Conductor,copper,insulation,volt,jcket,aluminum,armor,wire,cable,cord,southwireProduct CatalogProductCatalog.htm
ENU
Register Now Forgot Password?

Southwire Product Catalog

 
Total number of results: 35

Our Product Catalog Download requires WinZip file archiving software. Download Winzip

Click here to show/hide usage instructions.
  • Product group offerings are viewed by clicking on the product group description or on the plus symbol next to the folder icon. This will expand and collapse the product group.
  • A product quick view is obtained by hovering over the product item image. This will display product summary information.
  • A complete product page is viewed by clicking on the product item in the expanded list. This will open the catalog page in a PDF file format.
  • To download multiple pages, click on the box in front of the product pages or groups and then click on "Download Products" found at the top and bottom of the product listing. The selected pages will be downloaded as a zipped file to your computer.
  • To narrow product groups, select a filter from the dropdown listbox.
  • XHHW Aluminum
    • 600 Volt. AlumaFlex® Aluminum Alloy (AA-8176) Conductor.
    • Cross-linked Polyethylene (XLP) Insulation.
    • High-Heat and Moisture Resistant.
    • Sunlight Resistant in Black Sizes 2 AWG and Larger.
    XHHW Aluminum
  • AL-RHH or RHW or USE
    • Underground Service Entrance Cable. 600 Volt.
    • AlumaFlex® Aluminum Alloy (AA-8176) Conductor.
    • Cross-linked Polyethylene(XLP) Insulation.
    • High-Heat, Moisture, and Sunlight Resistant.
    • Rated SIS in #8 - 4/0 AWG.
    AL-RHH or RHW or USE
  • Mobile Home Feeder
    • Underground Service Entrance Cable
    • 600 Volt
    • AlumaFlex® Aluminum Alloy (AA-8176) Conductors
    • Cross-linked Polyethylene (XLP) Insulation
    • Sunlight Resistant
    Mobile Home Feeder
  • Aluminum SE Cable
    • Type SE, Style SER and SEU Service Entrance Cable
    • 600 Volt. AlumaFlex® Aluminum Alloy (AA-8176) Conductors
    • Individual Conductors Rated XHHW or THHN/THWN
    • Jacket and Inner Conductors are Sunlight Resistant
    Aluminum SE Cable
  • SIMpull THHN® Cable with AlumaFlex® Conductors
    • 600 Volts
    • AlumaFlex® Aluminum (AA-8176) Conductor
    • Thermoplastic Insulation / SIM Nylon Sheath
    • Heat, Moisture, Gasoline, and Oil Resistant II, Sunlight Resistant
    • Also Rated THWN-2
    • SIM Technology® for Easier Pulling
    SIMpull THHN® Cable with AlumaFlex® Conductors
  • Primary Wire SXL
    • Stranded bare or copper conductors
    • PVC Insulation.
    • 125°C, 60 Volts.
    Primary Wire SXL
  • GXL
    • Stranded bare or copper conductors
    • PVC insulation
    • 125°C, 60 Volts
    GXL
  • Primary Wire GPT
    • Stranded bare or copper conductors
    • Premium PVC Insulation.
    • 85°C, 60 Volts.
    Primary Wire GPT
  • SGT/SGR/SGX Battery Cable
    • Stranded bare copper with PVC, Rubber, TPR or Cross-Link Insulation.
    • 85°C (SGT), 90°C (SGR), 125°C (SGX). 60 Volts.
    SGT/SGR/SGX Battery Cable
  • Brake Cable
    • Stranded Bare or Tinned Copper Conductors.
    • 85°C and 105°C, 50 Volts.
    Brake Cable
  • Booster Cable
    • Stranded bare copper with PVC and TPE Insulation
    • 85°C and 105°C, 50 Volts
    Booster Cable
  • Trailer Cable
    • Stranded bare copper conductors with PVC,
    • Rubber or TPR insulation;
    • twisted with overall jacket.
    • 60°C, 90°C, 105°C;-40°C, -65°C.
    Trailer Cable
  • Armorlite® Type MC PVC Jacketed Neutral Per Phase

    A dedicated neutral conductor for each phase conductor for compliance with NEC 210.7.
    Reduces installation costs up to 50% over pipe and wire.
    UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121,W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
    Anti-short bushings are not required for use with MC cable per the NEC and UL

    Armorlite® Type MC PVC Jacketed Neutral Per Phase
  • Armorlite® Type MC Neutral Per Phase
    • Lightweight Aluminum Interlocked Armor. 600 Volts.
    • Copper Power Conductors.THHN/THWN Insulated Singles.
    • Dedicated Neutral Conductor for Each Phase Conductor.
    • Insulated GroundingConductors.
    • Sizes 14 AWG and 8 AWG. RatedVW-1.
    Armorlite® Type MC Neutral Per Phase
  • Armorlite® Type MCAP Multi-Circuit

    Reduces installation costs up to 50% over pipe and wire.
    Lightweight aluminum armor--as much as 45% lighter than steel MC Cable.
    UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
    Anti-short bushings are not required for use with MC cable per the NEC and UL

    Armorlite® Type MCAP Multi-Circuit
  • Armorlite ® Type MC
    • Lightweight Aluminum Interlocked Armor. 600 Volts
    • Copper Power Conductors. THHN/THWN Insulated Singles
    • Green Insulated Grounding Conductor
    • Sizes 14 AWG through 2 AWG. Rated VW-1
    Armorlite ® Type MC
  • Armorlite ® Type MC - Isolated Ground
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • Copper Power Conductors.
    • THHN/THWN Insulated Singles.
    • Two Insulated Grounding Conductors.
    • Sizes 12 AWG and 10 AWG.
    • Rated VW-1.
    Armorlite ® Type MC - Isolated Ground
  • Armorlite ® Type MC - Oversized Neutral
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • Copper Power Conductors.
    • THHN/THWN Insulated Singles.
    • Oversized Neutral Conductor.
    • Green Insulated Grounding Conductor.
    • Sizes 12 AWG and 10 AWG.
    • Rated VW-1.
    Armorlite ® Type MC - Oversized Neutral
  • Armorlite ® Type MC - Multi-Circuit
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • Copper Power Conductors.
    • THHN/THWN Insulated Singles.
    • Multiple Circuits.
    • Green Insulated Grounding Conductor.
    • Sizes 12 AWG and 10 AWG.
    • Rated VW-1.
    Armorlite ® Type MC - Multi-Circuit
  • Armorlite ® Type MC - PVC Jacketed
    • Lightweight Aluminum Interlocked Armor with Overall PVC Jacket.
    • 600 Volts.
    • Copper Power Conductors.
    • THHN/THWN Insulated Singles.
    • Sunlight Resistant.
    • Green Insulated Grounding Conductor.
    • Sizes AWG 14 through AWG 2. Rated VW-1.
    Armorlite ® Type MC - PVC Jacketed
  • Armorlite Type MC Quick-Pre-cut Lengths
    • Lightweight Aluminum Interlocked armor.
    • 600 Volts.
    • Solid Copper THHN/THWN Insulated Singles.
    • Green Insulated Copper Grounding Conductor.
    • Cut to Length Type MC Cable with Factory Installed Zinc-Die Cast Snap-in Fittings.
    • 8" Conductor Leads with 1/2" Insulation Stripped, Size 12 AWG.
    Armorlite Type MC Quick-Pre-cut Lengths
  • Armorlite ® Type AC
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts.
    • Copper Power Conductors.
    • Type ACTHH (THHN Singles).
    • 16 AWG Aluminum Bond Wire.
    • Sizes 14 AWG through 2 AWG.
    Armorlite ® Type AC
  • Duraclad® Type AC

    An armor assembly (combination of the interlocked armor & bonding strip) that is recognized as an equipment grounding/bonding conductor per NEC 250.118(8).
    Reduces installation costs up to 50% over pipe and wire.
    Anti-short/insulating bushings supplied with every reel or coil.
    Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.

    Duraclad® Type AC
  • Duraclad® Type AC-HCF Steel Armor Health Care Facility
    • An armor assembly (combination of the interlocked armor & bonding strip) that is recognized as an equipment grounding conductor per the NEC 250.118(8) and 517.13(A).
    • An insulated equipment grounding conductor sized per NEC 517.13(B) and Table 250.122.
    • Reduces installation costs up to 50% over pipe and wire.
    • Anti-short/insulating bushings supplied with every reel or coil.
    Duraclad® Type AC-HCF Steel Armor Health Care Facility
  • Duraclad HCF MC AP Type MC All Purpose Health Care Facility

    Meets UL Product Category PJAZ (Metal-Clad Cable) and provides redundant equipment grounding conductors (as defined in NEC® 250.118) as required in NEC® 517.13(A) & (B).
    Installation instructions included with every reel and coil.
    Simplified armored product application and installation.
    Reduces installation costs up to 50% over pipe and wire.
    Increased labor savings compared to Type AC HCF.
    Easy to identify green armor.

    Duraclad HCF MC AP Type MC All Purpose Health Care Facility
  • Duraclad® MC-PCS Duo™

    MC-PCS Du o™ Cable is constructed with 12 AWG or 10 AWG CU Type THHN/THWN power and ground conductors along with a control conductor assembly composed of a 30 mil PVC jacket covering two 16 AWG CU Type TFN control conductors. The phase conductors, ground,

    Duraclad® MC-PCS Duo™
  • Duraclad ® Type BAG Bare Armored Ground Cable
    • Steel Interlocked Armor.
    • Bare Copper Ground.
    Duraclad ® Type BAG Bare Armored Ground Cable
  • Duraclad Type MC - Lightweight Steel Armor
    • Lightweight Steel Interlocked Armor. 600 Volts
    • Also available in Blue Steel Armor
    • Copper Power Conductors. THHN/THWN Insulated Singles
    • Green Insulated Grounding Conductor
    • Sizes 14 AWG through 10 AWG. Rated VW-1
    Duraclad Type MC - Lightweight Steel Armor
  • HCF MCAP Type MC All Purpose Hospital Care Facility
    • Green Lightweight Aluminum Interlocked Armor.
    • 600 Volt.
    • Copper THHN Insulated Conductors and Green Insulated Ground Conductor.
    • Full-Sized Aluminum Equipment Grounding/Bonding Conductor.
    • Sizes 12 AWG through 10 AWG.
    • UL Listed. Rated VW-1
    HCF MCAP Type MC All Purpose Hospital Care Facility
  • MC-PCS Duo™ PVC Jacketed Power & Control/Signal Cable

    Full compliance with NEC 330, NEC 725, and UL 1569
    16 AWG signal wiring for 0-10V dimming.
    Available in 250’ coils or 1000’ reels
    Available with steel armor
    UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L- 3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065,C-AJ- 4066, F-C-3038.
    Anti-short bushings are not required for use with Type MC Cable per the NEC and UL.

    MC-PCS Duo™ PVC Jacketed Power & Control/Signal Cable
  • MC-PCS Duo™ Power & Control / Signal Cable
    • Lightweight Aluminum Interlocked Armor.
    • 600 Volts. Copper Power & Control Conductors.
    • THHN/THWN & TFN Insulated Singles.
    • Green Insulated Grounding Conductor.
    • Power: 12 AWG & 10 AWG.
    • Control: 16 AWG.
    • Rated FT4/IEEE 1202. Rated 90°C Dry Locations.

    For more information, visit http://mcpcsduo.southwire.com/.

    MC-PCS Duo™ Power & Control / Signal Cable
  • MC-PCS HCF Duo™ Power & Control/Signal Cable for Healthcare Facilities

    Full compliance with NEC 330, NEC 725, and UL 1569
    Meets UL Product Category PJAZ (Metal-Clad Cable) and provides redundant equipment grounding conductors (as
    defined in NEC® 250.118) as required in NEC® 517.13(A) & (B).
    Installation instructions included with every reel and coil
    Circuit identification printed directly on the armor
    Armor ground path is approximately 3.5 times better than Type AC HCF Cable and is equivalent to a green insulated copper grounding conductor.

    MC-PCS HCF Duo™ Power & Control/Signal Cable for Healthcare Facilities
  • MCAP Type MC All Purpose
    • Lightweight Aluminum Interlocked Armor. 600 Volt. Copper THHN Insulated Conductors
    • Full-Sized Aluminum Equipment Grounding/Bonding Conductor. UL Listed. Rated VW-1
    MCAP Type MC All Purpose
  • Multi Circuit MC PVC JKT

    Reduces installation costs up to 50% over pipe and wire.
    UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160,C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038 Anti-short bushings are not required for use with MC cable per the NEC and UL
    Multi Circuit MC PVC JKT
  • PVC Jacketed MCAP HCF ALUMINUM ARMOR
    • 14 AWG through 8 AWG Copper THHN Insulated Conductors and Green Insulated Ground Conductor.
    • Full-Sized Aluminum Equipment Grounding/Bonding Conductor.
    • UL Listed.
    • 600 Volts.
    • Rated VW-1.
    • Green Lightweight Aluminum Interlocked Armor is Part of Equipment Bonding/Grounding Path.
    • Sunlight Resistant, Direct Burial Overall PVC Jacket.

