI UD
  • 35kV HI-DRI UD
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    35kV HI-DRI UD
  • 15kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Low Density Polyethylene Jacket.
    15kV HI-DRI Jacketed
  • 25kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Low Density Polyethylene Jacket.
    25kV HI-DRI Jacketed
  • 28kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Low Density Polyethylene Jacket.
    28kV HI-DRI Jacketed
  • 35kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Low Density Polyethylene Jacket.
    35kV HI-DRI Jacketed
  • 46kV HI-DRI Jacketed
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Low Density Polyethylene Jacket.
    46kV HI-DRI Jacketed
  • LCT Shielded Primary UD TRXLP Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Copper Longitudinal Corrugated Tape Shield (LCT).
    • Low Density Polyethylene Jacket.
    LCT Shielded Primary UD TRXLP Cable
  • 15kV PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Engineered PowerGlide™ Polyethylene Jacket.
    15kV PowerGlide MV Primary UD Cable
  • 25kV PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Engineered PowerGlide™ Polyethylene Jacket.
    25kV PowerGlide MV Primary UD Cable
  • 28kV PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Engineered PowerGlide™ Polyethylene Jacket.
    28kV PowerGlide MV Primary UD Cable
  • 35kV PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductor.
    • TRXLP Insulation.
    • Bare Copper Concentric Neutrals.
    • Engineered PowerGlide™ Polyethylene Jacket.
    35kV PowerGlide MV Primary UD Cable
  • LCT Shielded PowerGlide MV Primary UD Cable
    • Aluminum or Copper Conductors.
    • TRXLP Insulation.
    • Copper Longitudinal Corrugated Tape Shield (LCT).
    • Engineered PowerGlide™ Polyethylene Jacket.
    LCT Shielded PowerGlide MV Primary UD Cable
  • EPEC-11 CIC SIMpull
    • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
    • EPEC-11 Wall Thicknesses.
    EPEC-11 CIC SIMpull
  • EPEC-13.5 CIC SIMpull
    • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
    • EPEC-13.5 Wall Thicknesses.
    EPEC-13.5 CIC SIMpull
  • EPEC-17 CIC SIMpull
    • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
    • EPEC-17 Wall Thicknesses.
      EPEC-17 CIC SIMpull
    • EPEC-40 CIC SIMpull
      • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
      • EPEC-40 Wall Thicknesses.
      EPEC-40 CIC SIMpull
    • EPEC-80 CIC SIMpull
      • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
      • EPEC-80 Wall Thicknesses.
        EPEC-80 CIC SIMpull
      • SIMpull® Cable-in-Conduit Standard Wall
        • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
        • Standard Wall Thicknesses.
          SIMpull® Cable-in-Conduit Standard Wall
        • HV Cable System Options
          • Feasibility studies and conceptual engineering
          • Detailed underground system design
          • Pulling calculations
          HV Cable System Options
        • 161kV
          • Compressed Round or Compacted Segmental Conductor
          • Corrugated Metallic Sheath or Cu Laminate Sheath
          • True Triple Extrusion
          • Super Clean XLPE Insulation
          161kV
        • 115kV
          • Compressed Round or Compacted Segnental Conductor
          • Corrugated Metallic Sheath or Cu Laminate Sheath
          • True Triple Extrusion
          • Super Clean XLPE Insulation
          • Insulation thickness 550 mils-800 mils
          115kV
        • 69kV
          • Compressed Round or Compacted Segmental Conductor
          • Corrugated Metallic Sheath or Cu Laminate Sheath
          • True Triple Extrusion
          • Super Clean XLPE Insulation
          • Insulation thickness 450 mild-650 mils
          69kV
        • 138kV
          • Compressed Round or Compacted Segmental Conductor
          • Corrugated Metallic Sheath or Cu Laminate Sheath
          • True Triple Extrusion
          • Super Clean XLPE Insulation
          • Insulation thickness 650 mils-850 mils
          138kV
        • 230kV
          • Compressed Round or Compacted Segmental Conductor
          • Corrugated Metallic Sheath or Cu Laminate Sheath
          • True Triple Extrusion
          • Super Clean XLPE Insulation
          • Insulation thickness 850 mils-900 mils
          230kV
        • Outdoor Porcelain Termination
          • Premolded Stress Control System
          • Silicon Fluid Filled
          • Epoxy Standoff Insulators
          • Porcelain Insulator
          • Available from 69kV-230kV
          Outdoor Porcelain Termination
        • Dry Type Plug In Termination
          • Silicone Rubber Stress Cone
          • Plugs into Switchgear Connector
