Primary Distribution Products
-
-
Primary UD Sentry Cable-In-Conduit
High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable. Standard Wall, Schedule 40 & 80, SDR 13.5 & 11 Wall Thicknesses.
- High-Density Polyethylene (HDPE) Conduit with Pre-Installed Cable.
- Standard Wall, Schedule 40 & 80, SDR 13.5 & 11 Wall Thicknesses.
-
15kV HI-DRI UD
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
-
25kV HI-DRI UD
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
-
28kV HI-DRI UD
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
-
35kV HI-DRI UD
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
-
15kV HI-DRI Jacketed
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
- Polyethylene Jacket.
-
25kV HI-DRI Jacketed
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
- Polyethylene Jacket.
-
28 kV HI-DRI Jacketed
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
- Polyethylene Jacket.
-
35 kV HI-DRI Jacketed
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
- Polyethylene Jacket.
-
15kV-35kV LCT Shielded
- Aluminum or Copper Conductors.
- Tree-Retardant Cross-linked Polyethylene (TRXLP) Insulation.
- Copper Longitudinal Corrugated Tape (LCT) Shield.
-
15 kV PowerGlide MV Primary UD Cable
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
- Engineered PowerGlide™ Polyethylene Jacket.
-
25 kV PowerGlide MV Primary UD Cable
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
- Engineered PowerGlide™ Polyethylene Jacket.
-
28 kV PowerGlide MV Primary UD Cable
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
- Engineered PowerGlide™ Polyethylene Jacket.
-
35 kV PowerGlide MV Primary UD Cable
- Aluminum or Copper Conductor.
- TRXLP Insulation.
- Bare Copper Concentric Neutrals.
- Engineered PowerGlide™ Polyethylene Jacket.
-
LCT Shielded PowerGlide MV Primary UD Cable
- Aluminum or Copper Conductors.
- TRXLP Insulation.
- Copper Longitudinal Corrugated Tape Shield (LCT).
- Engineered PowerGlide™ Polyethylene Jacket.
-
Primary UD Sentry Cable-In-Conduit
-
-
ACSR
- Aluminum Conductor.
- Steel Reinforced 1.
- Bare.
-
ACSR/AW
- Aluminum Conductor.
- Aluminum-Clad Steel Reinforced.
- Bare.
-
ACAR
- Aluminum Conductor.
- Aluminum Alloy Reinforced.
- Bare.
-
ACSR/TW
- Aluminum Conductor.
- Steel Reinforced.
- Trapezoidal Shaped Aluminum Strands.
- Bare.
-
AAAC-6201
- All Aluminum Alloy Conductor.
- Bare.
-
AAC
- All Aluminum Conductor.
- Bare.
-
AAC/TW
- All Aluminum Conductor.
- Trapezoidal Shaped Conductors.
- Bare.
-
Motion-Resistant Conductor
ACSR Motion-Resistant Conductor. Bare Aluminum Conductor, Steel Reinforced.
- ACSR Motion-Resistant Conductor.
- Bare Aluminum Conductor, Steel Reinforced.
-
VR2 Cable
- Vibration-Resistant.
- Bare Aluminum Cable.
- Available in AAC and ACSR Constructions.
-
ACSR
-
-
15-2 15kV Spacer Cable-Tree Wire
- Aluminum Conductor.
- HD Polyethylene or Crosslinked Polyethylene Covering.
-
15-2 15kV Spacer Cable-Tree Wire