     

    PVC Jacketed MCAP HCF ALUMINUM ARMOR
  • Red Alert ® Type MC - Fire Alarm and Control
    • Red Lightweight Aluminum Interlocked Armor.
    • 600 Volt Type MC and 300 Volt Type FPLP.
    • Plenum Rated.
    • Solid Copper Conductors.
    • Sizes 14 & 12 AWG Type THHN/THWN VW-1 Singles.
    • Sizes 18 &16 AWG Type TFN VW-1 Singles.
    • Green Insulated or Tinned Copper Grounding Conductor.
    • 6/C and 8/C constructions are NOT Plenum Rated.
    Red Alert ® Type MC - Fire Alarm and Control
  • AC90 Copper
    • Copper Conductors
    • 14 to 6 AWG, 600 Volts
    • 90°C
    AC90 Copper
  • AC90 ISO-BX Copper
    • Copper Conductors, PVC/Nylon Insulation
    • 14 to 10 AWG, 600 Volts
    • 90°C; -40°C
    AC90 ISO-BX Copper
  • AL-RW90
    • Single Aluminum Conductor.
    • 600 Volts.
    • 90°C Max, -40°C Min.
    • Sizes 6 and Larger Black is Sunlight Resistant.
    AL-RW90
  • Annunciator (Bell) Wire
    • Soft bare copper conductors, thermoplastic insulation.
    • Multiple conductors are twisted.
    • 105°C, 30 Volts.
    Annunciator (Bell) Wire
  • Battery Cable
    • Stranded bare copper with PVC, Rubber, TPR or Cross-link Insulation
    • 85°C, 90°C, 125°C. 50 Volts
    • RoHS
    Battery Cable
  • Blasting Cable
    • Stranded Copper Conductors
    • Neoprene rubber insulation. 60°C
    • RoHS
    Blasting Cable
  • Booster Cable (Twin)
    • Stranded bare copper with PVC, rubber or TPR insulation
    • 90°C, 50 Volts RoHS
    Booster Cable (Twin)
  • Brake Cable
    • Stranded bare or tinned copper conductors.
    • 105°C, 50 Volts.
    Brake Cable
  • CL 1251/AWM 3173
    • Solid or Stranded Soft Bare or Tinned Copper Conductor. XLPE insulation
    • 125°C Normal Operating Temperature. 600 Volts
    • RoHS
    CL 1251/AWM 3173
  • CSA Teck90 Control Cable
    • 1000 V Multiconductor, Teck 90 Cable
    • 14-10 AWG, XLP insulation
    • Aluminum Interlocked Armor
    • Inner and Outer PVC jackets
    • Rated HL (Hazardous Locations)
    CSA Teck90 Control Cable
  • CSA Teck90 Power Cable
    • 1000 V Multiconductor, Teck 90 Cable
    • 8 and larger AWG, XLP insulation
    • Aluminum Interlocked Armor
    • Inner and Outer PVC jackets
    • Rated HL (Hazardous Locations)
    • 600V UL Type MC
    CSA Teck90 Power Cable
  • CU-NMWU
    • Underground Feeder and Branch Circuit Cable.
    • 300 Volts. Copper Conductors.
    CU-NMWU
  • FAS
    • Solid or stranded bare copper conductors
    • PVC Insulation 105°C, 300 Volts
    • RoHS
    FAS
  • HDT/GPT/TWP
    • Stranded bare or copper conductors
    • PVC Insulation 85°C, 50 Volts
    • RoHS
    HDT/GPT/TWP
  • HPN
    • Bare copper conductors,
    • 2 or 3 conductors laid parallel.
    • 90°C, 300 Volts.
    HPN
  • HSJO/SJOW
    • Bare copper conductors;
    • 60 or 90°C, 300 Volts.
    HSJO/SJOW
  • Irrigation Cable
    • Solid bare copper; PVC insulation; twisted without fillers;overall PVC jacket.
    • 60°C, 30 Volts.
    Irrigation Cable
  • LVT
    • Solid or stranded soft bare copper conductors.
    • 105°C, 300 Volts.
    LVT
  • PXT / PXWT / XTW
    • Bare stranded copper, laid parallel with PVC insulation.
    • 60°C, 125 Volts - PXT 300 Volts - PXWT -34°C)
    PXT / PXWT / XTW
  • Romex® SIMpull® NMD90 Copper
    • Non-metallic Sheathed Cable
    • 300 Volts
    • Copper Conductors
    • SIM Jacket™
    Romex® SIMpull® NMD90 Copper
  • RWU
    • Single Aluminum Conductor.
    • 8 and larger AWG, 1000 Volts.
    • 90°C Max, - 40°C Min.
    RWU
  • RWU90 Copper
    • Single Copper Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant (In Black)
    RWU90 Copper
  • SIMpull® RW90 Copper
    • Single Copper Conductors
    • XLPE Insulation
    • 600 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant
    SIMpull® RW90 Copper
  • SIMpull® RWU90 Copper
    • Single Copper Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant
    SIMpull® RWU90 Copper
  • SIMpull® RWU90 ALUMINUM
    • Aluminum Conductors
    • XLPE Insulation
    • 1000 Volts / -40ºC Min, 90ºC Max
    • Sunlight Resistant
    SIMpull® RWU90 ALUMINUM
  • SIMpull T90
    • 600 Volts. Copper Conductor. Thermoplastic-Insulated/SIM Nylon Sheath
    • Heat, Moisture, Gasoline, and Oil Resistant 1 Rated MTW and THWN
    • Black Sizes Listed Sunlight Resistant for UL appplications
    • SIM Technology® for easier pulling
    SIMpull T90
  • SIMpull® T90 ALUMINUM
    • 600 Volts
    • Aluminum Conductor
    • PVC Insulation
    • All Sizes Rated TWN75
    SIMpull® T90 ALUMINUM
  • SIMpull T90 Nylon
    • 600 Volts.
    • Copper Conductor.
    • Thermoplastic-Insulated Cable.
    • All Sizes rated TWN75.
    • Gasoline and oil resistant.
    SIMpull T90 Nylon
  • SIS
    • Bare or tinned solid or stranded copper.
    • 90°C, 600 Volts.
    SIS
  • Speaker Cable
    • Bare or tinned stranded copper
    • Parallel clear or opaque PVC Insulation.
    • Two Copper Conductors.
    Speaker Cable
  • SPT-1, SPT-2, SPT-3
    • Rated 300 Volts. Rated 105°C
    • Stranded Copper Conductors
    • Thermoplastic Insulation
    • RoHS
    SPT-1, SPT-2, SPT-3
  • STW
    • Bare copper conductors
    • Thermoplastic insulation
    • 60 or 105°C for ST, -34°C for STW
    • 600 Volts
    STW
  • Submersible Pump Cable
    • Solid or stranded bare copper conductors;
    • individuals PVC insulation;
    • 3 or 4 twisted conductors
    • 600 Volts, -40°C.,
    • Maximum 60°C.
    Submersible Pump Cable
  • SXL/GXL/TXL
    • Stranded bare or tinned copper conductors with cross-linked polyethylene insulation.
    • 125°C, 50 Volts.
    SXL/GXL/TXL
  • TEW/AWM 1015/1019/1020/1230 MTW
    • Solid or stranded bare, tinned, or prefused copper
    • Thermoplastic Insulation, 105°C, 600 Volts
    • RoHS
    TEW/AWM 1015/1019/1020/1230 MTW
  • TR32 AWM Style 1013
    • Solid or stranded tinned copper conductors;
    • PVC insulation.
    • 90°C, 600 Volts.
    TR32 AWM Style 1013
  • TR64 AWM 1007
    • Solid or stranded tinned copper conductors
    • PVC insulation. 90°C, 300 Volts.
    • RoHS
    TR64 AWM 1007
  • Trailer Cable
    • Stranded bare copper conductors with PVC,
    • Rubber or TPR insulation; twisted with overall jacket.
    •  60°C, 90°C, 105°C;-40°C, -65°C.
    • RoHS
    Trailer Cable
  • TW75 Copper
    • Copper Conductors
    • 600 Volts
    • Thermoplastic Sunlight Resistant Insulation
    • All Sizes Rated TW75
    TW75 Copper
  • SIMpull® THHN Copper Wire & Cable
    •  600 Volts. Copper Conductor. 
    •  Thermoplastic Insulation/ Nylon Sheath.
    •  Heat, Moisture, Gasoline, and Oil Resistant II.
    • All Sizes Rated Both THHN and either THWN (sizes 14, 12, and 10 AWG) or THWN-2 (sizes 8 AWG and larger).
    • Also Rated MTW and AWM.
    • SIMpull® Technology for Easier Pulling.
    SIMpull® THHN Copper Wire & Cable
  • SIMpull CU-XHHW™
    • 600 Volt
    • Copper conductor
    • Cross-linked polyethylene (XLP) insulation
    • High-heat and moisture resistant
    • SIM Technology® for easier pulling
    • Sizes 14 through 10 AWG also rated SIS
    SIMpull CU-XHHW™
  • CU-RHH or RHW or USE
    • Underground Service Entrance Cable
    • 600 Volt
    • Copper conductors
    • Cross-linked polyethylene (XLP) insulation
    • High-heat, moisture, and sunlight resistant
    • Sizes 6 through 4/0 AWG also rated SIS
    CU-RHH or RHW or USE
  • CU-TFFN
    • 600 Volt.
    • Copper Conductor.
    • Thermoplastic Insulation/Nylon Sheath.
    • Heat, Moisture, Oil, and Gasoline Resistant 1.
    • Also Rated MTW and 105 °C AWM
    • Also Available, TFN and TEWN.
    CU-TFFN
  • Romex® SIMpull® Type NM-B
    • Type NM-B Nonmetallic-Sheathed Cable
    • 600 Volt
    • Copper Conductors
    • Color-coded jacket
    • Four conductor available with two neutrals
    • SIM jacket® designed for easier pulling
    Romex® SIMpull® Type NM-B
  • CU-UF-B
    • Underground Feeder and Branch Circuit Cable
    • 600 Volt
    • Copper conductors
    • Sunlight, moisture, and fungus resistant
    • Overall PVC jacket.
    CU-UF-B
  • Copper SE Cable
    • Service Entrance Cable
    • Type SE, Style SER and SE Stype U
    • Service entrance cable
    • 600 Volt
    • Individual conductors rated XHHW-2 or THHN/THWN
    • Jacket and individual conductors
    • Sunlight resistant
    Copper SE Cable
  • 31UR Multiconductor Non-Shielded Construction Grade Riser Rated
    • Solid or Stranded Bare Copper Conductors; 22AWG through 12 AWG
    • Color Coded PVC or Polypropylene insulation
    • Unshielded
    • Ripcord included for simple jacket tear-back & removal.
    • PVC Jacket. (Gray is standard. Other colors available.)
    31UR Multiconductor Non-Shielded Construction Grade Riser Rated
  • 31UP Multiconductor Non-Shielded Construction Grade Plenum Rated
    • Solid or Stranded Bare Copper Conductors; 22AWG through 12 AWG
    • Color Coded Low Smoke PVC insulation (LS-PVC)
    • Unshielded
    • Ripcord included for simple jacket tear-back & removal.
    • Low Smoke PVC Jacket. (LS-PVC) (White is standard. Other colors available.)
    31UP Multiconductor Non-Shielded Construction Grade Plenum Rated
  • 31SR Multiconductor Shielded Construction Grade Riser Rated
    • Solid or Stranded Bare Copper Conductors; 22AWG through 12 AWG
    • Color Coded Low Smoke PVC insulation (LS-PVC)
    • Unshielded
    • Ripcord included for simple jacket tear-back & removal.
    • Low Smoke PVC Jacket. (LS-PVC) (White is standard. Other colors available.)
    31SR Multiconductor Shielded Construction Grade Riser Rated
  • 31SP Multiconductor Shielded Construction Grade Plenum Rated
    • Solid or Stranded Bare Copper Conductors; 22AWG through 12 AWG
    • Color Coded Low Smoke PVC insulation (LS-PVC)
    • Shielded: Overall aluminum-polyester shielding tape plus tinned copper drain wire.
    • Ripcord included for simple jacket tear-back & removal.
    • Low Smoke PVC Jacket. (LS-PVC) (White is standard. Other colors available.)
    31SP Multiconductor Shielded Construction Grade Plenum Rated
  • 35MR 1PR Shielded plus #/C Unshielded; Construction Grade Riser Rated
    • Solid or Stranded Bare Copper Conductors
    • Color Coded PVC or Polypropylene insulation
    • 1 Shielded Pair; aluminum-polyester shielding tape plus tinned copper drain wire. Plus:
    • One or more conductors outside the shield.
    • Ripcord included for simple jacket tear-back & removal.
    • PVC jacket. (Gray is standard. Other colors available.)
    35MR 1PR Shielded plus #/C Unshielded; Construction Grade Riser Rated
  • 35MP 1PR Shielded plus #/C Unshielded; Construction Grade Plenum Rated
    • Solid or Stranded Bare Copper Conductors
    • Color Coded Low Smoke PVC insulation (LS-PVC)
    • 1 Shielded Pair; aluminum-polyester shielding tape plus tinned copper drain wire. Plus:
    • One or more conductors outside the shield.
    • Ripcord included for simple jacket tear-back & removal.
    • Low Smoke PVC Jacket. (White is standard. Other colors available.)
    35MP 1PR Shielded plus #/C Unshielded; Construction Grade Plenum Rated
  • In-Wall - Hi Strand Speaker Cable
    • Hi Strand Count – Flexible Bare Copper Conductors; Hi Conductivity Copper
    • Polypropylene insulation for lower capacitance and clear audio response.
    • Ripcord for simple jacket tear-back and removal at termnation.
    • Smooth, round, flexible PVC Jacket.
    • UL Listed for horizontal runs, in-wall installation. Passes UL 1685 Flame Test.
    • Available in boxes or reels; 500ft or 1000ft packaging.
      In-Wall - Hi Strand Speaker Cable
    • 36MR - Riser Rated Access Control - Card Reader Shielded
      • Four cables in one pull for four access control door devices: Card Reader, Magnetic Lock, Door Contact, and Request Exit
      • Each inner cable for separate devices individually jacketed clearly identified
      • Card Reader Cable is shielded. Other inner cables are unshielded.