          • Mechanical Screw Top Connector
          • Available up to 145kV
          Dry Type Plug In Termination
        • Epoxy Insulator Termination
          • Silicone Rubber Stress Cone
          • Plugs into Swithgear Connector
          • Mechanical Screw Top Connector
          • Available up to 145kV
          Epoxy Insulator Termination
        • Joint
          • Premolded Joint
          • 3 Piece Design
          • Screw top or Compressed Conductor Connector
          • Compact Dimensions
          • Available from 69kV-230kV
          Joint
        • FEV-V Outdoor Termination with Composite Insulator
          • Premolded Stress Control System
          • Silicon Fluid Filled
          • Epoxy Standoff Insulators
          • Composite Insulator
          • Available from 69kV-230kV
          FEV-V Outdoor Termination with Composite Insulator
        • Aluminum Cable Clamps
          Aluminum Cable Clamps
        • Bonding Cable
          Bonding Cable
        • Link Boxes
          • Stainless steel box
          • Moisture tight and water impervious options available for both outdoor and vault applications
          • Suitable for all voltage classes
          • Zinc oxide sheath voltage limiters
          • Single point, cross-bonding, and direct grounding versions available, with or without removable links
          • Accommodates single core or concentric bonding cables of different diameters
          • 1 phase and 3 phase boxes
          • Different mechanical protection levels up to IP68
          • Short circuit current up to 40 kA for 1 sec
          Link Boxes
        • 5kV Covered Aerial MV Cable - Tree Wire
          • B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
          • B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors.
          • B-232 Concentric-Lay-Stranded, Aluminum Conductors, Coated Steel Reinforced (ACSR).
          • B-498 Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
          • B-399 Standard Specification for Concentric-Lay-Stranded, Aluminum Alloy 6201-T81 Conductors.
          5kV Covered Aerial MV Cable - Tree Wire
        • Multi-Layer 15kV - 46kV Spacer Cable
          • Aluminum Conductor.
          • Track-Resistant HD Polyethylene or Track Resistant Crosslinked polyethylene Covering.
          Multi-Layer 15kV - 46kV Spacer Cable
        • Multi-Layer 15kV - 35kV Tree Wire
          • Aluminum Conductor.
          • Track-Resistant HD Polyethylene or Track-Resistant Crosslinked Polyethylene Covering.
          Multi-Layer 15kV - 35kV Tree Wire
        • Messenger
          • High Strength to Weight
          • Equivalent Conductivity to Bare Aluminum
          • Protects covered conductors from physical damage
          • Superior corrosion resistance
          Messenger
        • 15kV Polymer Insulator
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • Insulator is molded from grey track resistant polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          15kV Polymer Insulator
        • 15kV Polymer Vise-Top Insulator
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • Insulator is molded from grey track resistant polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          • Special clamp with torque colibrated holding bolts
          • Available for both covered and bare conductors
          15kV Polymer Vise-Top Insulator
        • 35kV Polymer Insulator
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • Insulator is molded from a track resistant polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          35kV Polymer Insulator
        • 35kV Polymer Vise-Top Insulator
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • Insulator is molded from grey track resistant polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          • Special clamp with torque calibrated holding bolts
          • Can be easily used in hot stick applications
          • Nylon inserts for covered conductors
          • Metallic inserts for bare conductors
          35kV Polymer Vise-Top Insulator
        • Tie Wire
          • Compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • Compatible with Southwire's and other manufacturers' SCS accessories
          • UV resistant
          • Flexible and easy to install
          • Track resistant
          Tie Wire
        • Torque Bolt
          • Special reduced cross section that is calibrated to provide the optimum clamping force for this cable with break-off eye
          • UV resistant
          • Lightweight and shatter resistant
          Torque Bolt
        • Vise-Top Stringing Tool
          • Stringing Tool molded from a polyurethane compound
          • Lightweight and shatter resistant