      • UL Listed for use in risers; Passes UL 1666 Flame Test.
      • UL Listed to UL 13 (CL3R) and UL 444 (CMR)
      • Overall Jacket color is Green (Illustration is representative for this entire product family.)
      36MR - Riser Rated Access Control - Card Reader Shielded
    • 36MP - Plenum Rated Access Control - Card Reader Shielded
      • Four cables in one pull for four access control door devices: Card Reader, Magnetic Lock, Door Contact, and Request Exit
      • Each inner cable for separate devices individually jacketed clearly identified
      • Card Reader Cable is shielded. Other inner cables are unshielded.
      • UL Listed for use in plenum spaces; Passes NFPA 262 Flame Test
      • UL Listed to UL 13 (CL3P) and UL 444 (CMP)
      • Overall Jacket color is Yellow.
      • Southwire Stock Number 577876xx
        36MP - Plenum Rated Access Control - Card Reader Shielded
      • 36SR - Riser Rated Access Control - All Shielded
        • Four cables in one pull for four access control door devices: Card Reader, Magnetic Lock, Door Contact, and Request Exit
        • Each inner cable for separate devices individually jacketed clearly identified
        • All door functions are shielded.
        • UL Listed for use in risers; Passes UL 1666 Flame Test
        • UL Listed to UL 13 (CL3R) and UL 444 (CMR)
        • Overall Jacket color is Yellow.
        • Southwire Stock Number 577923xx
        36SR - Riser Rated Access Control - All Shielded
      • 36SP - Plenum Rated Access Control - All Shielded
        • Four cables in one pull for four access control door devices: Card Reader, Magnetic Lock, Door Contact, and Request Exit
        • Each inner cable for separate devices individually jacketed clearly identified
        • All door functions are shielded.
        • UL Listed for use in plenum spaces; Passes NFPA 262 Flame Test
        • UL Listed to UL 13 (CL3P) and UL 444 (CMP)
        • Overall Jacket color is Yellow.
        • Southwire Stock Number 577925xx
          36SP - Plenum Rated Access Control - All Shielded
        • Home Automation Composite Cables
          • Simplified Structured Cabling
          • Multiple popular combinations of LAN/Data Cat 5e (D) and CATV/Broadband Coax (BB)
          • Combinations with Speaker Cable
          • Combinations with surveillance coax.
          • UL Listed for horizontal runs, in-wall installation. Passes UL 1685 Flame Test.
          Home Automation Composite Cables
        • 333 Category 3 Cable
          • 24AWG  Solid Bare Copper Conductors
          • TIA / ANSI 568  Category 3   and  IEEE 802.3  10 Base T compliant.
          • UL Listed to the applicable NEC requirements for each type (Flame Test Listings)
          333 Category 3 Cable
        • 335 Category 5e Cable
          • 24AWG Solid Bare Copper Conductors
          • Constructed and color-coded to TIA/ANSI standards
          • ETL certified to TIA 568-C.2 Category 5e standards (Electrical testing certifications)
          • UL Listed to the applicable NEC requirements for each type (Flame Test Listings)
          335 Category 5e Cable
        • 336 Category 6 Cable
          • 23AWG Solid Bare Copper Conductors
          • Constructed and color-coded to TIA/ANSI standards
          • ETL certified to TIA 568-C.2 Category 6 standards (Electrical testing certifications)
          • UL Listed to the applicable NEC requirements for each type (Flame Test Listings)
          336 Category 6 Cable
        • 341UR through 342SP Fire Alarm Cable; UL 1424 UL Listed FPLR or FPLP
          • Available in two UL Listed NEC installation ratings:
            • FPLR (Riser)
            • FPLP (Plenum)
          • Available unshielded or shielded
          • Available either solid bare copper, or stranded bare copper.
          • FPLR Unshielded - see Table 341UR (Solid Copper) or 342UR (Stranded Copper)
          • FPLR Shielded - see Table 341SR (Solid Copper) or 342SR (Stranded Copper)
          • FPLP Unhielded - see Table 341UP (Solid Copper) or 342UP (Stranded Copper)
          • FPLP Shielded - see Table 341SP (Solid Copper) or 342SP (Stranded Copper)
          341UR through 342SP Fire Alarm Cable; UL 1424 UL Listed FPLR or FPLP
        • 351CAH-A CCS Dual Shield CATV Coax - Non-Plenum.Rated
          • Copper-Clad-Steel Conductor
          • Foam Polyolefin insulation for 75 Ohm Impedance.
          • Dual Shield: Foil + 60% Aluminum Braid. (Foil is bonded to the dielectric)
          • PVC Jacket. (Black is standard. Other colors available.)
          351CAH-A CCS Dual Shield CATV Coax - Non-Plenum.Rated
        • 351CAH-A CCS Quad Shield CATV Coax - Non-Plenum.Rated
          • Copper-Clad-Steel Conductor
          • Foam Polyolefin insulation for 75 Ohm Impedance.
          • Quad Shield: Foil + 60% Aluminum Braid + 2nd Foil + 2nd Braid 40% Aluminum.
          • 1st Foil is bonded to the dielectric.
          • PVC Jacket. (Black is standard. Other colors available.)
          351CAH-A CCS Quad Shield CATV Coax - Non-Plenum.Rated
        • 351CAH-A 2x Siamese; CCS - Dual Shield CATV Coax - Non-Plenum.Rated
          • Two Coax in Siamese Configuration
          • Copper-Clad-Steel Conductors
          • Foam Polyolefin insulation for 75 Ohm Impedance.
          • Dual Shield: Foil + 60% Aluminum Braid. (Foil is bonded to the dielectric)
          • PVC Jacket. (Black is standard. Other colors available.)
          351CAH-A 2x Siamese; CCS - Dual Shield CATV Coax - Non-Plenum.Rated
        • 351CAH-A 2x Siamese; CCS - Quad Shield CATV Coax - Non-Plenum.Rated
          • Two Coax in Siamese Configuration.
          • Copper-Clad-Steel Conductors.
          • Foam Polyolefin insulation for 75 Ohm Impedance.
          • Quad Shield: Foil + 60% Aluminum Braid + 2nd Foil + 2nd Braid 40% Aluminum.
          • 1st Foil is bonded to the dielectric.
          • PVC Jacket. (Black is standard. Other colors available.)
          351CAH-A 2x Siamese; CCS - Quad Shield CATV Coax - Non-Plenum.Rated
        • 351CAH-B BC - Dual Shield CATV / DBS Coax - Non-Plenum.Rated
          • Bare Copper Conductor (also SBC, Solid Bare Copper)
          • Foam Polyolefin insulation for 75 Ohm Impedance.
          • Dual Shield: Foil + 60% Aluminum Braid. (Foil is bonded to the dielectric)
          • RG6 is also available in foil + 90% Aluminum Braid (Special Order.)
          • PVC Jacket. (Black is standard. Other colors available.)
          351CAH-B BC - Dual Shield CATV / DBS Coax - Non-Plenum.Rated
        • 351CAH-B BC - Quad Shield CATV / DBS Coax - Non-Plenum.Rated
          • Bare Copper Conductor (also SBC, Solid Bare Copper)
          • Foam Polyolefin insulation for 75 Ohm Impedance.
          • Quad Shield: Foil + 60% Aluminum Braid + 2nd Foil + 2nd Braid 40% Aluminum.
          • 1st Foil is bonded to the dielectric
          • PVC Jacket. (Black is standard. Other colors available.)
          351CAH-B BC - Quad Shield CATV / DBS Coax - Non-Plenum.Rated
        • 351CAP-A CCS Dual Shield CATV Coax - Plenum Rated
          • Copper-Clad-Steel Conductor
          • Foam Fluoropolymer insulation for 75 Ohm Impedance.
          • Dual Shield: Foil + 60% Aluminum Braid. (Foil is bonded to the dielectric)
          • LS-PVC Jacket. (White is standard. Other colors available.)
          • UL Listed for use in plenum spaces. Passes NFPA 262 Flame and Smoke Test.
          • UL Listed. CATVP (NEC Article 820) / RG6: UL 444 (CMP)
          351CAP-A CCS Dual Shield CATV Coax - Plenum Rated
        • 351CAP-A CCS Quad Shield CATV Coax - Plenum Rated
          • Copper-Clad-Steel Conductor
          • Foam Fluoropolymer insulation for 75 Ohm Impedance.
          • Quad Shield: Foil + 60% Aluminum Braid + 2nd Foil + 2nd Braid 40% Aluminum.
          • 1st Foil is bonded to the dielectric.
          • LS-PVC Jacket. (White is standard. Other colors available.)
          351CAP-A CCS Quad Shield CATV Coax - Plenum Rated
        • 351CAP-B BC Dual Shield CATV / DBS Coax - Plenum Rated
          • Bare Copper Conductor (also SBC, Solid Bare Copper)
          • Foam Fluoropolymer insulation for 75 Ohm Impedance.
          • Dual Shield: Foil + 60% Aluminum Braid. (Foil is bonded to the dielectric)
          • RG6 is also available in foil + 90% Aluminum Braid (Special Order.)
          • LS-PVC Jacket. (White is standard. Other colors available.)
          351CAP-B BC Dual Shield CATV / DBS Coax - Plenum Rated
        • 351CADB CCS Dual Shield CATV Coaxial Cable - For Outdoor Use - Non-UL
          • Copper-Clad-Steel Conductor
          • Foam Plyolefin insulation for 75 Ohm Impedance.
          • Dual Shield: Foil + 60% Aluminum Braid. (foil is bonded to the dielectric)
          • Polyethylene Outermost Jacket Layer. (Black is standard. other colors available.)
          • Flame Test: N/A - none. Intended for outdoor, non NEC installations.
          351CADB CCS Dual Shield CATV Coaxial Cable - For Outdoor Use - Non-UL
        • 351CADB CCS Quad Shield CATV Coax - Non-UL Outdoor/Underground
          • Copper-Clad-Steel Conductor
          • Foam Polyolefin insulation for 75 Ohm Impedance.
          • Quad Shield: Foil + 60% Aluminum Braid + 2nd Foil + 2nd Braid 40% Aluminum.
          • 1st Foil is bonded to the dielectric.
          • Polyethylene Outermost Jacket Layer. (Black is standard. Other colors available.)
          351CADB CCS Quad Shield CATV Coax - Non-UL Outdoor/Underground
        • Alumaflex™ Type MC XHHW-2
          • UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
          • Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.
          • Anti-short bushings are not required for use with MC cable per the NEC and UL
          Alumaflex™ Type MC XHHW-2
        • AlumaFlex™ Type MC-XHHW-2 PVC Jacketed
          • UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
          • Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.
          • Anti-short bushings are not required for use with MC cable per the NEC and UL
          AlumaFlex™ Type MC-XHHW-2 PVC Jacketed
        • Armorlite ® Type MC - Copper Conductors
          • Copper Power Feeder Conductors.
          • Lightweight Aluminum Interlocked Armor.
          • 600 Volts.
          • THHN/THWN-2 Insulated Singles.
          • Bare Copper Grounding Conductor.
          • Sizes 1 AWG through 750kcmil.
          Armorlite ® Type MC - Copper Conductors
        • Armorlite ® Type MC - PVC Jacketed - Copper Conductors
          • Copper Power Feeder Conductors.
          • Lightweight Aluminum Interlocked Armor with Overall PVC Jacket.
          • 600 Volts.
          • THHN/THWN-2 Insulated Singles.
          • Bare Copper Grounding Conductor.
          • Sizes 1 AWG through 750 kcmil.
          Armorlite ® Type MC - PVC Jacketed - Copper Conductors
        • AlumaFlex™ Type MC AL THHN/THWN-2 Conductors
          • Type MC - 1/0 AWG through 900 kcmil - with triple e TM Aluminum Alloy Lightweight Aluminum Interlocked Armor.
          • 600 Volts.
          • AlumaFlex TM with triple e TM Aluminum Alloy 8000 series (AA8176) Conductors.
          • THHN/THWN-2 Insulated Singles.
          • Bare AlumaFlex TM Aluminum Alloy Grounding Conductor
          AlumaFlex™ Type MC AL THHN/THWN-2 Conductors
        • AlumaFlex ™ Type MC Jacketed AL THHN Conductors
          • Type MC PVC Jacketed - 1/0 AWG through 900 kcmil - with triple e TM Aluminum Alloy Lightweight Aluminum Interlocked Armor with Overall PVC Jacket,
          • 600 volts.
          • AlumaFlex TM with triple e TM Aluminum Alloy 8000 series (AA8176) Conductors.
          • THHN/THWN-2 Insulated Singles.
          • Bare Aluminum Grounding Conductor.
          AlumaFlex ™ Type MC Jacketed AL THHN Conductors
        •  Copper Riser MC Cable

          Ideal for use in vertical high rise applications.

          Available with THHN or XHHW conductors

          Available in custom constructions and lengths

          Polymeric binder jacket over conductors provides continuous conductor support

          Available with Southwire pulling heads and on stacked reels

          Compatible with any fittings and clamps rated for use with standard Type MC

          Copper Riser MC Cable
        •  Aluminum Riser MC Cable
          • Lightweight Aluminum Interlocked Armor. 600 Volts.
          • AlumaFlexTM with triple eTM Aluminum Alloy 8000 series
          • (AA8176)Conductors, THHN/THWN-2 Insulated Singles
          • Bare AlumaFlexTM Aluminum Alloy Grounding Conductor
          Aluminum Riser MC Cable
        • AMERICAN MUSTANG<sup>®</sup> SJOOW
          • American Mustang® 105°C CPE Cord. 300 Volts.
          • Superior Tensile Strength and Aging Characteristics.
          • Black Jacket. Rated -40°C to 105°C.
          • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use.
          • Provides Premium Oil Resistance, Water Resistant and High Flexibility .
          • Excellent Abrasion Resistance.
          AMERICAN MUSTANG® SJOOW
        • American Mustang<sup>®</sup> SOOW Black
          • American Mustang® 105°C CPE Cord. 600 Volts.
          • Superior Tensile Strenght, Elongation and Aging Characteristics.
          • Black Jacket. Rated -40°C to 105°C.
          • Provides Premium Oil Resistance, Water Resistant and High Flexibility .
          • Excellent Abrasion Resistance.
          American Mustang® SOOW Black
        • American Mustang SJOOW Yellow
          • American Mustang® Flexible Cord 300 Volts.
          • EPDM Insulation. CPE Yellow Jacket. Rated -40°C to 105°C.
          • UL Listed and CSA Certified for Indoor and Outdoor Use.
          • Rated Hard Useage. RoHS Compliant.
          American Mustang SJOOW Yellow
        • American Mustang SOOW Yellow
          • American Mustang® 105°C CPE Cord. 600 Volts
          • Superior Tensile Strength, Elongation and Aging Characteristics
          • RoHS Compliant Yellow Jacket. Rated -40°C to 105°C
          • UL Listed and CSA Certified for Indoor and Outdoor Use
          • Provides Premium Oil, Acid, and Water Resistance
          • High Flexibility and Excellent Abrasion Resistance.LI>
          American Mustang SOOW Yellow
        • Seoprene® Type TPE SJEOOW
          • Seoprene® SJEOOW 105°C TPE Cord. 300 Volts.
          • Black Jacket. Rated -50°C to 105°C. RoHS Compliant
          • Rated as Hard-Usage Service Cord.
          • Sizes 18 AWG - 10 AWG CSA Certified as Type SJTOOW (TPE) and meets CSA FT-2.
          • Listed for Outdoor Use. Provides Premium Oil Resistance, Water Resistance and Flexibility.
          Seoprene® Type TPE SJEOOW
        • QuantumTPE SJEOOW Yellow
          • Quantum™ 105°C TPE Cord. 300 Volts. Flexible Copper Conductors.
          • Extra Flexible Thermoplastic-Elastomer (TPE) Insulation and Jacket.
          • Yellow Jacket.  Rated -50°C to 105°C. RoHS Compliant.
          • Rated as Hard-Usage Service Cord.
          • CSA Approved as Type SJTOOW (TPE) at -50°C to 105°C and meets CSA FT-2.
          • Listed for Outdoor Use. Provides Premium Oil Resistance, Water Resistance and Flexibility.
          QuantumTPE SJEOOW Yellow
        • Seoprene® Type TPE SEOOW
          • Seoprene® SEOOW 105°C TPE Cord. 600 Volts.
          • Black Jacket. Rated -50°C to 105°C. RoHS Compliant
          • Rated as Extra Hard-Usage Service Cord.
          • Sizes 18 AWG - 10 AWG CSA Certified as Type STOOW (TPE) and meet CSA FT-2.
          • Sizes 8-2 AWG are non-UL and non-CSA Listed.
          • Listed for Outdoor Use. Provides Premium Oil Resistance, Water Resistance and Flexibility.
          Seoprene® Type TPE SEOOW
        • QuantumTPE SEOOW Yellow
          • Quantum™ 105°C TPE Cord. 600 Volts. Flexible Copper Conductors.
          • Extra Flexible Thermoplastic-Elastomer (TPE) Insulation and Jacket.
          • Yellow Jacket. Rated -50°C to 105°C. RoHS Compliant.
          • Rated as Extra Hard-Usage Service Cord.
          • Sizes 18 AWG - 10 AWG CSA Certified as Type STOOW (TPE) and meet CSA FT-2.
          • Sizes 8-2 AWG are non-UL and non-CSA Listed.
          • Approved for Outdoor Use. Provides Premium Oil Resistant, Water Resistace and Flexibility.
          QuantumTPE SEOOW Yellow
        • Royal® Type SJOOW
          • Royal® 90°C Cord. 300 Volts.
          • Good Tensile Strength, Elongation and Aging Characteristics.
          • Black Jacket. Rated -40°C to 90°C.
          • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use.
          • Provides Premium Oil Resistance, Water Resistant and High Flexibility.
          • Excellent Abrasion Resistance.
          • NEC, Rated Hard Usage.
          Royal® Type SJOOW
        • Viper Rubber Type SJOOW Yellow
          • VIPER® 90°C CPE Cord. 300 Volts
          • Good Tensile Strength, Elongation and Aging Characteristics
          • Yellow Jacket. Rated -40°C to 90°C
          • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use
          • Provides Premium Oil Resistance, Water Resistant and High Flexibility
          • Excellent Abrasion Resistance
          • NEC, Rated Hard-Usage
          Viper Rubber Type SJOOW Yellow
        • Viper Rubber Type SOOW Black
          • VIPER® 90°C CPE Cord. 600 Volts
          • Flexible Stranding. Flame and Ozone Resistant
          • Black Jacket. Rated -40°C to 90°C
          • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use
          • Provides Premium Oil Resistance, Water Resistant and High Flexibility
          • Excellent Abrasion Resistance
          • NEC, Rated Extra-Hard Usage
          Viper Rubber Type SOOW Black
        • Viper Rubber Type SOOW Yellow
          • VIPER® 90°C Cord. 600 Volts.
          • Flexible Stranding. Flame and Ozone Resistant.
          • Yellow Jacket. Rated -40°C to 90°C.
          • RoHS Compliant.
          • UL Listed and CSA Certified for Indoor and Outdoor Use.
          • Provides Premium Oil Resistance, Water Resistance and High Flexibility.
          • Excellent Abrasion Resistance.
          • NEC, Rated Extra Hard-Usage.
          Viper Rubber Type SOOW Yellow
        • Royal<sup>®</sup> Multi-Conductor SOOW
          • Royal® 90°C Rubber Cord. 600 Volts.
          • Flexible Stranding. Flame and Ozone Resistant.
          • Black Jacket. Rated -40°C to 90°C.
          • RoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use.
          • Provides Premium Oil Resistance, Water Resistant and High Flexibility.
          • Excellent Abrasion Resistance. Rated Extra-Hard Usage.
          Royal® Multi-Conductor SOOW
        • Royal<sup>®</sup> Non UL/Non CSA SOOW
          • 90°C, 600 Volt Cord
          • Ozone and Flame Resistant
          • Black Jacket. Rated -40°C to 90°C
          • RoHS Compliant. Indoor and Outdoor Use
          Royal® Non UL/Non CSA SOOW
        • Viper® Non UL/Non CSA SOW
          • 90°C, 600 Volt Cord
          • Ozone and Flame Resistant
          • Black CPE Jacket. Rated -40°C to 90°C
          • RoHS Compliant. Indoor and Outdoor Use
          • Provides Moisture and Oil Resistance
          Viper® Non UL/Non CSA SOW
        • Type STOW - Plastic (PVC)
          • 105°C to -40°C 600 Volts. PVC Jacket
          • Sunlight, Moisture and Oil Resistant
          Type STOW - Plastic (PVC)
        • Type SJTOW - Plastic (PVC)
          • 60°C to -40°C 300 Volts. PVC Jacket
          • Sunlight, Moisture and Oil Resistant
          • UL Listed And CSA Certified
          Type SJTOW - Plastic (PVC)
        • Type SJTOOW - Plastic (PVC)
          • 105°C PVC Cord. 300 Volts. Flexible Copper Conductors.
          • Flexible PVC  Insulation and Jacket.
          • Grey or Yellow Jacket.  Rated -34°C to 105°C. Rated as Hard-Usage Service Cord.
          • Flame Retardant and Meets UL and CSA FT2 Flame Tests.
          • Approved for Outdoor Use. Provides Premium Oil Resistance, Water Resistant, and Flexibility.
          Type SJTOOW - Plastic (PVC)
        • Type STOOW - Plastic (PVC)
          • 105°C PVC Cord. 600 Volts. Flexible Copper Conductors.
          • Flexible PVC Insulation and Jacket.
          • Grey or Yellow Jacket. Rated -34°C to 105°C. Rated as Extra Hard-Usage Service Cord.
          • Flame Retardant and Meets UL and CSA FT2 Flame Tests.
          • Approved for Outdoor Use. Provides Premium Oil Resistance, Water Resistant, and Flexibility.
          Type STOOW - Plastic (PVC)
        • SVT Cord
          • Stranded Copper Conductors.
          • 300 Volts; 60 or 105°C.
          • PVC Jacket
          SVT Cord
        • SPT
          • Rated 300 Volts. Rated 105°C or 60°C.
          • Stranded Copper Conductors.
          • Color Coded PVC Insulation/Jacket.
          SPT
        • Alflex ® - Type RWA
          • Aluminum Flexible Metal Conduit. High Strength Aluminum Alloy Strip
          • 5/16" is UL Recognized Component. UL Listed in sizes 3/8" to 3"
          • 600 Volt
          Alflex ® - Type RWA
        • Galflex ® - Type RWS
          • Steel Flexible Metal Conduit. High Strength Steel Strip.
          • UL Recognized Component in 5/16". UL Listed in 3/8" through 3".
          • CSA Listed for Trade Sizes 5/16" and 3/8" Available Upon Request.
          Galflex ® - Type RWS
        • Alflex ® - Type SWA
          • Aluminum Flexible Metal Conduit
          • High Strength Aluminum Alloy Strip
          • Size 5/16" UL Recognized Component
          • UL Listed in Sizes 3/8" and Larger
          • CSA listed
          Alflex ® - Type SWA
        • Titan2™ - Type UL
          • Liquidtight Flexible Metal Conduit.
          • UL Listed.
          • CSA Listed.
          • Oil-Resistant.
          • Sunlight-Resistant.
          • Temperature Rated -30oC to 80oC.
          Titan2™ - Type UL
        • Titan ® - Type CB
          • Liquidtight Flexible Metal Conduit.
          • Easy to Identify Blue Jacket for Computer Applications.
          • UL/CSA Listed.
          • Oil-Resistant.
          • Sunlight-Resistant.
          • Temperature Rated -30oC to 80oC.
          Titan ® - Type CB
        • Titan ® - Type EF and AEF
          • Extra-Flexible Liquidtight Metal Conduit.
          • Steel or Aluminum Constructions.
          • General Purpose Use.
          • Oil-Resistant.
          • Sunlight-Resistant.
          • Temperature Rated -10°C to 60°C.
          Titan ® - Type EF and AEF
        • Data-Flex ®
          • Flexible Metal Conduit
          • Crush/corrosion resistant
          • Smooth interior for easy pulling
          Data-Flex ®
        • Slinky-Flex ® - Type SF
          • Extra Flexible Metal Conduit.
          • Allows "U" Bends for Tight Applications.
          Slinky-Flex ® - Type SF
        • Ultratite ® - Type NMHC
          • Hot/Cold Liquidtight Flexible Nonmetallic Conduit.
          • Oil-Resistant.
          • Sunlight-Resistant.
          • Crush-Resistant.
          • UL/CSA Listed.
          • Temperature Rated -40oC to 105oC.
          Ultratite ® - Type NMHC
        • Ultratite ® - Type NMOR
          • Oil Resistant Liquidtight Flexible Nonmetallic Conduit.
          • UL/CSA Listed.
          • Sunlight-Resistant.
          • Crush-Resistant.
          • Temperature Rated -30oC to 80oC.
          Ultratite ® - Type NMOR
        • Ultratite ® - Type NM
          • Liquidtight Flexible Nonmetallic Conduit.
          • UL/CSA Listed
          • Oil resistant 
          • Sunlight-Resistant.
          • Crush-Resistant.
          • Temperature Rated -30oC to 80oC.
          Ultratite ® - Type NM
        • American Mustang ® Orange Welding Cable
          • Premium Grade Orange CPE Jacket. . 
          • Superior Flexibility, Flame Retardant, Oil and Solvents Resistant.
          • Weather and Ozone Resistant.
          • 105°C to -55°C 600 Volt.

          American Mustang ® Orange Welding Cable
        • Red Welding Cable
          • 600 Volts. Rated for -55°C to 105°C. Sizes 6 AWG - 500 MCM.
          • Good Flexibility. Oil Resistant.
          • Resists Compression, Cuts and Abrasion.
          • Red EPDM Jacket, RoHS Compliant.
          Red Welding Cable
        • Black non-UL Welding Cable
          • 600 Volts. Rated for -55°C to 105°C. Sizes 6 AWG - 500 MCM.
          • Good Flexibility. Oil Resistant.
          • Resists Compression, Cuts and Abrasion.
          • Black EPDM Jacket, RoHS Compliant.
          Black non-UL Welding Cable
        • 2KV Diesel Locomotive Cable
          • 2000 V
          • 90°C
          • MSHA Accepted
          • UL Listed as Type RHH/RHW-2
          • CT Rated
          • RoHS Compliant
          2KV Diesel Locomotive Cable
        • Type W Portable Power Cable
          • Type W Industrial Grade Single and Multiconductor Portable Round Power Cable
          • 2000 Volt. 90°C (-40°C). Oil and Sunlight Resistant.
          • Single Conductors Listed as Type RHH/RHW-2.
          • UL and c(UL) Listed. CSA Certified. MSHA Approved. RoHS Compliant.
          Type W Portable Power Cable
        • Type SC Entertainment Cable
          • Type SC Entertainment Cable. 600 Volts. Extra Flexible Copper Conductors.
          • Water and Sunlight Resistant. Designed to Withstand Severe Environmental Conditions. 
          • 105°C to -40°C. Listed for Indoor or Outdoor Use. Flame Retardant.
          • Provides Flexibility, Resistance to Oil, Solvents, Ozone, Aging, and Abrasion.
          Type SC Entertainment Cable
        • Bus Drop Cable
          • Resistant to Oils, Lubricants, Acids, Alkalies, Ozone, Water and Abrasion.
          • One Uninsulated Ground Conductor per Interstice. Used in Wet or Dry Locations. 600 Volt.
          • UL Listed. OSHA Acceptable. RoHSCompliant. -20°C to 75°C(14-8 awg), 60°C (6-2 awg).
          Bus Drop Cable
        • Temporary Jumper Cable
          • Single Conductor
          • 4 AWG - 500 kcmil
          • 90°C Damp or Dry Locations
          • 5/15kV EPR Insulation, Non-Shielded
          Temporary Jumper Cable
        • Canadian Type G-GC and Type G Round
          • 2000 Volts. 90°C(-40°C). Sunlight and Oil Resistant.
          • UL and c(UL) Listed, MSHA Approved, and RoHS Compliant.
          Canadian Type G-GC and Type G Round
        • Type G and Type G-GC Round
          • 2000 Volts. 90°C(-40°C). Sunlight and Oil Resistant.
          • UL and c(UL) Listed, MSHA Approved, and RoHS Compliant.
          Type G and Type G-GC Round
        • Royal <sup>®</sup> Type SOOW
          • 90°C, 600 Volts. Flexible Stranding. Water Resistant 60°C.
          • Black Jacket. Rated -40°C to 90°C. RoHS Compliant.
          • UL Listed and CSA Certified for Indoor and Outdoor Use.
          • 18 AWG - 10 AWG - Multi-conductor Shielded
          Royal ® Type SOOW
        • TelcoSafe® I
          • 600 Volts, Copper Conductor
          • Central Office Power Wire and Cable
          • Flexible Central Office Power Wire and Cable
          • CSA approved, Non-Halogen Insulation
          • 8 AWG thru 750 KCMIL - Single Conductor
          • 90°C Dry, 75°C Wet to -40°C
          TelcoSafe® I
        • TelcoFlex® II
          • 600 Volts, Copper Conductor  
          • Class l Flexible Strand Without Braid
          • CSA Approved, Non-Halogen  Insulation
          • 8 AWG thru 750 KCMIL - Single Conductor
          TelcoFlex® II
        • TelcoFlex® III
          • 600 Volts, Copper Conductor
          • Central Office / Telecom Power Cable
          • Class B Strand With Braid
          • CSA approved, Non-Halogen Insulation
          • 14 AWG - 750 KCMIL - Single Conductor
          TelcoFlex® III
        • TelcoFlex® IV
          • 600 Volts, Copper Conductor  
          • Class l Flexible Strand With Braid
          • CSA approved, Non-Halogen Insulation
          • 8 AWG - 750 KCMIL - Single Conductor
          TelcoFlex® IV
        • Lite-Whip Pre-Assembled  (Steel Flex 6' Fixture Whips)
          • Interlocked Steel Armor with Factory Installed Conductors.
          • Factory Installed Lock-nut or Snap-in Fittings. 600 Volts.
          • Sizes 18 and 16 AWG Copper TFN or TFFN Conductors.
          • Sizes 14 and 12 AWG Copper THHN/THWN Conductors.
          • Green Insulated Copper Grounding Conductor.
          Lite-Whip Pre-Assembled (Steel Flex 6' Fixture Whips)
        • Modular Assemblies
          • 14 AWG through 10 AWG THHN/THWN Insulated Singles
          • Green Insulated Ground
          • UL Listed
          • 600 Volts
          • Rated VW-1
          • Lightweight Aluminum Interlocked Armor
          • Includes UL Listed Fittings and Prepared Cable Ends