          • Designed to be operated either by hot stick or by hand
          • Designed for low friction by hot stick or by hand
          • Designed for low friction with both pulling rope and covered conductors.
          • Easy to install and remove
          Vise-Top Stringing Tool
        • Ring Ties
          • Compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • Ring Ties are molded from a long life track resistant silicone compound
          • UV resistant
          Ring Ties
        • 46kV RatchetLock Spacer
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • RatchetLock Spacer is molded from a track-resistant high-density polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          • Does not require seperate ring ties
          46kV RatchetLock Spacer
        • 35kV Spacer
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • 35kV Spacer is molded from grey high-density track-resistant polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          35kV Spacer
        • 15kV Three Phase Vertical Spacer
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • 15kV 3-Phase Vertical Spacer is molded from grey track-resistant high-density polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          15kV Three Phase Vertical Spacer
        • 15kV Spacer
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • 15kV Spacer is molded from grey high-density track resistant polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          • Can be used on any 5kV - 15kV Covered Aerial MV system
          15kV Spacer
        • 15kV Single Phase Spacer
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • 15kV Single Phase Spacer is molded from grey track-resistant polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          15kV Single Phase Spacer
        • 15kV RatchetLock Spacer
          • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
          • RatchetLock Spacer is molded from grey track-resistant high-density polyethylene compound
          • UV resistant
          • Lightweight and shatter resistant
          • Does not require seperate ring ties
          15kV RatchetLock Spacer
          • Manufactured from high-strength structural steel
          • Corrosion resistant
          • Maintains proper Covered Aerial MV cable orientation
          • Drilled for use on standard utility poles
          "C" Bracket
          • Manufactured from high-strength structural steel
          • Corrosion resistant
          • Maintains proper Covered Aerial MV cable orientation
          • Drilled for use on standard utility poles
          "E" Bracket
        • Anti-sway Bracket
          • Designs that allow flexibility in attachment to the pole
          • Compatible and interchangeable with other manufacturers accessories
          • Lightweight and shatter resistant
          • UV resistant
          Anti-sway Bracket
        • Dead-end Bracket
          • Manufactured from high strength structural steel
          • Corrosion resistant
          • Allows for compact configuration for dead-ending
          • Drilled for use on standard utility poles
          • Uses Standard "C" Bracket and Angle Cross Arm increasing part interchangeability
          Dead-end Bracket
        • Double Insulator Plate
          • Manufactured by casting from ductile iron
          • Corrosion resistant
          • Drilled for 10" insulator spacing
          Double Insulator Plate
        • Messenger Angle Clamps
          • Excellent corrosion resistance
          • Designed to hold up to 14,000 pounds
          • For line angles of up yo 60 degrees
          Messenger Angle Clamps
        • Messenger Clamp
          • Corrosion resistant
          • Designed to allow roll-by installation of Covered Aerial MV cables
          • Will support a wide range of messenger sizes
          Messenger Clamp
        • Tangent
          • Ductile iron construction for higher strength
          • Low profile design without loss of strength
          • Corrosion resistant
          Tangent "L" Bracket
        • Tangent
          • Corrosion resistant
          • Optimally shaped to provide high strength and to maintain optimum cable configuration
          • Enable conductor support at structure and use of anti-sway bracket
          • Attachment hardware provided
          Tangent "L" Bracket Stirrup
        • Transformer Tap Bracket
          • manufactured from-strength structural stell channel
          • Excellent corrosion resistance
          • Provides increased Covered Aerial MV cable spacing to facilitate operations
          Transformer Tap Bracket
        • U-Bolt
          • Excellent corrosion resistance
          • 1 1/2" hole spacing