           

          Modular Assemblies
        • Ultra-Whip (Non-Metallic Hook-Up Whips)
          • 600 Volt. Stranded Copper THHN/THWN Insulated Singles.
          • Green Insulated Copper Grounding Conductor.
          • Highly Flexible Non-metallic Conduit with Factory Installed Conductors.
          • Liquidtight Flexible Non-metallic Conduit Type B (LFNC-B) Fittings.
          • Intended for 208/240/480 Volt Single Phase Circuits.
          Ultra-Whip (Non-Metallic Hook-Up Whips)
        • AAAC-6201
          • All Aluminum-Alloy Conductor.
          • Bare.
          AAAC-6201
        • AAC
          • All Aluminum Conductor.
          • Bare.
          AAC
        • ACSR
          • Aluminum Conductor.
          • Steel Reinforced.
          • Bare.
          ACSR
        • ACSR/AW
          • Aluminum Conductor.
          • Aluminum-Clad Steel Reinforced.
          • Bare.
          ACSR/AW
        • ACAR
          • Aluminum Conductor.
          • Aluminum Alloy Reinforced.
          • Bare.
          ACAR
        • ACSR/TW
          • Aluminum Conductor.
          • Steel Reinforced.
          • Trapezoidal Shaped Aluminum Strands.
          • Bare.
          ACSR/TW
        • AAC/TW
          • All Aluminum Conductor.
          • Trapezoidal Shaped Conductors.
          • Bare.
          AAC/TW
        • Motion-Resistant Conductor
          • ACSR Motion-Resistant Conductor.
          • Bare Aluminum Conductor, Steel Reinforced.
          Motion-Resistant Conductor
        • VR2 Cable
          • Vibration-Resistant.
          • Bare Aluminum Cable.
          • Available in AAC and ACSR Constructions.
          VR2 Cable
        • ACSS
          • Aluminum Conductor, Steel Supported.
          • Bare
          ACSS
        • ACSS/AW
          • Aluminum Conductor.
          • Aluminum-Clad Steel Supported.
          ACSS/AW
        • ACSS/TW
          • Aluminum Conductor, Steel Supported.
          • Trapezoidal Shaped Aluminum Strands.
          • Bare.
          ACSS/TW
        • Armor Wire/Binder Tape
          • Aluminum Armor Wire and Binder Tape.
          • Rectangular Soft 1350 Aluminum Alloy.
          Armor Wire/Binder Tape
        • Tie & Ground Wire
          • Aluminum Tie and Ground Wire.
          • Solid Soft 1350 Aluminum Alloy.
          Tie & Ground Wire
        • Covered Line Wire
          • Aluminum Conductor.
          • Polyethylene or Crosslinked Polyethylene Covering.
          Covered Line Wire
        • Parallel Aerial Cable
          • Parallel Aerial Cable.
          • Aluminum Conductors.
          • High Density Polyethylene or Crosslinked Polyethylene Insulation.
          Parallel Aerial Cable
        • Reverse Twist Secondary
          • Reverse Twist Secondary.
          • Aluminum Conductors.
          • High Density Polyethylene or Crosslinked Polyethylene Insulation.
          Reverse Twist Secondary
        • Single Conductor 600V
          • Aluminum Conductor.
          • Cross-linked Polyethylene (XLP) Insulation.
          Single Conductor 600V
        • Duplex 600V Secondary UD
          • Aluminum Conductors.
          • Cross-linked Polyethylene (XLP) Insulation.
          Duplex 600V Secondary UD
        • Triplex 600V Secondary UD
          • Aluminum Conductors.
          • Cross-linked Polyethylene (XLP) Insulation.
          Triplex 600V Secondary UD
        • Quadruplex 600V
          • Aluminum Conductors.
          • Cross-linked Polyethylene (XLP) Insulation.
          Quadruplex 600V
        • HI-SCORE Single Conductor 600V
          • Aluminum Conductor.
          • Ruggedized XLP Insulation.
          • Provides Superior Mechanical Protection.
          HI-SCORE Single Conductor 600V
        • HI-SCORE Duplex 600V
          • Aluminum Conductors.
          • Ruggedized XLP Insulation.
          • Provides Superior Mechanical Protection.
          HI-SCORE Duplex 600V
        • HI-SCORE Triplex 600V
          • Aluminum Conductor.
          • Ruggedized XLP Insulation.
          • Provides Superior Mechanical Protection.
          HI-SCORE Triplex 600V
        • HI-SCORE Quadruplex 600V
          • Aluminum Conductors.
          • Ruggedized XLP Insulation.
          • Provides Superior Mechanical Protection.
          HI-SCORE Quadruplex 600V
        • SureSeal® Duplex 600V
          • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
          • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
          • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
          SureSeal® Duplex 600V
        • SureSeal® Triplex 600V
          • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
          • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
          • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
          SureSeal® Triplex 600V
        • SureSeal® Quadruplex 600V
          • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
          • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
          • Sealant also provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
          SureSeal® Quadruplex 600V
        • SureSeal® Single Conductor 600V
          • Unique Cable Design with an Encapsulated Flowable Visco-Elastic Sealant.
          • Sealant Provides Extended Cable Life After Minor Mechanical Cable Damage.
          • Sealant also Provides Extended Cable Life when Pinholes are Caused by Voltage Surges.
          SureSeal® Single Conductor 600V
        • 8000 Series AL Triplex 600V
          • TRIPLE E Aluminum Alloy (AA-8176) Conductors.
          • Cross-linked Polyethylene (XLP) Insulation.
          8000 Series AL Triplex 600V
        • Quadruplex 600V Secondary UD RHH or RHW-2 or USE-2 AlumaFlex®
          • TRIPLE E Aluminum Alloy (AA-8176) Conductors.
          • Cross-Linked Polyethylene (XLP) Insulation.
          Quadruplex 600V Secondary UD RHH or RHW-2 or USE-2 AlumaFlex®
        • PowerGlide Triplex 600V
          • Aluminum conductor
          • Cross-linked polyethylene (XLP) insulation
          • Easy to pull or push
          PowerGlide Triplex 600V
        • PowerGlide Quadruplex 600V
          • Aluminum Conductor
          • Cross-linked Polyethylene (XLP) Insulation
          • Easy to Pull or Push
          PowerGlide Quadruplex 600V
        • PowerGlide HI-SCORE Triplex 600V
          • Aluminum Conductor.
          • Ruggedized Cross-linked Polyethylene (XLP) Insulation.
          • Provides Superior Mechanical Protection.
          • Easy to Pull or Push.
          PowerGlide HI-SCORE Triplex 600V
        • PowerGlide HI-SCORE Quadruplex 600V
          • Aluminum Conductor.
          • Ruggedized Cross-linked Polyethylene (XLP) Insulation.
          • Provides Superior Mechanical Protection.
          • Easy to Pull or Push.
          PowerGlide HI-SCORE Quadruplex 600V
        • 15kV HI-DRI UD
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          15kV HI-DRI UD
        • 25kV HI-DRI UD
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          25kV HI-DRI UD
        • 28kV HI-DRI UD
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          28kV HI-DRI UD
        • 35kV HI-DRI UD
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          35kV HI-DRI UD
        • 15kV HI-DRI Jacketed
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Low Density Polyethylene Jacket.
          15kV HI-DRI Jacketed
        • 25kV HI-DRI Jacketed
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Low Density Polyethylene Jacket.
          25kV HI-DRI Jacketed
        • 28kV HI-DRI Jacketed
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Low Density Polyethylene Jacket.
          28kV HI-DRI Jacketed
        • 35kV HI-DRI Jacketed
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Low Density Polyethylene Jacket.
          35kV HI-DRI Jacketed
        • 46kV HI-DRI Jacketed
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Low Density Polyethylene Jacket.
          46kV HI-DRI Jacketed
        • LCT Shielded Primary UD TRXLP Cable
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Copper Longitudinal Corrugated Tape Shield (LCT).
          • Low Density Polyethylene Jacket.
          LCT Shielded Primary UD TRXLP Cable
        • 15kV PowerGlide MV Primary UD Cable
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Engineered PowerGlide™ Polyethylene Jacket.
          15kV PowerGlide MV Primary UD Cable
        • 25kV PowerGlide MV Primary UD Cable
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Engineered PowerGlide™ Polyethylene Jacket.
          25kV PowerGlide MV Primary UD Cable
        • 28kV PowerGlide MV Primary UD Cable
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Engineered PowerGlide™ Polyethylene Jacket.
          28kV PowerGlide MV Primary UD Cable
        • 35kV PowerGlide MV Primary UD Cable
          • Aluminum or Copper Conductor.
          • TRXLP Insulation.
          • Bare Copper Concentric Neutrals.
          • Engineered PowerGlide™ Polyethylene Jacket.
          35kV PowerGlide MV Primary UD Cable
        • LCT Shielded PowerGlide MV Primary UD Cable
          • Aluminum or Copper Conductors.
          • TRXLP Insulation.
          • Copper Longitudinal Corrugated Tape Shield (LCT).
          • Engineered PowerGlide™ Polyethylene Jacket.
          LCT Shielded PowerGlide MV Primary UD Cable
        • EPEC-11 CIC SIMpull
          • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
          • EPEC-11 Wall Thicknesses.
          EPEC-11 CIC SIMpull
        • EPEC-13.5 CIC SIMpull
          • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
          • EPEC-13.5 Wall Thicknesses.
          EPEC-13.5 CIC SIMpull
        • EPEC-17 CIC SIMpull
          • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
          • EPEC-17 Wall Thicknesses.
            EPEC-17 CIC SIMpull
          • EPEC-40 CIC SIMpull
            • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
            • EPEC-40 Wall Thicknesses.
            EPEC-40 CIC SIMpull
          • EPEC-80 CIC SIMpull
            • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
            • EPEC-80 Wall Thicknesses.
              EPEC-80 CIC SIMpull
            • SIMpull® Cable-in-Conduit Standard Wall
              • High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
              • Standard Wall Thicknesses.
                SIMpull® Cable-in-Conduit Standard Wall
              • HV Cable System Options
                • Feasibility studies and conceptual engineering
                • Detailed underground system design
                • Pulling calculations
                HV Cable System Options
              • 161kV
                • Compressed Round or Compacted Segmental Conductor
                • Corrugated Metallic Sheath or Cu Laminate Sheath
                • True Triple Extrusion
                • Super Clean XLPE Insulation
                161kV
              • 115kV
                • Compressed Round or Compacted Segnental Conductor
                • Corrugated Metallic Sheath or Cu Laminate Sheath
                • True Triple Extrusion
                • Super Clean XLPE Insulation
                • Insulation thickness 550 mils-800 mils
                115kV
              • 69kV
                • Compressed Round or Compacted Segmental Conductor
                • Corrugated Metallic Sheath or Cu Laminate Sheath
                • True Triple Extrusion
                • Super Clean XLPE Insulation
                • Insulation thickness 450 mild-650 mils
                69kV
              • 138kV
                • Compressed Round or Compacted Segmental Conductor
                • Corrugated Metallic Sheath or Cu Laminate Sheath
                • True Triple Extrusion
                • Super Clean XLPE Insulation
                • Insulation thickness 650 mils-850 mils
                138kV
              • 230kV
                • Compressed Round or Compacted Segmental Conductor
                • Corrugated Metallic Sheath or Cu Laminate Sheath
                • True Triple Extrusion
                • Super Clean XLPE Insulation
                • Insulation thickness 850 mils-900 mils
                230kV
              • Outdoor Porcelain Termination
                • Premolded Stress Control System
                • Silicon Fluid Filled
                • Epoxy Standoff Insulators
                • Porcelain Insulator
                • Available from 69kV-230kV
                Outdoor Porcelain Termination
              • Dry Type Plug In Termination
                • Silicone Rubber Stress Cone
                • Plugs into Switchgear Connector
                • Mechanical Screw Top Connector
                • Available up to 145kV
                Dry Type Plug In Termination
              • Epoxy Insulator Termination
                • Silicone Rubber Stress Cone
                • Plugs into Swithgear Connector
                • Mechanical Screw Top Connector
                • Available up to 145kV
                Epoxy Insulator Termination
              • Joint
                • Premolded Joint
                • 3 Piece Design
                • Screw top or Compressed Conductor Connector
                • Compact Dimensions
                • Available from 69kV-230kV
                Joint
              • FEV-V Outdoor Termination with Composite Insulator
                • Premolded Stress Control System
                • Silicon Fluid Filled
                • Epoxy Standoff Insulators
                • Composite Insulator
                • Available from 69kV-230kV
                FEV-V Outdoor Termination with Composite Insulator
              • Aluminum Cable Clamps
                Aluminum Cable Clamps
              • Bonding Cable
                Bonding Cable
              • Link Boxes
                • Stainless steel box
                • Moisture tight and water impervious options available for both outdoor and vault applications
                • Suitable for all voltage classes
                • Zinc oxide sheath voltage limiters
                • Single point, cross-bonding, and direct grounding versions available, with or without removable links
                • Accommodates single core or concentric bonding cables of different diameters
                • 1 phase and 3 phase boxes
                • Different mechanical protection levels up to IP68
                • Short circuit current up to 40 kA for 1 sec
                Link Boxes
              • 5kV Covered Aerial MV Cable - Tree Wire
                • B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
                • B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors.
                • B-232 Concentric-Lay-Stranded, Aluminum Conductors, Coated Steel Reinforced (ACSR).
                • B-498 Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
                • B-399 Standard Specification for Concentric-Lay-Stranded, Aluminum Alloy 6201-T81 Conductors.
                5kV Covered Aerial MV Cable - Tree Wire
              • Multi-Layer 15kV - 46kV Spacer Cable
                • Aluminum Conductor.
                • Track-Resistant HD Polyethylene or Track Resistant Crosslinked polyethylene Covering.
                Multi-Layer 15kV - 46kV Spacer Cable
              • Multi-Layer 15kV - 35kV Tree Wire
                • Aluminum Conductor.
                • Track-Resistant HD Polyethylene or Track-Resistant Crosslinked Polyethylene Covering.
                Multi-Layer 15kV - 35kV Tree Wire
              • Messenger
                • High Strength to Weight
                • Equivalent Conductivity to Bare Aluminum
                • Protects covered conductors from physical damage
                • Superior corrosion resistance
                Messenger
              • 15kV Polymer Insulator
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • Insulator is molded from grey track resistant polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                15kV Polymer Insulator
              • 15kV Polymer Vise-Top Insulator
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • Insulator is molded from grey track resistant polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                • Special clamp with torque colibrated holding bolts
                • Available for both covered and bare conductors
                15kV Polymer Vise-Top Insulator
              • 35kV Polymer Insulator
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • Insulator is molded from a track resistant polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                35kV Polymer Insulator
              • 35kV Polymer Vise-Top Insulator
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • Insulator is molded from grey track resistant polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                • Special clamp with torque calibrated holding bolts
                • Can be easily used in hot stick applications
                • Nylon inserts for covered conductors
                • Metallic inserts for bare conductors
                35kV Polymer Vise-Top Insulator
              • Tie Wire
                • Compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • Compatible with Southwire's and other manufacturers' SCS accessories
                • UV resistant
                • Flexible and easy to install
                • Track resistant
                Tie Wire
              • Torque Bolt
                • Special reduced cross section that is calibrated to provide the optimum clamping force for this cable with break-off eye
                • UV resistant
                • Lightweight and shatter resistant
                Torque Bolt
              • Vise-Top Stringing Tool
                • Stringing Tool molded from a polyurethane compound
                • Lightweight and shatter resistant
                • Designed to be operated either by hot stick or by hand
                • Designed for low friction by hot stick or by hand
                • Designed for low friction with both pulling rope and covered conductors.
                • Easy to install and remove
                Vise-Top Stringing Tool
              • Ring Ties
                • Compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • Ring Ties are molded from a long life track resistant silicone compound
                • UV resistant
                Ring Ties
              • 46kV RatchetLock Spacer
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • RatchetLock Spacer is molded from a track-resistant high-density polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                • Does not require seperate ring ties
                46kV RatchetLock Spacer
              • 35kV Spacer
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • 35kV Spacer is molded from grey high-density track-resistant polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                35kV Spacer
              • 15kV Three Phase Vertical Spacer
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • 15kV 3-Phase Vertical Spacer is molded from grey track-resistant high-density polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                15kV Three Phase Vertical Spacer
              • 15kV Spacer
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • 15kV Spacer is molded from grey high-density track resistant polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                • Can be used on any 5kV - 15kV Covered Aerial MV system
                15kV Spacer
              • 15kV Single Phase Spacer
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • 15kV Single Phase Spacer is molded from grey track-resistant polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                15kV Single Phase Spacer
              • 15kV RatchetLock Spacer
                • Dielectrically compatible with Southwire polyethylene covered conductors or other polyethylene covered conductors
                • RatchetLock Spacer is molded from grey track-resistant high-density polyethylene compound
                • UV resistant
                • Lightweight and shatter resistant
                • Does not require seperate ring ties
                15kV RatchetLock Spacer
                • Manufactured from high-strength structural steel
                • Corrosion resistant
                • Maintains proper Covered Aerial MV cable orientation
                • Drilled for use on standard utility poles
                "C" Bracket
                • Manufactured from high-strength structural steel
                • Corrosion resistant
                • Maintains proper Covered Aerial MV cable orientation
                • Drilled for use on standard utility poles
                "E" Bracket
              • Anti-sway Bracket
                • Designs that allow flexibility in attachment to the pole
                • Compatible and interchangeable with other manufacturers accessories
                • Lightweight and shatter resistant
                • UV resistant
                Anti-sway Bracket
              • Dead-end Bracket
                • Manufactured from high strength structural steel
                • Corrosion resistant
                • Allows for compact configuration for dead-ending
                • Drilled for use on standard utility poles
                • Uses Standard "C" Bracket and Angle Cross Arm increasing part interchangeability
                Dead-end Bracket
              • Double Insulator Plate
                • Manufactured by casting from ductile iron
                • Corrosion resistant
                • Drilled for 10" insulator spacing
                Double Insulator Plate
              • Messenger Angle Clamps
                • Excellent corrosion resistance
                • Designed to hold up to 14,000 pounds
                • For line angles of up yo 60 degrees
                Messenger Angle Clamps
              • Messenger Clamp
                • Corrosion resistant
                • Designed to allow roll-by installation of Covered Aerial MV cables
                • Will support a wide range of messenger sizes
                Messenger Clamp
              • Tangent
                • Ductile iron construction for higher strength
                • Low profile design without loss of strength
                • Corrosion resistant
                Tangent "L" Bracket
              • Tangent
                • Corrosion resistant
                • Optimally shaped to provide high strength and to maintain optimum cable configuration
                • Enable conductor support at structure and use of anti-sway bracket
                • Attachment hardware provided
                Tangent "L" Bracket Stirrup
              • Transformer Tap Bracket
                • manufactured from-strength structural stell channel
                • Excellent corrosion resistance
                • Provides increased Covered Aerial MV cable spacing to facilitate operations
                Transformer Tap Bracket
              • U-Bolt
                • Excellent corrosion resistance
                • 1 1/2" hole spacing
                • 4 1/2" total length
                • Includes mounting nuts and washers
                U-Bolt
              • Vertical Tap Bracket
                • Manufactured from high-strength structural steel
                • Corrosion resistant
                • Drilled for use on standard utility poles
                • Allows for tap circuit connections with adequate room for connections in minimal space
                Vertical Tap Bracket
              • Messenger Dead-ends
                • Longitudinal Holding Strength equal to messenger UTS
                • Uniform radial pressure exerted on the messenger
                • Designed for specific messenger sizes
                • Color coded for ease of selection in field
                Messenger Dead-ends
              • Aluminum Wedge Dead-end
                • Ease of installation
                • Designed for specific conductor diameters
                • Compatible with all manufacturers’ Covered Aerial MV cable and Tree Wire
                Aluminum Wedge Dead-end
              • Clevises
                • Excellent corrosion resistance
                Clevises
              • Coated Conductor Dead-ends
                • Longitudinal hold strength for spacer cable applications
                • Uniform radial pressure exerted on the conductor cover
                • Designed for specific conductor diameters
                • Color coded for ease of selection in field
                • Coating is compatible with covered conductors
                Coated Conductor Dead-ends
              • Dielectric Wedge Dead-end
                • Ease of installation
                • Designed for specific conductor diameters
                • Compatible with all manufacturers’ Covered Aerial MV cable
                Dielectric Wedge Dead-end
              • Insulator Pins
                • Manufactured from cold rolled steel
                • Corrosion resistant
                • Compatible and interchangeable with Pin Insulators from all manufacturers
                Insulator Pins
              • Messenger Splices
                • Longitudinal holding strength equal to messenger
                • Uniform radial pressure exerted on the messenger
                • Designed for specific messenger sizes
                • Color coded for ease of selection in field
                Messenger Splices
              • Pole Extensions - 30
                • Manufactured from high-strength structural steel
                • Corrosion resistant
                • Drilled for use on standard utility poles
                • Used to provide additional pole height to allow for the installation of additional Covered Aerial MV cable circuit to the pole line
                Pole Extensions - 30"
              • Pole Extensions - >30
                • Manufactured from high-strength structural steel
                • Superior corrosion resistance
                • Pre-drilled for use on standard utility poles
                • Used to provide additional pole height to allow for the installation of Covered Aerial MV circuits to existing pole lines
                • The high-strength variations are available where double circuit or higher circuit loadings need to be acommodated. Two straight structural steel channel sections are used (not shown)
                Pole Extensions - >30"
              • Polymer Dead-end Insulators
                • High strength-to-weight ratio
                • Excellent hydrophobicity
                • Lightweight and shatter resistant
                • Low profile for compact construction
                Polymer Dead-end Insulators
              • Protective Guards
                • UV and track-resistant
                • Lightweight and shatter resistant
                • Incorporates tie hole for securing to messenger
                • Designed for specific messenger sizes
                • Can be cut to lenth in the field
                • Available in black or grey
                Protective Guards
              • Stripping Tool
                • Ease of use
                • Allow for both stripping at the end and mid-span
                • Designed for specific size, diameter and thickness of cables
                Stripping Tool
              • Roll-by Block
                • Swivel between messenger rollers and conductor rollers for better alignment during stringing
                • Non-slip cleat for easy attachment to the tag line
                • Individually guarded rollers to protect covered conductors
                • Available from Southwire with deposit
                Roll-by Block
              • Messenger Trolley and Tag Line
                • Designed for use with Roll-by Block to travel on messenger with pull rope
                • Counterweighted to prevent jumping off of messenger
                Messenger Trolley and Tag Line
              • Stringing Tools
                • Trains cable for ease of installation
                Stringing Tools
              • Splice Cover Kits
                • No torch required
                • Easily installed without any special tools
                • Maintains mechanical and electrical integrity of the cable
                • Compression splices not included
                Splice Cover Kits
              • Proof Positive® Copper
                • For uninsulated hook-ups, jumpers and grounds in substations
                • Unique serial number provides proof of ownership for traceability against theft
                • Available in medium-hard-drawn or annealed tempers
                Proof Positive® Copper
              • Bare Stranded Copper
                • For uninsulated hook-ups, jumpers and grounds in substations
                • Available in hard, medium-hard or soft (annealed) tempers
                Bare Stranded Copper
              • ACSR
                • Aluminum concentrically stranded around steel core
                • Cut to length available
                ACSR
              • AAC
                • Aluminum concentrically stranded
                • Cut to length available
                AAC
              • 1350-O Temper
                • Fully annealed aluminum rope lay stranded
                • Highly flexible
                • Cut to length available
                1350-O Temper
              • Fiber-in-Conduit
                • Fiber cable
                • HDPE conduit
                Fiber-in-Conduit
              • 35kV & 46kV Covered Aerial MV
                • Aluminum conductor
                • PE/XLPE inner covering
                • HDTRPE/XLPE outer covering
                35kV & 46kV Covered Aerial MV
              • Bare Copper
                • For uninsulated hook-ups, jumpers and grounds in substations
                • Available in hard, medium-hard or soft (annealed) temper
                Bare Copper
              • Proof Positive® Copper
                • Copper conductor
                • For uninsulated hook-ups, jumpers and grounds in substations
                • Unique serial number provides proof of ownership for traceability against theft
                • Available in medium-hard-drawn or annealed tempers
                Proof Positive® Copper
              • 2kV Aluminum RHH/RHW-2
                • Aluminum conductor
                • XLPE insulation
                2kV Aluminum RHH/RHW-2
              • 35kV XLPE MV Cables
                • Copper or aluminum conductor
                • XLPE insulation
                • PE jacket
                35kV XLPE MV Cables
              • CT1A-13ET
                • Aluminum conductor
                • EPR insulation
                • Copper tape shield
                • SIMpull® PVC jacket
                CT1A-13ET
              • EFC CT1-13ET
                • Copper conductor
                • EPR insulation
                • Copper tape shield
                • PVC jacket
                EFC CT1-13ET
              • CT1A-09ET
                • Aluminum conductor
                • EPR insulation
                • Copper tape shield
                • SIMpull® PVC jacket
                CT1A-09ET
              • EFC CT1-09ET
                • Copper conductor
                • EPR insulation
                • Copper tape shield
                • PVC jacket
                EFC CT1-09ET
              • RHH/RHW/USE (Copper) 600V
                • Copper conductor
                • XLPE insulation
                RHH/RHW/USE (Copper) 600V
              • RHH/RHW/USE (Aluminum) 600V
                • Aluminum conductor
                • XLPE insulation
                RHH/RHW/USE (Aluminum) 600V
              • Bare Copper
                • For uninsulated hook-ups, jumpers and grounds in substations
                • Available in hard, medium-hard or soft (annealed) temper
                Bare Copper
              • Proof Positive® Copper
                • Copper conductor
                • For uninsulated hook-ups, jumpers and grounds in substations
                • Unique serial number provides proof of ownership for traceability against theft
                • Available in medium-hard-drawn or annealed tempers
                Proof Positive® Copper
              • Fiber-in-Conduit
                • Fiber conductor
                • HDPE conduit
                Fiber-in-Conduit
              • Heliostat Cable: Branch
                • Tin coated copper conductor
                • XHHW insulation (power); XLPE insulation (communication)
                • PVC jacket
                Heliostat Cable: Branch
              • Heliostat Cable: Armored Trunk
                • Tin coated copper conductor
                • XHHW insulation (power); XLPE insulation (communication)
                • Armor-X, aluminum or galvanized steel interlocking armor
                • PVC jacket
                Heliostat Cable: Armored Trunk
              • 35kV & 46kV Covered Aerial MV
                • Aluminum conductor
                • PE/XLPE inner covering
                • HDTRPE/XLPE outer covering
                35kV & 46kV Covered Aerial MV
              • Copper RWU90
                • Copper conductor
                • XLPE insulation
                Copper RWU90
              • Aluminum RWU90
                • Aluminum conductor
                • XLPE insulation
                Aluminum RWU90
              • 25kV MV EPR Cable
                • Copper or aluminum conductor
                • EPR insulation
                • PE jacket
                25kV MV EPR Cable
              • 25kV MV XLPE Cable
                • Copper or aluminum conductor
                • XLPE insulation
                • PE jacket
                25kV MV XLPE Cable
              • 34-1 07XNS
                • 2.4kV. Copper Conductor. Thermosetting Conductor Shield.
                • Cross-linked Polyethylene (XLP) Insulation.
                • Limited to 2,400 Volts Maximum.
                34-1 07XNS
              • 34-2 09ENS/PVC 1c, EPR Heavy Wall, N/S, PVC Jacket
                • 2.4kV Type MV-90. Copper Conductor. Thermosetting Conductor Shield
                • EPR Insulation. Nonshielded. PVC Jacket
                • Limited to 2,400 Volts Maximum
                34-2 09ENS/PVC 1c, EPR Heavy Wall, N/S, PVC Jacket
              • 34-3 09ENS/LS 1c, EPR Heavy Wall, N/S, XLPO Jacket, CT Rated, LS Rated
                • 2.4kV Type MV-90. Copper Conductors. Thermosetting Conductor Shield.
                • EPR Insulation. Non-Shielded SOLONON™ (Cross-linked Polyolefin) LS, Oil Reistant II Jacket.
                • Sizes 1/0 AWG and larger listed for Limited Smoke, Sunlight Resistant, and for CT Use.
                • Limited to 2,400 Volts Maximum.
                34-3 09ENS/LS 1c, EPR Heavy Wall, N/S, XLPO Jacket, CT Rated, LS Rated
              • 34-4 CT09ENS 3c, EPR Heavy Wall, N/S, PVC Jacket
                • 2.4kV Type MV-105. Copper Conductors. Thermosetting Conductor Shield.
                • EPR Insulation. Non-Shielded.
                • Copper Ground Wire. Overall PVC Jacket.
                • Limited to 2,400 Volts Maximum.
                34-4 CT09ENS 3c, EPR Heavy Wall, N/S, PVC Jacket
              • Type TC VFD Power Cable
                • 600 Volt/2kV
                • XLP Insulation with Overall PVC Jacket
                • Sizes 8 AWG through 750 kcmil
                • 90°C Dry and 75°C Wet
                • Three Ground Wires
                • Suitable for VFD Applications
                Type TC VFD Power Cable
              • 32-1 1c XHHW-2, Power Cable, CT Rated
                • 600 Volts. Copper Conductor.
                • Flame Retardant Cross-Linked Polyethylene Insulation.
                • High-Heat, Moisture, and Sunlight Resistant, and rated for CT use.
                • SIM Technology for easier pulling.
                32-1 1c XHHW-2, Power Cable, CT Rated
              • 32-2 1c, RHH/RHW, Power Cable CT Rated
                • 600 Volts. Copper Conductor.
                • Flame Retardant Cross-Linked Polyethylene Insulation.
                • High-Heat, Moisture, and Sunlight Resistant, and rated for CT use.
                32-2 1c, RHH/RHW, Power Cable CT Rated
              • 32-3 1c XHHW/PVC Jacket, Power Cable, CT Rated
                • 600 Volts. Copper Conductor.
                • Flame Retardant Cross-Linked Polyethylene Insulation with Overall PVC Jacket.
                • High-Heat, Moisture, and Sunlight Resistant, and rated for CT use.
                •  Sizes 2/0 and Larger Rated FT-4.
                32-3 1c XHHW/PVC Jacket, Power Cable, CT Rated
              • 32-6 1c Al XHHW-2, Power Cable, CT Rated
                • 600 Volt. AlumaFlexTM Aluminum Alloy (AA-8176) Conductor.
                • Flame Retardant Cross-linked Polyethylene (XLP) Insulation.
                • High-Heat and Moisture and Sunlight Resistant and rated for CT use.
                32-6 1c Al XHHW-2, Power Cable, CT Rated
              • 32-10 3c, THHN/PVC, GW, Type TC Power Cable
                • Copper Conductors with PVC/Nylon Insulation Rated THHN.
                • Heat, Moisture and Sunlight Resistant PVC Outer Jacket.
                • Type TC Power Cable. 600 Volt. RoHS
                32-10 3c, THHN/PVC, GW, Type TC Power Cable
              • 32-11 4c, THHN/PVC, GW Type TC Power Cable
                • Type TC Power Cable. 600 Volt.
                • Copper Conductors with PVC/Nylon Insulation Rated THHN.
                • Overall Heat, Moisture and Sunlight Resistant PVC Jacket.
                • RoHS
                32-11 4c, THHN/PVC, GW Type TC Power Cable
              • 32-12 3c, XHHW/PVC, GW, Type TC Power Cable
                • Type TC Power Cable. 600 Volt. Copper Conductors.
                • XLP Insulated Singles Rated XHHW.
                • Heat, Moisture, and Sunlight Resistant. Overall PVC Jacket.
                • RoHS
                32-12 3c, XHHW/PVC, GW, Type TC Power Cable
              • 32-13 4c, XHHW/PVC, GW, Type TC Power Cable
                • Type TC Power Cable. 600 Volt. Copper Conductors.
                • XLP Insulated Singles Rated XHHW.
                • Heat, Moisture, and Sunlight Resistant. Overall PVC Jacket.
                • RoHS
                32-13 4c, XHHW/PVC, GW, Type TC Power Cable
              • 32-16 EPR / Solonon 600 Volt RHH / RHW-2 / USE-2
                • 600 Volt. Copper Conductor. EPR Insulation.
                • SOLONON®(Cross-Linked Polyolefin) Jacket.
                • Sizes AWG 1/0 and Larger Listed for Limited Smoke, for CT use and Sunlight Resistant.
                • RoHS
                32-16 EPR / Solonon 600 Volt RHH / RHW-2 / USE-2
              • 32-18 Type TC Power 3c Cable XHHW-Solonon Jacket
                • Type TC Power Cable. 600 Volt. Copper Conductors.
                • XLP Insulated Singles Rated XHHW.
                • Three Conductors With Ground. Overall SOLONON Jacket.
                • Heat, Moisture, and Sunlight Resistant.
                32-18 Type TC Power 3c Cable XHHW-Solonon Jacket
              • 32-19 Type TC Power 4c Cable XHHW-Solonon Jacket
                • Type TC Power Cable.
                • 600 Volt.
                • Copper Conductors.
                • XLP Insulated Singles Rated XHHW.
                • Four Conductors With Ground.
                • Overall SOLONON Jacket. Heat, Moisture, and Sunlight Resistant.
                32-19 Type TC Power 4c Cable XHHW-Solonon Jacket
              • 31-1 THHN Type TC Control Cable
                • Type TC Control Cable.
                • 600 Volt.
                • Copper Conductors.
                • PVC/Nylon Insulated Singles Sizes 16 AWG through 10 AWG.
                • Overall PVC Jacket.
                • Heat, Moisture and Sunlight Resistant.
                31-1 THHN Type TC Control Cable
              • 31-3 XHHW/PVC Type TC Control Cable
                • Type TC Control Cable.
                • 600 Volt.
                • Copper Conductors.
                • FR-XLP Insulated Singles Type XHHW rated VW-1.
                • Overall PVC Jacket.
                • Heat, Moisture and Sunlight Resistant.
                31-3 XHHW/PVC Type TC Control Cable
              • 31-5 Type TC Control Cable XHHW-Solonon Jacket
                • Type TC Control Cable. 600 Volt. Copper Conductors.
                • FR-XLP Insulated Singles Type XHHW rated VW-1.
                • Overall SOLONON Jacket.
                • Heat, Moisture and Sunlight Resistant.
                31-5 Type TC Control Cable XHHW-Solonon Jacket
              • 31-6 Instrumentation TC Cable
                • Instrumentation Cable. 600 Volt Type Cable.
                • PVC/Nylon Insulated Singles, Sizes 18 AWG or 16 AWG, 90°C.
                • PVC Jacket. RoHS
                31-6 Instrumentation TC Cable
              • CSA TECK 90 600v Control Cable
                • 600V MULTI-CONDUCTOR
                • #14 TO #10 AWG COPPER
                • XLPE INSULATION
                • ALUMINUM INTERLOCKED ARMOUR
                • INNER AND OUTER PVC JACKETS
                • RATED HL (HAZARDOUS LOCATIONS)
                CSA TECK 90 600v Control Cable
              • CSA TECK 90 1000v Control Cable
                • 1000V MULTI-CONDUCTOR
                • #14 TO #10 AWG COPPER
                • XLPE INSULATION
                • ALUMINUM INTERLOCKED ARMOUR
                • INNER AND OUTER PVC JACKETS
                • RATED HL (HAZARDOUS LOCATIONS)
                CSA TECK 90 1000v Control Cable
              • CSA TECK 90 1000V Power Cable
                • T90
                • 1000V MULTI-CONDUCTOR
                • #8 AWG & UP COPPER
                • XLPE INSULATION
                • ALUMINUM INTERLOCKED ARMOUR
                • INNER AND OUTER PVC JACKETS
                • RATED HL (HAZARDOUS LOCATIONS)
                CSA TECK 90 1000V Power Cable
              • CSA TECK 90 CU 3c 90 EPR 5000V
                • 5KV TECK 90
                • 5000V - Non-shielded
                • EPR insulated power cable
                • CSA approved armoured cable
                • Industrial and commercial
                • Medium voltage
                • FT4, -40C, HL and 90°C rated
                CSA TECK 90 CU 3c 90 EPR 5000V
              • CSA TECK 90 TR-XLPE 3c 5000v
                CSA TECK 90 TR-XLPE 3c 5000v
              • American Mustang Type MP-GC XLP-PVC
                • 5-15 KV. Copper Conductors
                • XLP Insulation. Copper Tape Shield.
                • PVC Jacket. 4 AWG-500 kcmil.
                • 50° C to 90° C
                American Mustang Type MP-GC XLP-PVC
              • American Mustang ®  Type SHD-GC
                • 2-15 KV. Tinned Copper Conductors
                • EPR Insulation. Tinned Copper Braid Shield.
                • Extra Heavy Duty CPE Jacket.
                • 14 AWG-500 kcmil. –50° C to 90° C
                American Mustang ® Type SHD-GC
              • American Mustang® Type MP-GC EPR