          • 4 1/2" total length
          • Includes mounting nuts and washers
          U-Bolt
        • Vertical Tap Bracket
          • Manufactured from high-strength structural steel
          • Corrosion resistant
          • Drilled for use on standard utility poles
          • Allows for tap circuit connections with adequate room for connections in minimal space
          Vertical Tap Bracket
        • Messenger Dead-ends
          • Longitudinal Holding Strength equal to messenger UTS
          • Uniform radial pressure exerted on the messenger
          • Designed for specific messenger sizes
          • Color coded for ease of selection in field
          Messenger Dead-ends
        • Aluminum Wedge Dead-end
          • Ease of installation
          • Designed for specific conductor diameters
          • Compatible with all manufacturers’ Covered Aerial MV cable and Tree Wire
          Aluminum Wedge Dead-end
        • Clevises
          • Excellent corrosion resistance
          Clevises
        • Coated Conductor Dead-ends
          • Longitudinal hold strength for spacer cable applications
          • Uniform radial pressure exerted on the conductor cover
          • Designed for specific conductor diameters
          • Color coded for ease of selection in field
          • Coating is compatible with covered conductors
          Coated Conductor Dead-ends
        • Dielectric Wedge Dead-end
          • Ease of installation
          • Designed for specific conductor diameters
          • Compatible with all manufacturers’ Covered Aerial MV cable
          Dielectric Wedge Dead-end
        • Insulator Pins
          • Manufactured from cold rolled steel
          • Corrosion resistant
          • Compatible and interchangeable with Pin Insulators from all manufacturers
          Insulator Pins
        • Messenger Splices
          • Longitudinal holding strength equal to messenger
          • Uniform radial pressure exerted on the messenger
          • Designed for specific messenger sizes
          • Color coded for ease of selection in field
          Messenger Splices
        • Pole Extensions - 30
          • Manufactured from high-strength structural steel
          • Corrosion resistant
          • Drilled for use on standard utility poles
          • Used to provide additional pole height to allow for the installation of additional Covered Aerial MV cable circuit to the pole line
          Pole Extensions - 30"
        • Pole Extensions - >30
          • Manufactured from high-strength structural steel
          • Superior corrosion resistance
          • Pre-drilled for use on standard utility poles
          • Used to provide additional pole height to allow for the installation of Covered Aerial MV circuits to existing pole lines
          • The high-strength variations are available where double circuit or higher circuit loadings need to be acommodated. Two straight structural steel channel sections are used (not shown)
          Pole Extensions - >30"
        • Polymer Dead-end Insulators
          • High strength-to-weight ratio
          • Excellent hydrophobicity
          • Lightweight and shatter resistant
          • Low profile for compact construction
          Polymer Dead-end Insulators
        • Protective Guards
          • UV and track-resistant
          • Lightweight and shatter resistant
          • Incorporates tie hole for securing to messenger
          • Designed for specific messenger sizes
          • Can be cut to lenth in the field
          • Available in black or grey
          Protective Guards
        • Stripping Tool
          • Ease of use
          • Allow for both stripping at the end and mid-span
          • Designed for specific size, diameter and thickness of cables
          Stripping Tool
        • Roll-by Block
          • Swivel between messenger rollers and conductor rollers for better alignment during stringing
          • Non-slip cleat for easy attachment to the tag line
          • Individually guarded rollers to protect covered conductors
          • Available from Southwire with deposit
          Roll-by Block
        • Messenger Trolley and Tag Line
          • Designed for use with Roll-by Block to travel on messenger with pull rope
          • Counterweighted to prevent jumping off of messenger
          Messenger Trolley and Tag Line
        • Stringing Tools
          • Trains cable for ease of installation
          Stringing Tools
        • Splice Cover Kits
          • No torch required
          • Easily installed without any special tools
          • Maintains mechanical and electrical integrity of the cable
          • Compression splices not included
          Splice Cover Kits
        • Proof Positive® Copper
          • For uninsulated hook-ups, jumpers and grounds in substations
          • Unique serial number provides proof of ownership for traceability against theft
          • Available in medium-hard-drawn or annealed tempers
          Proof Positive® Copper
        • Bare Stranded Copper
          • For uninsulated hook-ups, jumpers and grounds in substations
          • Available in hard, medium-hard or soft (annealed) tempers
          Bare Stranded Copper
        • ACSR
          • Aluminum concentrically stranded around steel core
          • Cut to length available
          ACSR
        • AAC
          • Aluminum concentrically stranded
          • Cut to length available
          AAC
        • 1350-O Temper
          • Fully annealed aluminum rope lay stranded
          • Highly flexible
          • Cut to length available
          1350-O Temper
        • Fiber-in-Conduit
          • Fiber cable
          • HDPE conduit
          Fiber-in-Conduit
        • 35kV & 46kV Covered Aerial MV
          • Aluminum conductor
          • PE/XLPE inner covering
          • HDTRPE/XLPE outer covering
          35kV & 46kV Covered Aerial MV
        • Bare Copper
          • For uninsulated hook-ups, jumpers and grounds in substations
          • Available in hard, medium-hard or soft (annealed) temper
          Bare Copper
        • Proof Positive® Copper
          • Copper conductor
          • For uninsulated hook-ups, jumpers and grounds in substations
          • Unique serial number provides proof of ownership for traceability against theft
          • Available in medium-hard-drawn or annealed tempers
          Proof Positive® Copper
        • 2kV Aluminum RHH/RHW-2
          • Aluminum conductor
          • XLPE insulation
          2kV Aluminum RHH/RHW-2
        • 35kV XLPE MV Cables
          • Copper or aluminum conductor
          • XLPE insulation
          • PE jacket
          35kV XLPE MV Cables
        • CT1A-13ET
          • Aluminum conductor
          • EPR insulation
          • Copper tape shield
          • SIMpull® PVC jacket
          CT1A-13ET
        • EFC CT1-13ET
          • Copper conductor
          • EPR insulation
          • Copper tape shield
          • PVC jacket
          EFC CT1-13ET
        • CT1A-09ET
          • Aluminum conductor
          • EPR insulation
          • Copper tape shield
          • SIMpull® PVC jacket
          CT1A-09ET
        • EFC CT1-09ET
          • Copper conductor
          • EPR insulation
          • Copper tape shield
          • PVC jacket
          EFC CT1-09ET
        • RHH/RHW/USE (Copper) 600V
          • Copper conductor
          • XLPE insulation
          RHH/RHW/USE (Copper) 600V
        • RHH/RHW/USE (Aluminum) 600V
          • Aluminum conductor
          • XLPE insulation
          RHH/RHW/USE (Aluminum) 600V
        • Bare Copper
          • For uninsulated hook-ups, jumpers and grounds in substations
          • Available in hard, medium-hard or soft (annealed) temper
          Bare Copper
        • Proof Positive® Copper
          • Copper conductor
          • For uninsulated hook-ups, jumpers and grounds in substations
          • Unique serial number provides proof of ownership for traceability against theft
          • Available in medium-hard-drawn or annealed tempers
          Proof Positive® Copper
        • Fiber-in-Conduit
          • Fiber conductor
          • HDPE conduit
          Fiber-in-Conduit
        • Heliostat Cable: Branch
          • Tin coated copper conductor
          • XHHW insulation (power); XLPE insulation (communication)
          • PVC jacket
          Heliostat Cable: Branch
        • Heliostat Cable: Armored Trunk
          • Tin coated copper conductor
          • XHHW insulation (power); XLPE insulation (communication)
          • Armor-X, aluminum or galvanized steel interlocking armor
          • PVC jacket
          Heliostat Cable: Armored Trunk
        • 35kV & 46kV Covered Aerial MV
          • Aluminum conductor
          • PE/XLPE inner covering
          • HDTRPE/XLPE outer covering
          35kV & 46kV Covered Aerial MV
        • Copper RWU90
          • Copper conductor
          • XLPE insulation
          Copper RWU90
        • Aluminum RWU90
          • Aluminum conductor
          • XLPE insulation
          Aluminum RWU90
        • 25kV MV EPR Cable
          • Copper or aluminum conductor
          • EPR insulation
          • PE jacket
          25kV MV EPR Cable
        • 25kV MV XLPE Cable
          • Copper or aluminum conductor
          • XLPE insulation
          • PE jacket
          25kV MV XLPE Cable
        • HVTC CU 3C 115TRXLPE TS PVC 5KV 133% CSA B44