                • 5-15 KV. Copper Conductors
                • EPR Insulation. Copper Tape Shield.
                • CPE Jacket. 4 AWG-500 kcmil.
                • –50° C to 90° C
                American Mustang® Type MP-GC EPR
              • Industrial Type W

                • 2000 Volt. Flexible Copper Conductors.
                • EPDM Insulation. Heavy Duty CPE Jacket
                • Wet or dry 90°C to -40°C. 8 AWG-500 kcmil
                Industrial Type W
              • Industrial Type G-GC
                • 2000 Volt. 3 Flexible Copper Conductors.
                • EPDM Insulation. Heavy Duty CPE Jacket
                • Ground Check and 2 Insulated Ground Wires
                • Wet or dry 90°C to -40°C. 8 AWG-500 kcmil
                Industrial Type G-GC
              • Industrial Type G

                • 2000 Volt. 4 Flexible Copper Conductors.
                • EPDM Insulation. Heavy Duty CPE Jacket
                • 4 Insulated Ground Wires
                • Wet or dry 90°C to -40°C. 8 AWG-500 kcmil
                Industrial Type G
              • Powerflex 90 Type G or G-GC Round
                • 2000 Volt. Portable Power Cable
                • Tinned Copper Conductors
                • EPR Insulation
                • Extra Heavy Duty CPE Rubber Jacket
                • Wet or dry 90°C to -50°C.
                • 8 AWG-500 kcmil
                Powerflex 90 Type G or G-GC Round
              • Powerflex 90 Type G or G-GC Flat
                • Portable Power Cable. 2000 Volt.
                • Tinned Copper Conductors. EPR Insulation.
                • CPE Rubber Jacket . 6 - 1 AWG.
                • Wet or Dry. -50°C to 90°C.
                Powerflex 90 Type G or G-GC Flat
              • Powerflex® Type W Flat
                • 2000 Volts.
                • Tinned Copper Conductors
                • EPR Insulation. CPE Jacket
                • Wet or dry 90°C to -50°C
                Powerflex® Type W Flat
              • Powerflex® Type W Round
                • 2000 Volt.
                • Tinned Copper EPR Insulation.
                • Extra Heavy Duty CPE Rubber Jacket
                • Wet or dry 90°C to -50°C.
                • 8 - 4/0 AWG
                Powerflex® Type W Round
              • Powerflex 90 Type SHD-GC Shovel & Dragline Cable Round

                • 2000 Volt. Tinned Copper Conductors
                • EPR Insulation. Tinned Copper Braid Shield.
                • Integral Fill Inner Jacket. Extra Heavy Duty CPE Jacket.
                • 4 AWG-500 kcmil. –50° C to 90° C
                Powerflex 90 Type SHD-GC Shovel & Dragline Cable Round
              • American Mustang Type W Portable Power Cable
                • 8 AWG - 500 kcmil. 600/2000V
                • 90°C Wet or Dry. RHH, RHW-2
                • Indoor/Outdoor
                American Mustang Type W Portable Power Cable
              • Remote & Drill Cord
                • 600 Volt. Copper Conductors
                • EPR Insulation. Neoprene Outer Jacket
                • 14-10 AWG. 90° C
                Remote & Drill Cord
              • TPU Type SHD-GC Portable Power Cable
                • EPDM Insulation. Copper Braid Shield
                • 4 AWG - 400 kcmil. 8000 Volts
                • 90°C - -50°C
                TPU Type SHD-GC Portable Power Cable
              • AL Mobile Home Feeder
                • Underground Service Entrance Cable
                • 600 Volt
                • AlumaFlex™ Aluminum Alloy (AA-8176) Conductors
                • Cross-linked Polyethylene (XLP) Insulation
                • Sunlight Resistant
                AL Mobile Home Feeder
              • AL RHH/RHW/USE
                • Underground Service Entrance Cable
                • 600 Volt
                • AlumaFlex™ Aluminum Alloy (AA-8176) Conductor
                • Cross-linked Polyethylene (XLP) Insulation
                • High-Heat, Moisture, and Sunlight Resistant
                AL RHH/RHW/USE
              • AL SEU/SER
                • Type SE, Style R and Type SE, Style U
                • Service Entrance Cable
                • 600 Volt
                • AlumaFlex™ Aluminum Alloy (AA-8176) Conductors
                • Individual Conductors Rated XHHW-2 or TYPE THWN
                • AlumaFlex™ Aluminum Alloy Neutral
                • Sunlight Resistant
                • Jacket and Individual Conductors
                AL SEU/SER
              • AL XHHW
                • 600 Volt
                • AlumaFlex™ Aluminum Alloy (AA-8176) Conductor
                • Cross-linked Polyethylene (XLP) Insulation
                • High-Heat and Moisture Resistant
                • Black Sizes 2 AWG and Larger Sunlight Resistant
                AL XHHW
              • 1050 ALLOY
                • Non-heat-treatable alloy
                • Principle alloying elements: none (primary trace elements: iron and silicon)
                • Density: 2.705 g/cm3
                • Standard diameter:* .375" (9.5mm)
                • Tempers supplied: F (as Fabricated)

                 