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 3C 115TRXLPE TS PVC 5KV 133% CSA B44
        •  HVTC AL 3C 90TRXLPE TS PVC 5KV 100% CSA Y75

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 3C 90TRXLPE TS PVC 5KV 100% CSA Y75
        • HVTC AL 3c 90EPR TS PVC 5KV 100% CSA X77

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 3c 90EPR TS PVC 5KV 100% CSA X77
        • HVTC AL 1C 115TRXLPE TS 5KV 133% CSA A99

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 115TRXLPE TS 5KV 133% CSA A99
        • HVTC AL 1C 115EPR TS PVC 5KV 133% CSA E58

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 1C 115EPR TS PVC 5KV 133% CSA E58
        • HVTC AL 1C 90TRXLPE TS PVC 5KV 100% CSA Q55

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 1C 90TRXLPE TS PVC 5KV 100% CSA Q55
        • HVTC AL 1C 90EPR TS PVC 5KV 100% CSA B82

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 90EPR TS PVC 5KV 100% CSA B82
        • HVTC AL 3C 115EPR TS PVC 5KV 133% CSA P26

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 3C 115EPR TS PVC 5KV 133% CSA P26
        • HVTC CU 3C 115EPR TS PVC 5KV 133% CSA W19

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 3C 115EPR TS PVC 5KV 133% CSA W19
        • HVTC CU #C 90EPR TS PVC 5KV 100% CSA U78

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU #C 90EPR TS PVC 5KV 100% CSA U78
        • HVTC CU 3C 90TRXLPE TS PVC 5KV 100% CSA Z75

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 3C 90TRXLPE TS PVC 5KV 100% CSA Z75
        • HVTC CU 1C 115EPR TS PVC 5KV 133%  CSA F39

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 115EPR TS PVC 5KV 133% CSA F39
        • HVTC CU 1C 90TRXLPE TS PVC 5KV 100% CSA M45

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 90TRXLPE TS PVC 5KV 100% CSA M45
        • HVTC CU 1C 90EPR TS PVC 5KV 100% CSA F56

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 1C 90EPR TS PVC 5KV 100% CSA F56
        • HVTC AL 3C 115TRXLPE TS PVC 5KV 133% CSA Z40

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 3C 115TRXLPE TS PVC 5KV 133% CSA Z40
        • CSA HVTC AL 3c 90 EPR 5kV 100% 133%

          CSA HVTC AL 3c 90EPR TS PVC 5KV 100% 133%

          CSA HVTC AL 3c 90 EPR 5kV 100% 133%
        •  HVTC AL 1C 115EPR TS PVC 8KV 100% CSA U38

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 1C 115EPR TS PVC 8KV 100% CSA U38
        •  HVTC AL 1C 115TRXLPE TS PVC 8KV 100% CSA M81

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 115TRXLPE TS PVC 8KV 100% CSA M81
        •  HVTC AL 1C 140EPR TS PVC 8KV 133% CSA D86

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 140EPR TS PVC 8KV 133% CSA D86
        •  HVTC AL 1C 140TRXLPE TS PVC 8KV 133% CSA G80

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 140TRXLPE TS PVC 8KV 133% CSA G80
        •  HVTC AL 3C 115EPR TS PVC 8KV 100% CSA S46

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 3C 115EPR TS PVC 8KV 100% CSA S46
        •  HVTC AL 3C 115TRXLPE TS PVC 8KV 100% CSA J88

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 3C 115TRXLPE TS PVC 8KV 100% CSA J88
        •  HVTC AL 3C 140TRXLPE TS PVC 8KV 133% CSA M60

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 3C 140TRXLPE TS PVC 8KV 133% CSA M60
        •  HVTC CU 1C 115EPR TS PVC 8KV 100% CSA N37

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 1C 115EPR TS PVC 8KV 100% CSA N37
        •  HVTC CU 1C 115TRXLPE TS PVC 8KV 100% CSA V10

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 1C 115TRXLPE TS PVC 8KV 100% CSA V10
        •  HVTC CU 1C 140EPR TS PVC 8KV 133% CSA Q17

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 140EPR TS PVC 8KV 133% CSA Q17
        •  HVTC CU 1C 140TRXLPE TS PVC 8KV 133% CSA V12

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 140TRXLPE TS PVC 8KV 133% CSA V12
        •  HVTC CU 3C 115TRXLPE TS PVC 8KV 100% CSA B03

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 3C 115TRXLPE TS PVC 8KV 100% CSA B03
        •  HVTC CU 3C 140TRXLPE TS PVC 8KV 133% CSA P31

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 3C 140TRXLPE TS PVC 8KV 133% CSA P31
        •  HVTC CU 3C 140EPR TS PVC 8KV 133% CSA W94

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 3C 140EPR TS PVC 8KV 133% CSA W94
        •  HVTC AL 3C 140EPR TS PVC 8KV 133% CSA S85

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 3C 140EPR TS PVC 8KV 133% CSA S85
        •  HVTC CU 3C 220TRXLPE TS PVC 15KV 133% CSA U33

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 3C 220TRXLPE TS PVC 15KV 133% CSA U33
        •  HVTC CU 3C 220EPR TS PVC 15KV 133% CSA F70

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 3C 220EPR TS PVC 15KV 133% CSA F70
        •  HVTC CU 3C 175TRXLPE TS PVC 15KV 100% CSA V96

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 3C 175TRXLPE TS PVC 15KV 100% CSA V96
        •  HVTC CU 3C 175EPR TS PVC 15KV 100% CSA C45

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 3C 175EPR TS PVC 15KV 100% CSA C45
        •  HVTC CU 1C 220TRXLPE TS PVC 15KV 133% CSA N95

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 1C 220TRXLPE TS PVC 15KV 133% CSA N95
        •  HVTC CU 1C 220EPR TS PVC 15KV 133% CSA R77

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 1C 220EPR TS PVC 15KV 133% CSA R77
        •  HVTC CU 1C 175TRXLPE TS PVC 15KV 100% CSA M34

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 175TRXLPE TS PVC 15KV 100% CSA M34
        •  HVTC CU 1C 175EPR TS PVC 15KV 100% CSA M93

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 175EPR TS PVC 15KV 100% CSA M93
        •  HVTC AL 3C 220TRXLPE TS PVC 15KV 133% CSA J40

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 3C 220TRXLPE TS PVC 15KV 133% CSA J40
        •  HVTC AL 3C 220EPR TS PVC 15KV 133% CSA Q50

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 3C 220EPR TS PVC 15KV 133% CSA Q50
        •  HVTC AL 3C 175TRXLPE TS PVC 15KV 100% CSA B95

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 3C 175TRXLPE TS PVC 15KV 100% CSA B95
        •  HVTC AL 3C 175EPR TS PVC 15KV 100% CSA Z95