                1050 ALLOY
              • 1100 ALLOY
                • Non-heat-treatable alloy
                • Principle alloying elements: none (primary trace elements: iron, silicon and copper)
                • Density: 2.71 g/cm3
                • Standard diameter:* .375," .500" (9.5mm, 12.7mm)
                • Tempers supplied: F (as Fabricated)
                1100 ALLOY
              • 1350 ALLOY (EC)
                • Non-heat-treatable alloy
                • Principle alloying elements: none (primary trace elements: iron and silicon)
                • Density: 2.705 g/cm3
                • Standard diameter:* .375," .500," .875" (9.5mm, 12.7mm, 22.2mm)
                • Tempers supplied: O (Annealed), H (Strain Hardened)
                1350 ALLOY (EC)
              • 5052 ALLOY
                • Non-heat-treatable alloy
                • Principle alloying elements: magnesium and chromium
                • Density: 2.68 g/cm3
                • Standard diameter:* .375" (9.5mm)
                • Tempers supplied: F (as Fabricated)
                5052 ALLOY
              • 5154A ALLOY
                • Non-heat-treatable alloy
                • Principle alloying elements: magnesium
                • Density: 2.60 g/cm3
                • Standard diameter:* .375" (9.5mm)
                • Tempers supplied: F (as Fabricated)
                5154A ALLOY
              • 6063 ALLOY
                • Heat-treatable alloy
                • Principle alloying elements: magnesium and silicon
                • Density: 2.70 g/cm3
                • Standard diameter:* .375" (9.5mm), 500" (12.7mm)
                • Tempers supplied: F (as Fabricated), T4 (Thermally Treated)
                6063 ALLOY
              • 6101 ALLOY
                • Heat-treatable alloy
                • Principle alloying elements: magnesium and silicon
                • Density: 2.7 g/cm3
                • Standard diameter:* .375," .500" (9.5mm, 12.7mm)
                • Tempers supplied: F (as Fabricated), T4 (Thermally Treated)
                6101 ALLOY
              • 6201 ALLOY
                • Heat-treatable alloy
                • Principle alloying elements: magnesium and silicon
                • Density: 2.69 g/cm3
                • Standard diameter:* .375," .500" (9.5mm, 12.7mm)
                • Tempers supplied: F (as Fabricated), T4 (Thermally Treated)
                6201 ALLOY
              • DEOX
                • Non-heat-treatable alloy
                • Principle alloying elements: none (primary trace elements: magnesium, iron and silicon)
                • Density: 2.70 g/cm3
                • Standard diameter:* .375" (9.5mm), 500" (12.7mm), .6875" (17.5mm)
                • Tempers supplied: F
                DEOX
              • Temper Information
                Temper Information
              • Triple E ™ Aluminum Alloy
                • Non-heat-treatable alloy
                • Principle alloying elements: iron
                • Density: 2.71 g/cm3
                • Standard diameter:* .375," .500" (9.5mm, 12.7mm)
                • Tempers supplied: H (Strain Hardened)
                Triple E ™ Aluminum Alloy
              • XLPE & IRXLPE Lead
                • Meets 3000 Hour Long Term Aging
                • Flame Resistant
                • Resistant to Automotive Fluids
                • Ozone Resistant
                • Hot Water Resistant
                • Resistant to Tape Abrasion and Scrape Abrasion
                • Resistant to Temperature and Humidity Cycling
                XLPE & IRXLPE Lead
              • PVC Automotive Lead wire
                • 85°C & 100°C PVC Thin Wall & Standard Wall
                • For use in harnesses made for all types of land vehicles
                • Can be used in systems with voltages of 60 VDC and 25 VAC
                • Can be used in systems with voltages of 600 VDC and 600 VAC
                PVC Automotive Lead wire
              • HDT/GPT/TWP
                • Stranded Bare or Copper Conductors
                • PVC Insulation
                • 85°C, 60 Volts
                HDT/GPT/TWP
              • SXL/GXL/TXL
                • Stranded Bare or Tinned Copper Conductors with Cross-linked Polyethylene Insulation
                • 125°C, 50 Volts
                SXL/GXL/TXL
              • SGT/SGR/SGX Battery Cable
                • Stranded Bare Copper with PVC, Rubber, TPR or Cross-link Insulation
                • 85°C, 90°C, 125°C, 60 Volts
                SGT/SGR/SGX Battery Cable
              • Booster Cable
                • Stranded Bare Copper with PVC, Rubber or TPR Insulation
                • 90°C, 50 Volts
                • 60°C, 105°C
                Booster Cable
              • Trailer Cable
                • Stranded Bare Copper Conductors with PVC, Rubber or TPR Insulation
                • Twisted with Overall Jacket
                • 60°C, 90°C, 105°C -40°C, -65°C
                Trailer Cable
              • Brake Cable
                • Stranded Bare or Tinned Copper Conductors
                • 60°C, 105°C, 50 Volts
                Brake Cable
              • Annunciator (Bell) Wire
                • Soft Bare Copper Conductors
                • Thermoplastic Insulation
                • Multiple Conductors are Twisted
                • 60°C
                • 30 Volts
                Annunciator (Bell) Wire
              • AWM 3321
                • Solid or Stranded Soft Bare or Tinned Copper Conductors
                • XLPE Insulation
                • 150°C
                • 600 Volts
                AWM 3321
              • Bare Copper
                • Bare Copper Conductor
                • Solid and Stranded
                Bare Copper
              • CL 1251/AWM 3173
                • Solid or Stranded Soft Bare or Tinned Copper Conductors
                • XLPE Insulation 
                • 125°C
                • 600 Volts
                CL 1251/AWM 3173
              • Fire Alarm Cable (FAS)
                • Solid or Stranded Bare Copper Conductors
                • 105°C
                • 300 Volts
                Fire Alarm Cable (FAS)
              • HLX01-POS/SPOS
                • 600 V Type MC-HL Cable
                • ARMOR-X® and ARMOR-Xtra™ HL
                • PVC/Nylon Insulated Singles, Sizes 18 AWG or 16 AWG, 90°C
                • Continuous Corrugated Aluminum Armor with -40°C PVC Jacket
                HLX01-POS/SPOS
              • HLX01XXH
                • 600 V Type MC-HL Control
                • ARMOR-X® and ARMOR-Xtra™ HL
                • XLP Insulated, 90°C
                • Continuous Corrugated Aluminum Armor with -40°C PVC Jacket
                HLX01XXH
              • LVT
                • Solid or Stranded Soft Bare Copper Conductors
                • 60°C Only
                • 30 Volts
                LVT
              • RHH/RHW/USE
                • Underground Service Entrance Cable
                • 600 Volt
                • Copper Conductors
                • Cross-Linked Polyethylene (XLP) Insulation
                • High-Heat, Moisture, and Sunlight Resistant
                • Sizes 6 Through 4/0 AWG Also Rated SIS
                RHH/RHW/USE
              • Romex® SIMpull® Type NM-B
                • Non-metallic Sheathed Cable
                • 600 Volt
                • Copper Conductors
                • Color-Coded Jacket SIM Jacket™
                • Construction Designed for Easier Pulling
                • Four Conductor Available With Two Neutrals
                • Pulls Faster
                • Strips Easier
                • Reduced Burn-Thru
                • Tear Resistant
                Romex® SIMpull® Type NM-B
              • Romex® SIMpull® Type NMD90
                • Non-metallic Sheathed Cable
                • 300 Volts
                • Copper Conductors
                • SIM Jacket™ Construction Designed for Easier Pulling
                • Pulls Faster
                • Strips Easier
                • Reduced Burn-Thru
                • Tear Resistant
                Romex® SIMpull® Type NMD90
              • SEU/SER/SE
                • Service Entrance Cable, Type SE, Style U
                • 600 Volt
                • Copper Conductors Individual Conductors
                • Rated XHHW-2 or THHN/THWN
                • Copper Concentric Neutral
                • Jacket and Individual Conductors Sunlight Resistant
                SEU/SER/SE
              • TEW/AWM 1015/1019/1020/1230 MTW
                • 600 V
                • 105°C Dry
                • 60°C Moisture Resistant
                • Solid or Stranded Bare, Tinned, or Prefused Copper
                • Thermoplastic Insulation
                TEW/AWM 1015/1019/1020/1230 MTW
              • TFFN/TFN/TEWN
                • 600 Volt
                • Copper Conductor
                • Thermoplastic Insulation/Nylon Sheath Heat, Moisture, Oil, and Gasoline Resistant1
                • Also Rated MTW and 105°C AWM
                • Also Available, TFN
                TFFN/TFN/TEWN
              • THHN/THWN/TWN75/T90
                • 600 Volts
                • Copper Conductor
                • Thermoplastic Insulation/Nylon Sheath Heat, Moisture, Gasoline, and Oil Resistant1
                • Sizes 8 AWG and Larger Rated THWN-2 All Stranded Sizes Rated MTW and THWN
                • Sizes 14 Through 6 AWG Rated AWM (105°C) Sizes 14 Through 1 AWG Rated VW-1
                • Size 1/0 AWG and Larger Listed for CT Use Black Size 2 AWG and Larger Listed Sunlight-Resistant
                THHN/THWN/TWN75/T90
              • TR64/AWM 1007
                • Solid or Stranded Tinned Copper Conductors
                • PVC Insulation
                • 90°C
                • 300 Volts
                TR64/AWM 1007
              • UF-B
                • Underground Feeder and Branch Circuit Cable
                • 600 Volt
                • Copper Conductors
                • Sunlight, Moisture, and Fungus Resistant Overall PVC Jacket
                UF-B
              • XHHW
                • 600 Volt
                • Copper Conductor
                • Cross-Linked Polyethylene (XLP) Insulation
                • High-Heat and Moisture Resistant
                • Sizes 14 Through 8 AWG Also Rated SIS
                • Black Sizes 2 AWG and Larger Sunlight Resistant
                XHHW
              • Thermostat Wire Plenum Rated
                • Rated 300 Volts
                • Sunlight-Resistant -20°C to +60°C
                • 18 Gauge Copper Conductors
                Thermostat Wire Plenum Rated
              • Blasting Cable
                • Stranded Copper Conductors With Neoprene Rubber Insulation
                • Two Conductor Twisted With No Jacket
                • 60°C
                Blasting Cable
              • Coaxial Cable
                Coaxial Cable
              • PXT / PXWT / XTW / CXWT
                • Bare Stranded Copper
                • Laid Parallel With PVC Insulation
                • 60°C, 125 Volts - PXT
                • 300 Volts - PXWT (-40°C)
                PXT / PXWT / XTW / CXWT
              • LVLL/ULEC Landscape Lighting
                • Rated 150 Volts Rated -20°C to +60°C
                • Approved for Outdoor Use (Sunlight Resistant) Suitable for Direct Burial
                • Stranded Copper Conductors
                • Black PVC Insulation/Jacket
                LVLL/ULEC Landscape Lighting
              • Submersible Pump Cable
                • Solid or Stranded Bare Copper Conductors
                • Individuals PVC Insulation
                • 3 or 4 Twisted Conductors
                • 600 Volts, Maximum 60°C
                • Sunlight & Weather Resistant
                Submersible Pump Cable
              • SPT-1/SPT-2/SPT-3 Lamp Cord
                • Rated 300 Volts Rated 105°C
                • Stranded Copper Conductors Yellow or Black Jacket
                • Thermoplastic Insulation
                SPT-1/SPT-2/SPT-3 Lamp Cord
              • Irrigation Cable
                • Solid Bare Copper
                • PVC Insulation
                • Twisted Without Fillers
                • Overall PVC Jacket
                • 60°C
                Irrigation Cable
              • Speaker Wire
                • Bare or Tinned Stranded Copper
                • Parallel Clear or Opaque PVC Insulation or EPDM Inliners
                • Two Copper Conductors
                • 60°C/105°C
                Speaker Wire
              • Thermostat Wire
                • Rated 150 Volts
                • Sunlight-Resistant -20°C to +60°C
                • 18 and 20 Gauge Copper Conductors
                Thermostat Wire
              • SIS
                • 600 Volt
                • Tinned Copper Conductor
                • 90oC Cross-linked Polyethylene (XLP) Insulation
                • Sunlight Resistant
                • UL Listed. CSA Listed
                • Meets Flame Tests FT1 & FT2
                • Rated VW-1
                SIS
              • Type Heavy Duty SC Entertainment Cable
                • 600 Volts
                • Extra Flexible Copper Conductors
                • Water and Sunlight Resistant
                • Designed to Withstand Severe Environmental Conditions
                • -40°C to 105°C
                • Listed for Indoor or Outdoor Use
                • Flame Retardant
                • Provides Flexibility, Resistance to Oil, Solvents, Ozone, Aging and Abrasion
                Type Heavy Duty SC Entertainment Cable
              • Viper ® Type SOOW
                • 600 Volts
                • Flexible Stranding
                • Flame & Ozone Resistant
                • Black Jacket
                • -40°C to 90°C
                • RoHS Compliant
                • UL Listed & CSA Certified for Indoor & Outdoor Use
                • Provides Premium Oil Resistance & High Flexibility
                • Excellent Abrasion Resistance
                • NEC, Rated Extra-Hard Usage
                Viper ® Type SOOW
              • Viper ® Type SJOOW
                • 600 Volts
                • Good Tensile Strength, Elongation & Aging Characteristics
                • Black Jacket
                • -40°C to 90°C
                • RoHS Compliant
                • UL Listed & CSA Certified for Indoor & Outdoor Use
                • Provides Premium Oil Resistance, Water Resistance & High Flexibility
                • Excellent Abrasion Resistance
                • NEC, Rated Extra-Hard Usage
                Viper ® Type SJOOW
              • Type W Portable Power Cable
                • 2000 Volts
                • -40°C to 90°C
                • Oil & Sunlight Resistance
                • Single Conductors Listed as Type RHH/RHW-2
                • UL Listed & c(UL) Listed
                • CSA Certified
                • MSHA Approved
                • RoHS Compliant
                Type W Portable Power Cable
              • Low Capacitance Multi-Conductor AWM Styles - Rated CM/CL3
                • Rated for <150 Volt
                • Low Capacitance, High Impedance
                • Data Cable for Sensing, Communications and Control
                • For Use in All Areas Other than Plenums
                • Flexible
                • Shielded
                • Sizes 18 to 22 AWG Single Conductors
                Low Capacitance Multi-Conductor AWM Styles - Rated CM/CL3
              • RS-485 Low Capacitance Computer Cable - Rated CM
                • Rated for <150 V
                • Low Capacitance, High Impedance, RS-485 Applications
                • Data Cable for Sensing, Communications and Control
                • For Use in All Areas Other than Plenums
                • Flexible
                • Shielded
                • Size 24 AWG Pairs
                RS-485 Low Capacitance Computer Cable - Rated CM
              • RS-232 Low Capacitance Computer Cable - Rated CM
                • Rated for <150 V
                • Low Capacitance, High Impedance, RS-232 Applications
                • Data Cable for Sensing, Communications and Control
                • For Use in All Areas Other than Plenums
                • Flexible
                • Shielded
                • Size 24 AWG Pairs
                RS-232 Low Capacitance Computer Cable - Rated CM
              • Encoder Cable
                • Rated for <150 V
                • Low Capacitance, High Impedance, RS-422 Applications
                • Data Cable for Sensing, Communications and Control
                • For Use in All Areas Other than Plenums
                • Flexible
                • Shielded
                • Size 24 AWG