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 3C 175EPR TS PVC 15KV 100% CSA Z95
        •  HVTC AL 1C 220TRXLPE TS PVC 15KV 133% CSA X83

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 1C 220TRXLPE TS PVC 15KV 133% CSA X83
        •  HVTC AL 1C 220EPR TS PVC 15KV 133% CSA H69

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 220EPR TS PVC 15KV 133% CSA H69
        •  HVTC AL 1C 175TRXLPE TS PVC 15KV 100% CSA S24

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 1C 175TRXLPE TS PVC 15KV 100% CSA S24
        •  HVTC AL 1C 175EPR TS PVC 15KV 100% CSA P56

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 175EPR TS PVC 15KV 100% CSA P56
        • HVTC AL 1C 260EPR TS PVC 25KV 100% CSA J77

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 1C 260EPR TS PVC 25KV 100% CSA J77
        • HVTC AL 1C 320EPR TS PVC 25KV 133% CSA B79

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 320EPR TS PVC 25KV 133% CSA B79
        • HVTC AL 1C 260TRXLPE TS PVC 25KV 100% CSA V13

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 260TRXLPE TS PVC 25KV 100% CSA V13
        • HVTC AL 1C 320TRXLPE TS PVC 25KV 133% CSA E40

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 1C 320TRXLPE TS PVC 25KV 133% CSA E40
        • HVTC AL 3C 260EPR TS PVC 25KV 100% CSA K40

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 3C 260EPR TS PVC 25KV 100% CSA K40
        • HVTC AL 3C 260TRXLPE TS PVC 25KV 100% CSA D31

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 3C 260TRXLPE TS PVC 25KV 100% CSA D31
        • HVTC AL 3C 320EPR TS PVC 25KV 133% CSA M37

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 3C 320EPR TS PVC 25KV 133% CSA M37
        • HVTC AL 3C 320TRXLPE TS PVC 25KV 133% CSA L02

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC AL 3C 320TRXLPE TS PVC 25KV 133% CSA L02
        • HVTC CU 1C 260EPR TS PVC 25KV 100% CSA N03

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 260EPR TS PVC 25KV 100% CSA N03
        • HVTC CU 1C 260TRXLPE TS PVC 25KV 100% CSA F02

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 1C 260TRXLPE TS PVC 25KV 100% CSA F02
        • HVTC CU 1C 320EPR TS PVC 25KV 133% CSA G97

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 320EPR TS PVC 25KV 133% CSA G97
        • HVTC CU 1C 320TRXLPE TS PVC 25KV 133% CSA C81

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 1C 320TRXLPE TS PVC 25KV 133% CSA C81
        • HVTC CU 3C 260EPR TS PVC 25KV 100% CSA C06

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 3C 260EPR TS PVC 25KV 100% CSA C06
        • HVTC CU 3C 260TRXLPE TS PVC 25KV 100% CSA N80

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 3C 260TRXLPE TS PVC 25KV 100% CSA N80
        • HVTC CU 3C 320EPR TS PVC 25KV 133% CSA U11

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating

          Designed for harsh Canadian environments

          HVTC CU 3C 320EPR TS PVC 25KV 133% CSA U11
        • HVTC CU 3C 320TRXLPE TS PVC 25KV 133% CSA Y19

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC CU 3C 320TRXLPE TS PVC 25KV 133% CSA Y19
        • HVTC AL 1C 280EPR TS PVC 28KV 100% CSA U49

          CSA Approvals

          • TC-ER – Tray Cable – Exposed Run rating
          • C22.2 No. 230 – Tray Cable Standard
          • C68.10 MV Shielded Power Cable Standard
          • SUN RES. - Sunlight Resistant
          • FT4 Flame Test
          • -40ºC low temperature rating
          • +105ºC high temperature rating
          Designed for harsh Canadian environments

          HVTC AL 1C 280EPR TS PVC 28KV 100% CSA U49
        • HVTC AL 1C 280TRXLPE TS PVC 28KV 100% CSA V34